NextSDS Logo
Safety Data Sheet NL

CIP Speciaal

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CIP Speciaal
Product Code
1225500

Regulatory Identifiers

CAS Number
N/A

Identified Uses

industrieel reinigingsmiddel

Manufacturers & Suppliers

R

Relavit B.V.

manufacturer

Kilkade 2-6, 3316 BC Dordrecht

078-6550550

Emergency Contacts

Relavit B.V.

078-6550550

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

bijtend

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H314 veroorzaakt ernstige brandwonden

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Ingrediëntendeklaratie vlg. EEG-aanbeveling 89/542/EEG: niet ionogene oppervlakteactieve stoffen <5%, fosfaten <5%, kaliumhydroxide, silicaat, gluconaat

Chemical Name CAS Number Concentration Hazardous
Kaliumhydroxide EC: 215-181-3 1310-58-3 15 - 30% Yes
Natriumsilicaat EC: 215-687-4 1344-09-8 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

in de frisse lucht brengen

Skin contact

onmiddellijk met veel water afwassen, verontreinigde kleding onmiddellijk uittrekken.

Eye contact

ogen met open ooglid een aantal minuten onder stromend water afspoelen

Ingestion

mond spoelen en veel water drinken; geen braken opwekken

Immediate Medical Attention

Na oogcontact: een arts raadplegen. Na inslikken: onmiddellijk een arts waarschuwen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Het product zelf brandt niet; alle blusmiddelen zijn toegestaan.

Firefighter Protection

draag beschermende kleding, handschoenen en een oogbescherming

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

doordringen in riolering en grondwater voorkomen

Cleanup methods

met vloeistofbindend materiaal (zand, zaagmeel e.d.) opnemen

Materials: vloeistofbindend materiaal (zand, zaagmeel e.d.)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

draag geschikte beschermende kleding, handschoenen en oogbescherming. verontreinigde kleding onmiddellijk uittrekken

Storage

volgens richtlijnen voor gevaarlijke stoffen

Fire prevention

geen speciale maatregelen nodig

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

geen

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
vloeibaar
Colour
praktisch kleurloos
Auto Ignition Temperature
niet van toepassing
Bulk Density
---
Vapor Density
---
Colour Intensity
---
Softening Point
---
Partition Coefficient
---
Solubility In Water
volledig mengbaar
Molecular Weight
---
Flash Point
geen
Decomposition Temperature
---
Kinematic Viscosity
---
Solubility In Fat
---
Solubility
---
Voc Content
---
Freezing Point
---
Vapor Pressure
---
Cloud Point
---
Properties Status
---
State Under Standard Conditions
---
Lower Explosive Limit
---
Odor Threshold
---
Form
vloeibaar
Physical State Data
liquid
Appearance
---
Flammability
---
Boiling Point
100 °C.
Evaporation Rate
---
Dynamic Viscosity
6 mPas
Metal Corrosion
---
Relative Density
---
Melting Point
---
Density
1,3 g/cm³
Ph
13,9
Crystallisation Point
---
Relative Evaporation Rate
---
Explosive Limits
---
Solidification Point
---
Odor
praktisch reukloos
Upper Explosive Limit
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

geen afbraak bij gebruik volgens voorschrift

Hazardous reactions

bij contact met zuren komt warmte vrij

Incompatible

zuren

Decomposition

geen

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1814
Shipping Name
kaliumhydroxide, oplossing
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CIP Speciaal?

The signal word is danger.

What is the physical form of CIP Speciaal?

CIP Speciaal is a vloeibaar with praktisch kleurloos color. It has praktisch reukloos odor.

What is CIP Speciaal used for?

industrieel reinigingsmiddel

What are the hazard statements for CIP Speciaal?

This substance has 1 hazard statement:

  • H314: veroorzaakt ernstige brandwonden