NextSDS Logo
Safety Data Sheet NL

REDULIT C

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
REDULIT C

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Textielhulpmiddel

Manufacturers & Suppliers

C

CHT R. BEITLICH GMBH

manufacturer

Bismarckstraße 102, D-72072 Tübingen

++49-7071-154-0

C

CHT BELGIUM NV

national supplier

President Kennedypark 39, B-8500 Kortrijk

056-20 31 14

Emergency Contacts

CHT R. BEITLICH GMBH

+7071-154-0

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Sulfinezuurderivaat

Chemical Name CAS Number Concentration Hazardous
Natriumhydroxymethansulfinaat EC: 205-739-4 149-44-0 50 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht toevoeren; bij klachten arts opzoeken

Skin contact

Onmiddellijk met water en zeep afwassen en goed naspoelen. Wanneer de huid geïrriteerd blijft, een dokter opzoeken.

Eye contact

Ogen met open ooglid een aantal minuten onder stromend water afspoelen en aansluitend arts consulteren.

Ingestion

Mond spoelen en overvloedig water laten drinken. Geen braken teweegbrengen en onmiddellijk bijstand van arts inroepen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, schuim, droog blusmiddel

Specific hazards

Bij brand en smeulend vuur komen stoffen vrij die schadelijk zijn voor de gezondheid.

Instructions

Bij brand, de rook en dampen niet inademen. Vrijkomende dampen neerslaan met een waternevel.

Firefighter Protection

Onafhangelijk van de luchtcirculatie, ademhalingsapparaat en veiligheidspak tegen scheikundige producten dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Indringen verhinderen in de aarde, waterlopen en afvoerleidingen. Plaatselijke wettelijke voorschriften in acht nemen.

Cleanup methods

Mechanisch opnemen.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Stofvorming vermijden. Tanks ondoordringbaar gesloten houden.

Storage

Koel en droog bewaren in goed gesloten vaten. Verpakkingen steeds luchtdicht gesloten stockeren. Tegen luchtvochtigheid en water beschermen. Ver houden van warmtebronnen.

Fire prevention

Ontstekingsbronnen op afstand houden - niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Geen aanvullende gegevens. Zie 7.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Poeder, wit
Colour
wit
Colour Intensity
---
Form
Poeder
Odor
karakteristiek
Odor Threshold
---
Ph
9 - 11
Melting Point
niet bepaald
Boiling Point
niet bepaald
Flash Point
> 100°C (DIN 51758)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
niet toepasselijk
Vapor Pressure
niet toepasselijk
Vapor Density
---
Relative Density
---
Bulk Density
900 - 950 kg/m³
Density
niet toepasselijk
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
> 50°C
Decomposition Temperature
> 50°C
Solubility
---
Partition Coefficient
niet toepasselijk
Solubility In Water
500 - 600 g/l
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
niet bepaald
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen ontbinding bij gebruik volgens het voorschrift.

Hazardous reactions

Bij inwerking van zuren ontstaat zwaveldioxyde.

Avoid

Geen ontbinding bij gebruik volgens het voorschrift.

Incompatible

Zuren, oxidatiemiddelen

Decomposition

Geen gevaarlijke ontbindingsproducten bij deskundig stockeren en hanteren. Bij een brand kan vrijkomen: zie hoofdstuk 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for REDULIT C?

The signal word is na: r-phrases.

What is the physical form of REDULIT C?

REDULIT C is a solid appearing as poeder, wit with wit color. It has karakteristiek odor.

What is REDULIT C used for?

Textielhulpmiddel

What is the melting point of REDULIT C?

The melting point is niet bepaald and the boiling point is niet bepaald.