01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ECO Floor 6

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Vloerreiniger voor professioneel gebruik

Manufacturers & Suppliers

Greenspeed logo

Greenspeed

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

+31703458737

http://www.greenspeed.eu/

Emergency Contacts

Emergency Contact

+32 70 245 245

Emergency Contact

+31 30 274 88 88

Emergency Contact

+ 33 (0)1 45 42 59 59

Emergency Contact

(+352) 8002-5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
C8-10 D-glucoside EC: 500-220-1 68515-73-1 5 - 15% Yes
Ethanol EC: 200-578-6 64-17-5 5% Yes
D-Glucopyranose, oligomeren, C10-16(even genummerd)-alkyl glycosiden EC: 600-975-8 110615-47-9 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bij ernstige of aanhoudende stoornissen: frisse lucht, rust en arts waarschuwen.

Symptoms: geen

Skin contact

Spoelen met water.

Symptoms: geen

Eye contact

Eerst spoelen met veel water, dan zonodig naar arts vervoeren.

Symptoms: roodheid

Ingestion

Eerst spoelen met veel water, dan zonodig naar arts vervoeren.

Symptoms: diarree, hoofdpijn, buikkrampen, slaperigheid, braken

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

verneveld water, poeder, schuim, CO2

Unsuitable media

geen

Specific hazards

geen

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Niet in de gemorste stoffen lopen of ze aanraken. Vermijden om de uitwasemingen, de rook, het stof en de damp in te ademen door boven de wind te blijven. Elk bezoedeld kledingstuk en elke bezoedelde beschermingsuitrusting na gebruik uittrekken en er zich op een veilige manier van ontdoen.

Environmental

Niet in riolering of openbare wateren laten wegstromen.

Cleanup methods

Gemorst product zorgvuldig verzamelen en opslaan in geschikte houders. Eventueel laten opzuigen door absorberend materiaal.

Materials: absorberend materiaal

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voorzichtig behandelen om lekkages te vermijden.

Storage

Bewaren in goed gesloten verpakking in een gesloten, vorstvrije, geventileerde ruimte.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Zorg voor een goede ventilatie van de werkplek.

Hands

Bij herhaald of langdurig contact met het onverdund product handschoenen dragen

Eyes

Bij het risico op het spatten van de vloeistof een veiligheidsbril dragen met zijbescherming.

Skin/Body

Draag geschikte beschermende kleding.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
vloeibaar
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
kenmerkend
Odor Threshold
Technisch onmogelijk
Ph
6,2
Melting Point
0 °C
Boiling Point
78 °C — 100 °C
Flash Point
/
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
2,000
Vapor Pressure
5 850 Pa
Vapor Density
Technisch onmogelijk
Relative Density
1,0130 kg/l
Bulk Density
---
Density
---
Flammability
Technisch onmogelijk
Upper Explosive Limit
19,000 %
Lower Explosive Limit
3,000 %
Explosive Limits
---
Auto Ignition Temperature
370 °C
Decomposition Temperature
/
Solubility
---
Partition Coefficient
Technisch onmogelijk
Solubility In Water
volledig oplosbaar
Solubility In Fat
---
Molecular Weight
---
Voc Content
4,00 %
Metal Corrosion
---
Dynamic Viscosity
1 mPa.s
Kinematic Viscosity
1 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Reactivity

Stabiel onder normale omstandigheden.

Hazardous reactions

geen

Avoid

Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50°C

Incompatible

zuren, basen, oxidatiemiddelen, reductiemiddelen

Decomposition

Ontleedt niet bij normaal gebruik

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ECO Floor 6?

The signal word is no signal word.

What is the physical form of ECO Floor 6?

ECO Floor 6 is a vloeibaar . It has kenmerkend odor.

What is ECO Floor 6 used for?

Vloerreiniger voor professioneel gebruik

What is the melting point of ECO Floor 6?

The melting point is 0 °C and the boiling point is 78 °C — 100 °C.