NextSDS Logo
Safety Data Sheet NL

Ammoniumnitraat pro analyse ACS

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ammoniumnitraat pro analyse ACS
Product Code
101188
Chemical Name
Ammoniumnitraat

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagens voor analyse, Chemische productie

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

64271 Darmstadt, Duitsland

+49 6151 72-2440

Emergency Contacts

Merck KGaA

+49 6151 722440

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

EUH006 Bevordert de ontbranding van brandbare stoffen.
H242 Ontploffingsgevaar bij menging met brandbare stoffen.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Synoniemen Ammonsalpeter, Ammoniumnitraat

Chemical Name CAS Number Concentration Hazardous
Ammonsalpeter, Ammoniumnitraat EC: 229-347-8 6484-52-2 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

frisse lucht.

Skin contact

met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye contact

uitspoelen met ruim voldoende water met de oogleden wijd open gehouden.

Ingestion

slachtoffer veel water laten drinken.

Immediate Medical Attention

Bij onwel bevinden arts raadplegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, CO₂, schuim, poeder.

Specific hazards

Brandbevorderend. Verwijderd houden van brandbare stoffen. In geval van brand kunnen er gevaarlijke brandgassen en dampen ontstaan.

Firefighter Protection

Niet in de gevaarlijke zone verblijven zonder onafhankelijke ademhalingsapparatuur.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Niet in riolering laten geraken.

Cleanup methods

Droog opnemen. Ter verwerking aanbieden. Vervuild gebied schoonmaken.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geen nadere eisen.

Storage

Goed afgesloten. Verwijderd van brandbare materialen en ontstekingsbronnen en hitte. TRGS 511 beachten. Droog. Opslagtemperatuur: zonder beperking

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Bij vol contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. Bij sproei contact: Handschoen materiaal: Nitrilrubber, Dikte van de laag: 0.11 mm, Doorbraaktijd: > 480 Min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 741 Dermatril® L (volledig contact), 741 Dermatril® L (spat contact).

Eyes

benodigd

Respiratory

nodig indien stofvorming plaatsvindt. Filter P 2 (volgens DIN 3181) voor vaste en vloeibare deeltjes van schadelijke stoffen.

Skin/Body

Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. De chemische weerstand van de bescherming moet met de leverancier geregeld worden.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
vast
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
kleurloos
Colour Intensity
---
Form
---
Odor
geurloos
Odor Threshold
---
Ph
4.5-7.0 (bij 100 g/l H₂O, 20 °C)
Melting Point
169 °C
Boiling Point
210 °C (valt uiteen)
Flash Point
niet van toepassing
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
niet van toepassing
Vapor Density
---
Relative Density
---
Bulk Density
~ 600-700 kg/m³
Density
1.72 g/cm³ (20 °C)
Flammability
---
Upper Explosive Limit
bovengrens: niet beschikbaar
Lower Explosive Limit
ondergrens: niet beschikbaar
Explosive Limits
---
Auto Ignition Temperature
niet van toepassing
Decomposition Temperature
> 180 °C
Solubility
---
Partition Coefficient
---
Solubility In Water
1920 g/l (20 °C)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

brand-bevorderende stof, hygroscopisch, lichtgevoelig

Hazardous reactions

Gevaar voor ontploffing met: / Exotherme reactie met: staal en metalen in poedervorm, alkalimetalen, niet-metalen, carbiden, brandbare stoffen, nitrieten, logen, zuren, ammoniumverbindingen, oxiderend middel, organische stoffen, aluminium in poedervorm, organische stikstofverbindingen, Sulfiden, zouten van gehalogeneerde zuurstofzuren, chloraten, Metaalchloriden, oliën, reducerend middel. Kans op ontbranding of vorming van brandbare gassen of dampen met: azijnzuur / hitte, metalen-nitrieten, ammoniumverbindingen, K₂Cr₂O₇.

Avoid

Sterke verhitting.

Incompatible

staal en metalen in poedervorm, alkalimetalen, niet-metalen, carbiden, brandbare stoffen, nitrieten, logen, zuren, ammoniumverbindingen, oxiderend middel, organische stoffen, aluminium in poedervorm, organische stikstofverbindingen, Sulfiden, zouten van gehalogeneerde zuurstofzuren, chloraten, Metaalchloriden, oliën, reducerend middel, azijnzuur, metalen-nitrieten, K₂Cr₂O₇, metalen, staal.

Decomposition

bij brand: Zie hoofdstuk 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1942
Shipping Name
AMMONIUM NITRATE
Transport Class
5.1
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ammoniumnitraat pro analyse ACS?

The signal word is danger.

What is the physical form of Ammoniumnitraat pro analyse ACS?

Ammoniumnitraat pro analyse ACS is a vast with kleurloos color. It has geurloos odor.

What is Ammoniumnitraat pro analyse ACS used for?

Reagens voor analyse, Chemische productie

What are the hazard statements for Ammoniumnitraat pro analyse ACS?

This substance has 2 hazard statements:

  • EUH006: Bevordert de ontbranding van brandbare stoffen.
  • H242: Ontploffingsgevaar bij menging met brandbare stoffen.

What is the melting point of Ammoniumnitraat pro analyse ACS?

The melting point is 169 °C and the boiling point is 210 °C (valt uiteen).