Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Fluoride Standard for IC
- Product Code
- 77365
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- Dit product is een mengsel. REACH registratienummer zie hoofdstuk 3.
Identified Uses
Laboratoriumchemikaliën, Vervaardiging van stoffen
Manufacturers & Suppliers
Sigma-Aldrich
distributor
Merck Life Science BV
distributor
Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
Geen gevaarlijke ingrediënten
First Aid Measures
Emergency procedures for chemical exposure incidents
Na inhalatie: frisse lucht.
Eerstehulpbehandeling met calciumgluconaatpasta. Verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/afdouchen.
Na oog contact: uitspoelen met ruim voldoende water. Contactlenzen uitnemen.
Na inslikken: slachtoffer water laten drinken (niet meer dan twee glazen). Indien onwel: arts raadplegen. Absorptie van fluorionen in geval van opname door de mond kan worden voorkomen door melk, calciumcarbonaattabletten om op te kauwen of magnesiumoxide toe te dienen aan slachtoffers die bij bewustzijn zijn.
Immediate Medical Attention
Brandwonden veroorzaakt door fluorwaterstofzuur (HF) vereisen onmiddellijke en specialistische eerste hulp en medische behandeling.
Medical Treatment
De behandeling moet zowel gericht zijn op het binden van de fluorionen als op de effecten van de blootstelling. Bij ernstiger blootstelling van de huid kan onderhuidse toediening van calciumgluconaat nodig zijn, behalve rond vingers, tenzij de arts ervaring met deze techniek heeft, anders kan weefselletsel optreden door verhoogde druk.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Gebruik blusmiddelen die geschikt zijn voor de plaatselijke omstandigheden en de omgeving.
Voor deze stof / dit mengsel gelden geen beperkingen voor blusmiddelen.
Niet brandbaar. Door brand in de omgeving is het ontstaan van gevaarlijke dampen mogelijk.
Firefighter Protection
Draag bij brand een autonoom ademhalingsapparaat.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dampen, aërosol niet inademen. Gevarenzone ontruimen, noodprocedures volgen, een deskundige raadplegen.
Geen speciale maatregelen vereist.
Neem de mogelijke materiaalbeperkingen in acht (zie de paragrafen 7 en 10). Met vloeistofabsorberend materiaal, b.v. Chemizorb®, opnemen. Reinig het getroffen oppervlak.
Materials: vloeistofabsorberend materiaal, b.v. Chemizorb®
Related Products
Similar products with comparable safety profiles
Fluoride Standard - 100 ppm F
---
Activity standard solution for fluoride electrode (100 ppm as fluoride)
---
Custom Fluorine Standard: F @ 1000 µg/g in 75 cSt Mineral Oil
---
Bromate Standard for IC
---
SPADNS Reagent for Fluoride
UFI: 16TD-GE6Q-R004-PPHS
Propionate Standard for IC
---
Kaliumfluoride
CAS: 7789-23-3
Sodium fluoride
CAS: 7681-49-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Voor voorzorgsmaatregelen zie hoofdstuk 2.2
Goed afgesloten.
Verontreinigde kleding vervangen. Na het werken met de stof handen wassen.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
niet vereist
Gebruik gezichts- en/of oogbescherming getest en goedgekeurd door officiële instellingen zoals NIOSH (US) of EN166 (EU). beschermbril
Niet nodig; behalve bij aërosolvorming.
Geen speciale maatregelen vereist.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Het product is chemisch stabiel onder standaard omgevingsvoorwaarden (kamertemperatuur).
Geen gegevens beschikbaar
Heftige reacties mogelijk met: De algemeen bekende reactiepartners voor water.
geen informatie beschikbaar
Sterke oxidatiemiddelen
In geval van brand: zie hoofdstuk 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Fluoride Standard for IC?
The signal word is no signal word.
What is the physical form of Fluoride Standard for IC?
Fluoride Standard for IC is a vloeibaar with kleurloos color. It has geen gegevens beschikbaar odor.
What is Fluoride Standard for IC used for?
Laboratoriumchemikaliën, Vervaardiging van stoffen
What is the melting point of Fluoride Standard for IC?
The melting point is Geen gegevens beschikbaar and the boiling point is Geen gegevens beschikbaar.