NextSDS Logo
Safety Data Sheet NL

PRISULON CM 70

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PRISULON CM 70

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Textielhulpmiddel

Manufacturers & Suppliers

C

CHT R. BEITLICH GMBH

manufacturer

Bismarckstraße 102, D-72072 Tübingen

++49-7071-154-0

C

CHT BELGIUM NV

distributor

President Kennedypark 39, B-8500 Kortrijk

056-20 31 14

Emergency Contacts

CHT R. BEITLICH GMBH

+7071-154-0

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemische karakterisering: CAS-Nr. omschrijving

Chemical Name CAS Number Concentration Hazardous
Hydroxyethylcellulose EC: 232-674-9 9004-62-0 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht toevoeren; bij klachten arts opzoeken

Skin contact

Onmiddellijk met veel water afwassen. Wanneer de huid geïrriteerd blijft, een dokter opzoeken.

Eye contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion

Mond en keelholte met water uitspoelen. Als de klachten niet verminderen, een arts consulteren

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, schuim, droog blusmiddel

Unsuitable media

water (papvorming - gevaar voor uitglijden)

Specific hazards

Bij brand en smeulend vuur komen stoffen vrij die schadelijk zijn voor de gezondheid.

Firefighter Protection

Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Indringen verhinderen in de aarde, waterlopen en afvoerleidingen.

Cleanup methods

Mechanisch opnemen. Niet met water of waterachtige reinigingsmiddelen wegspoelen.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Stofvorming vermijden. Zorgen voor een goede ventilatie/afzuiging op de arbeidsplaatsen.

Storage

Koel en droog bewaren in goed gesloten vaten. Steeds in tanks/containers bewaren, die overeenstemmen met de voorwaarden van de originele verpakkingen.

Fire prevention

Ontstekingsbronnen op afstand houden - niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
ca. 450 kg/m³
Odor
reukloos
Odor Threshold
---
Freezing Point
---
Evaporation Rate
niet toepasselijk
State Under Standard Conditions
---
Metal Corrosion
---
Relative Evaporation Rate
---
Form
Granulaat
Decomposition Temperature
> 200°C
Density
niet bepaald
Colour
wit - geelachtig
Colour Intensity
---
Flammability
Na ontvlamming volgt een rustig doorbranden. Brandoverslag mogelijk.
Auto Ignition Temperature
> 359°C
Upper Explosive Limit
---
Solubility In Water
dikt aan
Solubility In Fat
---
Vapor Pressure
niet toepasselijk
Ph
ca. 7
Solidification Point
---
Voc Content
---
Molecular Weight
---
Properties Status
---
Lower Explosive Limit
---
Crystallisation Point
---
Partition Coefficient
niet toepasselijk
Flash Point
niet bruikbaar
Vapor Density
---
Physical State Data
solid
Cloud Point
---
Physical State
Granulaat
Relative Density
---
Boiling Point
niet bepaald
Kinematic Viscosity
---
Appearance
---
Dynamic Viscosity
300 mPas (2%ige waterige oplossing)
Explosive Limits
---
Solubility
---
Melting Point
niet bepaald
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen ontbinding bij gebruik volgens het voorschrift.

Avoid

Ontbindt bij temperaturen boven 200 °C.

Decomposition

Geen gevaarlijke ontbindingsproducten bij deskundig stockeren en hanteren. Bij een brand kan vrijkomen: zie hoofdstuk 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PRISULON CM 70?

The signal word is no signal word.

What is the physical form of PRISULON CM 70?

PRISULON CM 70 is a granulaat with wit - geelachtig color. It has reukloos odor.

What is PRISULON CM 70 used for?

Textielhulpmiddel

What is the melting point of PRISULON CM 70?

The melting point is niet bepaald and the boiling point is niet bepaald.