NextSDS Logo
Safety Data Sheet NL

Gasketseal

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Gasketseal
Product Form
Mengsel

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Afdichtingsmiddelen

Uses advised against

Geen aanvullende informatie beschikbaar

Manufacturers & Suppliers

Soudal N.V. logo

Soudal N.V.

distributor

Everdongenlaan 18-20, 2300 Turnhout, Belgium

+32 14 42 42 31

http://www.Soudal.com

Emergency Contacts

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Militaire Reine Astrid

+32 70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
triacetoxyethylsilaan EC: 241-677-4 17689-77-9 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

Skin contact

De huid met overvloedig water wassen. Bij huidirritatie of uitslag: een arts raadplegen.

Eye contact

Onmiddellijk en overvloedig spoelen met water. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Bij aanhoudende oogirritatie: een arts raadplegen.

Ingestion

Mond met water spoelen. Bij onwel voelen een arts raadplegen.

Medical Treatment

Symptomatische behandeling.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Verneveld water. Droog poeder. Schuim. Koolstofdioxide.

Unsuitable media

Geen enkele bekend.

Firefighter Protection

Niet ingrijpen zonder geschikte veiligheidsmiddelen. Onafhankelijk werkend ademhalingsapparaat. Volledig beschermende kleding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Verontreinigde omgeving ventileren.

Environmental

Voorkom lozing in het milieu.

Cleanup methods

Absorbeer gemorste producten met zand of aarde. Het geabsorbeerde product in afsluitbare vaten scheppen. Na werkzaamheden kleding en materiaal reinigen.

Materials: zand of aarde

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Zorg voor een goede ventilatie van de werkplek. Draag een persoonlijke beschermingsuitrusting.

Storage

Koel bewaren. De vaten gesloten houden als ze niet worden gebruikt.

Hygiene

Niet eten, drinken of roken tijdens het gebruik van dit product. Na hantering van dit product altijd handen wassen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Zorg voor een goede ventilatie van de werkplek.

Hands

Beschermende handschoenen

Eyes

Veiligheidsbril

Respiratory

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body

Draag geschikte beschermende kleding

Environmental

Voorkom lozing in het milieu.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Vloeibaar
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Variabele.
Colour Intensity
---
Form
Pasta-achtig.
Odor
azijngeur.
Odor Threshold
Niet beschikbaar
Ph
Niet van toepassing
Melting Point
Niet van toepassing
Boiling Point
Niet beschikbaar
Flash Point
> 100 °C
Freezing Point
Niet beschikbaar
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Niet beschikbaar
Vapor Density
---
Relative Density
Niet beschikbaar
Bulk Density
---
Density
1,03 g/l
Flammability
Niet van toepassing
Upper Explosive Limit
Niet beschikbaar
Lower Explosive Limit
Niet beschikbaar
Explosive Limits
---
Auto Ignition Temperature
Niet beschikbaar
Decomposition Temperature
Niet beschikbaar
Solubility
niet oplosbaar in water.
Partition Coefficient
Niet beschikbaar
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
< 0,5 %
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Niet beschikbaar
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous reactions

Geen gevaarlijke reacties bekend onder normale gebruiksomstandigheden.

Avoid

Geen onder aanbevolen opslag- en hanteringscondities (zie lid 7).

Incompatible

Oxiderende stoffen.

Decomposition

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Gasketseal?

The signal word is no signal word.

What is the physical form of Gasketseal?

Gasketseal is a vloeibaar with variabele. color. It has azijngeur. odor.

What is the solubility of Gasketseal?

niet oplosbaar in water.

What is Gasketseal used for?

Afdichtingsmiddelen

What is the melting point of Gasketseal?

The melting point is Niet van toepassing and the boiling point is Niet beschikbaar.