NextSDS Logo
Safety Data Sheet NL

Cera Grease H1 - 500ml

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Cera Grease H1 - 500ml
Product Code
210041

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Smeermiddel / Smeerstoffen

Manufacturers & Suppliers

P

PROMANTE sa

manufacturer

Gruuss-Strooss 53/A17, L-9991 Weiswampach

M

MCS België bv

distributor

Langerode 16, B-3460 Bekkevoort

+32 (0)16 47 37 00

E

Ex & Tric bv

distributor

Spoorwegstraat 1, B-8854 Sint-Denijs

+32 (0)56 20 69 50

P

Promanté LUX s.a.r.l.

distributor

11, route de Mondorf, L-5441 Remerschen

00352 / 26 38 37 31

Emergency Contacts

Antigifcentrum

(+32) 070 245 245

24h/d, 7d/wk

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
H336 Kan slaperigheid of duizeligheid veroorzaken.
H412 Schadelijk voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

P101 Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
P102 Buiten het bereik van kinderen houden.
P210 Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
P211 Niet in een open vuur of op andere ontstekingsbronnen spuiten.
P251 Ook na gebruik niet doorboren of verbranden.
P260 Stof/rook/gas/nevel/damp/spuitnevel niet inademen.
P410 + P412 Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
P501 De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Chemical Name CAS Number Concentration Hazardous
pentaan EC: 203-692-4 109-66-0 20 - 25% Yes
propaan EC: 200-827-9 74-98-6 12.5 - 20% Yes
isobutaan (bevattend ≥ 0,1% butadieen (203-450-8)) EC: 200-857-2 75-28-5 5 - 10% Yes
butaan (bevattend ≥ 0,1% butadieen (203-450-8)) EC: 203-448-7 106-97-8 5 - 10% Yes
1-decene, trimer, hydrogenated 157707-86-3 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht toedienen; bij klachten arts ontbieden.

Skin contact

Over het algemeen is het product niet prikkelend voor de huid

Eye contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen

Ingestion

Als de klachten niet minderen, een arts raadplegen

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Brandblusmaatregelen op omgeving afstemmen.

Specific hazards

Bij verhitting of brand ontstaan vergiftige gassen.

Firefighter Protection

Ademhalingstoestel aantrekken.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ademhalingstoestel aantrekken. Beschermende kleding aantrekken. Niet beschermde personen op afstand houden.

Environmental

Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Cleanup methods

Besmet materiaal zoals afval volgens punt 13 verwijderen.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

Storage

De overheidsbepalingen m.b.t. de opslag van drukgaspakkingen moeten in acht genomen worden. Tanks ondoordringbaar gesloten houden.

Fire prevention

Nietspuiten in de richting van een vlam of een gloeiend voorwerp. Onstekingsbronnen op afstand houden - niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Aërosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
---
Colour
Wit
Colour Intensity
---
Form
Aërosol
Odor
Oplosmiddelachtig
Odor Threshold
Niet bepaald.
Ph
Niet bepaald.
Melting Point
Niet bepaald.
Boiling Point
Vanwege aerosol niet bruikbaar.
Flash Point
Vanwege aerosol niet bruikbaar.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Niet bruikbaar.
Vapor Pressure
8.300 hPa (CAS: 74-98-6 propaan)
Vapor Density
Niet bepaald.
Relative Density
Niet bepaald.
Bulk Density
---
Density
Niet bepaald.
Flammability
---
Upper Explosive Limit
10,9 Vol % (CAS: 74-98-6 propaan)
Lower Explosive Limit
1,4 Vol % (CAS: 109-66-0 pentaan)
Explosive Limits
---
Auto Ignition Temperature
285 °C (Butene, homopolymer, CAS: 109-66-0 pentaan)
Decomposition Temperature
Niet bepaald.
Solubility
---
Partition Coefficient
Niet bepaald.
Solubility In Water
Niet resp. gering mengbaar.
Solubility In Fat
---
Molecular Weight
---
Voc Content
392,7 g/l
Metal Corrosion
---
Dynamic Viscosity
Niet bepaald.
Kinematic Viscosity
Niet bepaald.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen afbraak bij gebruik volgens voorschrift.

Reactivity

Geen verdere relevante informatie verkrijgbaar.

Hazardous reactions

Geen gevaarlijke reacties bekend.

Avoid

Geen verdere relevante informatie verkrijgbaar.

Incompatible

Geen verdere relevante informatie verkrijgbaar.

Decomposition

Geen gevaarlijke ontbindingsproducten bekend.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Aquatische toxiciteit

CAS: 109-66-0 pentaan LC50 / 96h 4,26 mg/l (fis) EC50 / 48h 9,7 mg/l (daphnia) EC50 / 96h 4,26 mg/l (fis)

12.1 Toxicity

Schadelijk voor vissen.

Het product is schadelijk voor vissen.

12.7 Other adverse effects

Andere schadelijke effecten. Gevaar voor water klasse 3 (D) (Zelfclassificatie): gevaar voor water groot. Niet lozen in grondwater, oppervlaktewater of riolering, ook niet in kleine hoeveelheden. Gevaar voor drinkwater zelfs bij het uitlopen van zeer geringe hoeveelheden in de ondergrond, schadelijk voor in het water levende organismen.

Het product is ingedeeld als gevaar voor water klasse 3 (groot gevaar). Het mag niet in het milieu worden geloosd en vormt een gevaar voor drinkwater en in het water levende organismen.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen.

Disposal

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen.

Waste Codes

HP3 Ontvlambaar EWC
HP5 Specifieke doelorgaantoxiciteit (STOT)/Aspiratietoxiciteit EWC
HP7 Kankerverwekkend EWC
HP11 Mutageen EWC
HP14 Ecotoxisch EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
SPUITBUSSEN / AEROSOLS
Transport Class
2.1
Packing Group
Niet van toepassing
ADR

Waarschuwing: Gassen

IMDG

SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow "separated from" class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Cera Grease H1 - 500ml?

The signal word is danger.

What is the physical form of Cera Grease H1 - 500ml?

Cera Grease H1 - 500ml is a aërosol with wit color. It has oplosmiddelachtig odor.

What is Cera Grease H1 - 500ml used for?

Smeermiddel / Smeerstoffen

What are the hazard statements for Cera Grease H1 - 500ml?

This substance has 3 hazard statements:

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H412: Schadelijk voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of Cera Grease H1 - 500ml?

The melting point is Niet bepaald. and the boiling point is Vanwege aerosol niet bruikbaar..