NextSDS Logo
Safety Data Sheet NL

Thermbond Formula Activator

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Thermbond Formula Activator
Product Code
F-ACT

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Activator

Manufacturers & Suppliers

S

Stellar Materials Incorporated

manufacturer

7777 Glades Road Suite 200, Boca Raton, FL 33434, U.S.A.

Emergency Contacts

Stellar Materials Incorporated

+1 (561) 330-9300

during normal opening hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Bijtend

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 Veroorzaakt ernstige brandwonden en oogletsel.

Precautionary Statements

P260 Stof/rook/gas/nevel/damp/spuitnevel niet inademen.
P303 + P361 + P353 BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken - huid met water afspoelen/afdouchen.
P305 + P351 + P338 BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
P310 Onmiddellijk een ANTIGIFCENTRUM of een arts raadplegen.
P405 Achter slot bewaren.
P501 De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
phosphoric acid --- 47 - 54% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

Skin contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

Eye contact

Ogen met open ooglid een aantal minuten onder stromend water afspoelen en dokter raadplegen.

Ingestion

Drink zeer veel water en voer verse lucht aan. Onmiddellijk een dokter waarschuwen.

Immediate Medical Attention

Onmiddellijk een dokter waarschuwen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, bluspoeder of waterstraal. Grotere brand met waterstraal bestrijden of met schuim, dat tegen alcohol bestand is.

Firefighter Protection

Geen bijzondere maatregelen nodig.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Niet beschermd personen op afstand houden.

Environmental

Met veel water verdunnen.

Cleanup methods

Met vloeistofbindend materiaal opnemen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voor goede ventilatie/afzuiging op de werkplaatsen zorgen. Aërosolvorming vermijden.

Storage

Tanks ondoordringbaar gesloten houden.

Fire prevention

Geen bijzondere maatregelen noodzakelijk.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Geen aanvullende gegevens. Zie 7.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Vloeibaar
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Volgens de productbeschrijving
Colour
Volgens de productbeschrijving
Colour Intensity
---
Form
---
Odor
Karakteristiek
Odor Threshold
---
Ph
1,5
Melting Point
Niet bepaald.
Boiling Point
213°C
Flash Point
Niet bruikbaar.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Niet bepaald.
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Het product ontbrandt niet uit zichzelf.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Volledig mengbaar.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen afbraak bij gebruik volgens voorschrift.

Hazardous reactions

Geen gevaarlijke reacties bekend.

Avoid

Geen afbraak bij gebruik volgens voorschrift.

Decomposition

Geen gevaarlijke ontbindingsprodukten bekend.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1805
Shipping Name
FOSFORZUUR, OPLOSSING
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Thermbond Formula Activator?

The signal word is danger.

What is the physical form of Thermbond Formula Activator?

Thermbond Formula Activator is a vloeibaar appearing as volgens de productbeschrijving with volgens de productbeschrijving color. It has karakteristiek odor.

What is Thermbond Formula Activator used for?

Activator

What are the hazard statements for Thermbond Formula Activator?

This substance has 1 hazard statement:

  • H314: Veroorzaakt ernstige brandwonden en oogletsel.

What is the melting point of Thermbond Formula Activator?

The melting point is Niet bepaald. and the boiling point is 213°C.