NextSDS Logo
Safety Data Sheet NL

RADIAMULS MG 2549V

CAS 142-18-7
EC 205-526-6

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIAMULS MG 2549V
Product Form
Stof
Chemical Name
2,3-dihydroxypropyl laurate

Regulatory Identifiers

CAS Number
142-18-7 Check regulations →
EC Number
205-526-6 Check regulations →
REACH No.
01-2119978215-31

Identified Uses

General overview of industrial uses of glycerol fatty esters General overview of professional uses of glycerol fatty esters General overview of consumer uses of glycerol fatty esters General overview of manufacturing uses of glycerol fatty esters General overview of formulation uses of glycerol fatty esters

Uses advised against

Geen aanvullende informatie beschikbaar

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2, 9940 Ertvelde - Belgium

+32 9 341 10 11

http://www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

SGS ERS

+1 888 765 6554

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
2,3-dihydroxypropyl laurate EC: 205-526-6 142-18-7 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Breng het slachtoffer in de frisse lucht. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

Skin contact

Spoelen met water. Gebruik van zeep toegestaan. Slachtoffer naar arts brengen als irritatie aanhoudt.

Eye contact

Spoelen met water. Slachtoffer naar oogarts brengen als irritatie aanhoudt.

Ingestion

Mond spoelen met water. Antigifcentrum raadplegen (www.who.int/ipcs/poisons/centre/directory/en). Indien men zich onwel voelt: medische dienst/arts raadplegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF-schuim. BC-poeder. Koolzuur. Droog zand. Poeder. Blusmiddelen aanpassen aan omgeving.

Unsuitable media

(VOLLE straal) water niet effectief als blusmiddel.

Specific hazards

Brandgevaar : DIRECT BRANDGEVAAR: Moeilijk brandbaar. In fijn verdeelde toestand: verhoogde kans op brand. INDIRECT BRANDGEVAAR: Bij temperatuur boven vlampunt: verhoogde kans op brand/explosie.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Gevarenzone afbakenen. Stofwolkvorming voorkomen bv. door bevochtigen. Bij stofvorming: omwonenden deuren en ramen laten sluiten. Bij hitte: omwonenden deuren en ramen laten sluiten.

Environmental

Bodem- en waterverontreiniging voorkomen.

Cleanup methods

Morsstof/restant zorgvuldig verzamelen. Indien gesmolten: morsvloeistof laten stollen en opscheppen. Morsstof opscheppen in afsluitbare vaten of in kunststof zakken. Bevulde oppervlakken reinigen met een overmaat water en zeepoplossing.

Materials: afsluitbare vaten of in kunststof zakken

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Op een goed geventileerde plaats bewaren. Opslaan bij omgevingstemperatuur. Beschermen tegen directe zonnestralen. In orde met de wettelijke normen. Bewaren bij een temperatuur <18°C

Fire prevention

PRODUCT VERWIJDERD HOUDEN VAN: ontstekingsbronnen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handschoenen. BIEDEN GOEDE BESCHERMING: nitrilrubber

Eyes

Bij stofontwikkeling: beschermende bril.

Respiratory

Bij stofontwikkeling: stofmasker met filtertype P2.

Skin/Body

Beschermende kleding.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Vaste stof
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Vaste stof in diverse vormen.
Colour
Wit tot licht geel.
Colour Intensity
---
Form
---
Odor
Kenmerkende geur. Bijna reukloos.
Odor Threshold
Geen gegevens beschikbaar
Ph
5 – 8
Melting Point
ca. 54 °C
Boiling Point
> 250 °C
Flash Point
ca. 230 °C (ASTM D92)
Freezing Point
Geen gegevens beschikbaar
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Geen gegevens beschikbaar
Vapor Pressure
< 0,01 hPa (20°C)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 960,3 kg/m³ (20°C)
Flammability
---
Upper Explosive Limit
Geen gegevens beschikbaar
Lower Explosive Limit
Geen gegevens beschikbaar
Explosive Limits
---
Auto Ignition Temperature
> 300 °C
Decomposition Temperature
> Vlampunt
Solubility
Oplosbaar in oliën/vetten. oplosbaar in de meeste organische oplosmiddelen. Niet oplosbaar in water.
Partition Coefficient
> 5 (estimated)
Solubility In Water
Niet oplosbaar in water.
Solubility In Fat
Oplosbaar in oliën/vetten.
Molecular Weight
---
Voc Content
< 0,1 % (1999/13/EC; 2004/42/EC; 2010/75/EU)
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
ca. 14 mm²/s (100°C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Reactivity

Bij verbranding: vorming van (koolstofmonoxide/koolstofdioxide).

Hazardous reactions

Geen aanvullende informatie beschikbaar

Avoid

Geen aanvullende informatie beschikbaar.

Incompatible

Geen aanvullende informatie beschikbaar.

Decomposition

Geen aanvullende informatie beschikbaar.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxiciteit

Ecologie - algemeen : Literatuur vermeldt: niet gevaarlijk voor het milieu. Ecologie - lucht : Geen aanvullende informatie beschikbaar. Ecologie - water : Geen gegevens beschikbaar over bioaccumulatie Gevaar voor het aquatisch milieu, (acuut) op korte termijn : Niet ingedeeld Gevaar voor het aquatisch milieu, (chronisch) op lange termijn : Niet ingedeeld

Literatuur vermeldt: niet gevaarlijk voor het milieu. Het product is niet ingedeeld voor aquatische gevaren.

12.2. Persistentie en afbreekbaarheid

Geen aanvullende informatie beschikbaar

12.3. Bioaccumulatie

12.3. Bioaccumulatie

Verdelingscoëfficiënt n-octanol/water (Log Pow) | > 5 (estimated)
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Morsstof opscheppen in afsluitbare vaten, In poedervorm: niet met perslucht overpompen, Bevulde oppervlakten reinigen met zeepoplossing

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Specifieke veiligheids-, gezondheids- en milieuureglementen en -wetgeving voor de stof of het mengsel

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIAMULS MG 2549V?

The signal word is no signal word.

What is the physical form of RADIAMULS MG 2549V?

RADIAMULS MG 2549V is a vaste stof appearing as vaste stof in diverse vormen. with wit tot licht geel. color. It has kenmerkende geur. bijna reukloos. odor.

What is the solubility of RADIAMULS MG 2549V?

Oplosbaar in oliën/vetten. oplosbaar in de meeste organische oplosmiddelen. Niet oplosbaar in water.

What is RADIAMULS MG 2549V used for?

General overview of industrial uses of glycerol fatty esters General overview of professional uses of glycerol fatty esters General overview of consumer uses of glycerol fatty esters General overview of manufacturing uses of glycerol fatty esters General overview of formulation uses of glycerol fatty esters

What is the melting point of RADIAMULS MG 2549V?

The melting point is ca. 54 °C and the boiling point is > 250 °C.