NextSDS Logo
Safety Data Sheet NL

Green Fix

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Green Fix

Regulatory Identifiers

CAS Number
N/A
REACH No.
Niet van toepassing (mengsel)

Identified Uses

Lijm/kleefstof

Uses advised against

Geen ontraden gebruiken gekend

Manufacturers & Suppliers

S

SOUDAL N.V.

distributor

Everdongenlaan 18-20, B-2300 Turnhout

+32 14 42 42 31

S

SOUDAL N.V.

manufacturer

Everdongenlaan 18-20, B-2300 Turnhout

+32 14 42 42 31

Emergency Contacts

BIG

+32 14 58 45 45

24u/24u

EN, FR, DE, NL

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
trimethoxyvinylsilaan EC: 220-449-8 2768-02-7 1 - 3% Yes
3-(trimethoxysilyl)propylamine EC: 237-511-5 13822-56-5 1 - 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Breng het slachtoffer in de frisse lucht. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

Symptoms: Geen effecten bekend.

Skin contact

Spoelen met water. Slachtoffer naar arts brengen als irritatie aanhoudt.

Symptoms: Geen effecten bekend.

Eye contact

Spoelen met water. Slachtoffer naar oogarts brengen als irritatie aanhoudt.

Symptoms: Geen effecten bekend.

Ingestion

Mond spoelen met water. Indien men zich onwel voelt: medische dienst/arts raadplegen.

Symptoms: Geen effecten bekend.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Werken in open lucht/onder plaatselijke afzuiging/met ventilatie of met ademhalingsbescherming.

Hands

Handschoenen.

Eyes

Geen oogbescherming vereist bij normaal gebruik.

Respiratory

Geen adembescherming vereist bij normaal gebruik.

Skin/Body

Beschermkleding.

Environmental

Zie rubrieken 6.2, 6.3 en 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Geen gegevens beschikbaar
Physical State Data
---
Ph
E Geen gegevens beschikbaar
Freezing Point
---
Crystallisation Point
---
Solubility
water ; niet oplosbaar
Lower Explosive Limit
---
Softening Point
---
Vapor Pressure
Geen gegevens beschikbaar
Solubility In Fat
---
Colour Intensity
---
Explosive Limits
---
Voc Content
---
Cloud Point
---
State Under Standard Conditions
---
Bulk Density
---
Kinematic Viscosity
Geen gegevens beschikbaar
Dynamic Viscosity
Geen gegevens beschikbaar
Properties Status
---
Relative Density
1.396 ; 20 ℃
Decomposition Temperature
Geen gegevens beschikbaar
Flammability
Niet ontvlambaar
Form
---
Evaporation Rate
Geen gegevens beschikbaar
Boiling Point
Geen gegevens beschikbaar
Upper Explosive Limit
---
Melting Point
Geen gegevens beschikbaar
Solubility In Water
niet oplosbaar
Solidification Point
---
Flash Point
Geen gegevens beschikbaar
Vapor Density
---
Density
1396 kg/m3 ; 20 ℃
Metal Corrosion
---
Physical State
---
Appearance
Pasta
Colour
Kleurvariabel, afhankelijk van de samenstelling
Relative Evaporation Rate
---
Partition Coefficient
Niet van toepassing (mengsel)
Molecular Weight
---
Odor
Kenmerkende geur
Auto Ignition Temperature
Geen gegevens beschikbaar
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Green Fix?

The signal word is no signal word.

What is the solubility of Green Fix?

water ; niet oplosbaar

What is Green Fix used for?

Lijm/kleefstof

What is the melting point of Green Fix?

The melting point is Geen gegevens beschikbaar and the boiling point is Geen gegevens beschikbaar.