NextSDS Logo
Safety Data Sheet NL

Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR®

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR®
Product Code
170370
Chemical Name
ZrOCl₂ in HCl 7%

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagens voor analyse

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Germany

+49 6151 72-2440

Emergency Contacts

Merck KGaA

+49 6151 722440

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Waterige zoutzuuroplossing.

Chemical Name CAS Number Concentration Hazardous
Zoutzuur EC: 231-595-7 7647-01-0 1 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht.

Skin contact

Met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye contact

Geopende oogelden uitspoelen met ruim voldoende water. Oogarts raadplegen.

Ingestion

Onmiddellijk veel water drinken. Bij onwel bevinden arts raadplegen.

Immediate Medical Attention

Oogarts raadplegen bij oogcontact. Bij onwel bevinden na inslikken arts raadplegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Op de omgeving afstemmen.

Specific hazards

Niet brandbaar. Door brand in de omgeving is het ontstaan van gevaarlijke dampen mogelijk. In geval van brand mogelijk ontstaan van: chloorwaterstof.

Firefighter Protection

Blijf niet in de gevaarlijke zone zonder beademingsapparatuur die onafhankelijk is van de omgevingslucht. Om huidcontact te vermeiden, houd een veilige afstand en draag geschikte beschermende kleding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet in riolering laten geraken.

Cleanup methods

Met vloeistofabsorberend en neutraliserend matriaal, b.v. Chemizorb® H⁺ (Art.Nr. 101595) opnemen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen nadere eisen.

Storage

Goed afgesloten. Bij +15°C tot +25°C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
---
Ph
~ 0.5
Solubility In Fat
---
Properties Status
---
Solubility
---
Metal Corrosion
---
Physical State
vloeibaar
Relative Evaporation Rate
---
Molecular Weight
---
Form
---
Melting Point
niet beschikbaar
Solidification Point
---
Kinematic Viscosity
---
Colour Intensity
---
Flammability
---
Freezing Point
---
Physical State Data
liquid
Odor Threshold
---
Softening Point
---
Relative Density
---
Dynamic Viscosity
---
Flash Point
niet beschikbaar
Partition Coefficient
---
Crystallisation Point
---
Odor
geurloos
Explosive Limits
---
Vapor Pressure
---
Vapor Density
---
Lower Explosive Limit
niet beschikbaar
Appearance
vloeibaar, kleurloos, geurloos
Bulk Density
---
Solubility In Water
niet beschikbaar
Voc Content
---
Auto Ignition Temperature
niet beschikbaar
State Under Standard Conditions
---
Evaporation Rate
---
Density
~ 1.034 g/cm³
Upper Explosive Limit
niet beschikbaar
Boiling Point
niet beschikbaar
Colour
kleurloos
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Genereert gevaarlijke gassen of dampen bij contact met: metalen (vorming van waterstof).

Avoid

Verhitting.

Incompatible

metalen, metaallegeringen.

Decomposition

bij brand: Zie hoofdstuk 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Voor HCl geldt in het algemeen het volgende: Schadelijk effect voor waterorganismen. Schadelijke werking door pH-verschuiving. Biologische effecten: zoutzuur (en door reactie ontstane zoutzuur): dodelijk vanaf 25 mg/l voor vissen; Leuciscus idus LC₅₀: 862 mg/l (1N oplossing). Schadelijke effecten treden op: planten 6 mg/l.

12.2 Persistence and degradability

Veroorzaakt geen biologisch zuurstof tekort.

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Chemicaliën moeten met inachtneming van de desbetreffende nationale voorschriften afgevoerd worden.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1789
Shipping Name
HYDROCHLORIC ACID
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Etikettering volgens EG richtlijnen

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR®?

The signal word is no signal word.

What is the physical form of Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR®?

Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR® is a vloeibaar appearing as vloeibaar, kleurloos, geurloos with kleurloos color. It has geurloos odor.

What is Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR® used for?

Reagens voor analyse

What is the melting point of Zirconium ICP standaard herleidbaar naar SRM van NIST ZrOCl₂ in HCl 7% 1000 mg/l Zr CertiPUR®?

The melting point is niet beschikbaar and the boiling point is niet beschikbaar.