NextSDS Logo
Chemical Substance

Extract residues (coal), benzole fraction alk., acid ext. Light Oil Extract Residues, low boiling [The redistillate from the distillate, freed of tar acids and tar bases, from bituminous coal high temperature tar boiling in the approximate range of 90°C to 160°C (194°F to 320°F). It consists predominantly of benzene, toluene and xylenes.] The redistillate from the distillate, freed of tar acids and tar bases, from bituminous coal high temperature tar boiling in the approximate range of 90°C to 160°C (194°F to 320°F). It consists predominantly of benzene, toluene and xylenes. 648-014-00-1

CAS Number91995-61-8
EC Number295-323-9
Screen your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now

Identifiers

Cas Number91995-61-8Primary
Ec Number295-323-9
Chemical NameExtract residues (coal), benzole fraction alk., acid ext. Light Oil Extract Residues, low boiling [The redistillate from the distillate, freed of tar acids and tar bases, from bituminous coal high temperature tar boiling in the approximate range of 90°C to 160°C (194°F to 320°F). It consists predominantly of benzene, toluene and xylenes.] The redistillate from the distillate, freed of tar acids and tar bases, from bituminous coal high temperature tar boiling in the approximate range of 90°C to 160°C (194°F to 320°F). It consists predominantly of benzene, toluene and xylenes. 648-014-00-1

GHS Hazard Pictograms

GHS08 Hazard PictogramGHS08

Hazard Classifications

Muta. 1B
Germ cell mutagenicity
Danger
Hazard CodeH340
CategoryMuta. 1B
Source: Harmonised C&L
Carc. 1B
Carcinogenicity
Danger
Hazard CodeH350
CategoryCarc. 1B
Source: Harmonised C&L

Regulatory Lists (4)

RIVM ZZS (ZEER ZORGWEKKENDE STOFFEN)
RIVM ZZS (Zeer Zorgwekkende Stoffen) — Dutch list of Substances of Very High Concern maintained by the National Institute for Public Health and the Environment (RIVM), based on REACH SVHC criteria and CMR/PBT/ED properties
KEMI PRIO PHASE-OUT SUBSTANCES
KEMI PRIO Phase-Out Substances — Swedish Chemicals Agency list of substances with properties of very high concern that should be phased out
EU CMR DIRECTIVE
EU CMR Directive — Substances classified as Carcinogenic, Mutagenic or Reprotoxic (CMR Cat. 1A/1B) restricted under Directive 2004/37/EC on carcinogens and mutagens at work
EU COSMETIC PRODUCTS REGULATION: PROHIBITED SUBSTANCES
EU Cosmetic Products Regulation: Prohibited Substances — Substances prohibited in cosmetic products under Annex II of Regulation (EC) No 1223/2009

Manage Your Chemicals

Track substances, monitor regulatory changes, and stay compliant.

Try NextSDS Free

Related Substances

Extract residues (coal tar), benzole fraction alk., acid ext. Light Oil Extract Residues, low boiling [A complex combination of hydrocarbons obtained by the redistillation of the distillate of high temperature coal tar (tar acid and tar base free). It consists predominantly of unsubstituted and substituted mononuclear aromatic hydrocarbons boiling in the range of 85°C to 195°C (185°F to 383°F).] A complex combination of hydrocarbons obtained by the redistillation of the distillate of high temperature coal tar (tar acid and tar base free). It consists predominantly of unsubstituted and substituted mononuclear aromatic hydrocarbons boiling in the range of 85°C-195°C (185°F-383°F). 648-015-00-7
101316-63-6
Distillates (coal tar), benzole fraction, BTX-rich Light Oil Redistillate, low boiling [A residue from the distillation of crude benzole to remove benzole fronts. Composed primarily of benzene, toluene and xylenes boiling in the range of approximately 75°C to 200°C (167°F to 392°F).] A residue from the distillation of crude benzole to remove benzole fronts. Composed primarily of benzene, toluene and xylenes boiling in the range of approximately 75°C to 200°C (167°F to 392°F). 648-004-00-7
101896-26-8
Extract oils (coal), acidic, tar-base free Methylnaphthalene Oil Extract Residue [The extract oil boiling in the range of approximately 220°C to 265°C (428°F to 509°F) from coal tar alkaline extract residue produced by an acidic wash such as aqueous sulfuric acid after distillation to remove tar bases. Composed primarily of alkylnaphthalenes.] The extract oil boiling in the range of approximately 220°C to 265°C (428°F to 509°F) from coal tar alkaline extract residue produced by an acidic wash such as aqueous sulfuric acid after distillation to remove tar bases. Composed primarily of alkylnaphthalenes. 648-096-00-9
84989-12-8
Extract residues (coal), light oil alk., distn. overheads Light Oil Extract Residues, low boiling [The first fraction from the distillation of aromatic hydrocarbons, coumarone, naphthalene and indene rich prefractionator bottoms or washed carbolic oil boiling substantially below 145°C (293°F). Composed primarily of C 7 and C 8 aliphatic and aromatic hydrocarbons.] The first fraction from the distillation of aromatic hydrocarbons, coumarone, naphthalene and indene rich prefractionator bottoms or washed carbolic oil boiling substantially below 145°C (293°F). Composed primarily of C7 and C8 aliphatic and aromatic hydrocarbons. 648-017-00-8
90641-02-4
Extract oils (coal), coal tar residual pyrolysis oils, naphthalene oil, distn. residues Redistillates [Residue from the distillation of dephenolated and debased methylnaphthalene oil (from bituminous coal tar and pyrolysis residual oils) with a boiling range of 240°C to 260°C (464°F to 500°F). Composed primarily of substituted dinuclear aromatic and heterocyclic hydrocarbons.] Residue from the distillation of dephenolated and debased methylnaphthalene oil (from bituminous coal tar and pyrolysis residual oils) with a boiling range of 240°C to 260°C (464°F to 500°F). Composed primarily of substituted dinuclear aromatic and heterocyclic hydrocarbons. 648-040-00-3
122070-80-8

Disclaimer

The substance data provided is sourced from various third-party databases and regulatory sources. While we strive to maintain accuracy, we cannot guarantee the completeness, accuracy, or timeliness of this information. Users are responsible for verifying all data before use in compliance, safety, or regulatory contexts. NextSDS is not liable for any decisions made based on this data.