Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DOOSAN HYDRAULIC POWER VG46
- Product Code
- 76912
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Schmiermittel fr Hydrauliksysteme.
Uses advised against
Dieses Produkt sollte ohne den Rat eines Experten fr keine anderen Zwecke als den angegebenen verwendet werden.
Manufacturers & Suppliers
PETRONAS LUBRICANTS ITALY S.P.A.
Via Santena 1 10029 Villastellone (Torino)
+39.01196131
Emergency Contacts
Emergency Contact
+49 89 220 61012
24h/7d
Emergency Contact
0800 000 7801
24h/7d
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Stark raffinierte mineralische und/oder synthetische le, Additive.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 1.5 - 2% | Yes |
| N/A | --- | 0.1 - 0.25% | Yes |
| N/A | --- | 0.01% | Yes |
| N/A | --- | --- | Yes |
| N/A | --- | 90 - 100% | No |
Notes
Die in diesem Produkt enthaltenen mineralischen Grundle sind stark raffiniert und enthalten nach IP 346 einen DMSO-extrahierbaren Anteil von weniger als 3% und werden daher gem der Verordnung (EG) Nr. 1272/2008 nicht als karzinogen eingestuft, beachten sie die Anmerkung L. Die Einstufung als karzinogen ist nicht zwingend, wenn nachgewiesen werden kann, dass der Stoff weniger als 3 % DMSO-Extrakt, gemessen nach dem Verfahren IP 346 ("Bestimmung der polyzyklischen Aromate in nicht verwendeten Schmierlen und asphaltenfreien Erdlfraktionen Dimethylsulfoxid-Extraktion-BrechungsindexMethode", Institute of Petroleum, London), enthlt. Diese Anmerkung gilt nur fr bestimmte komplexe lderivate in Teil 3.
First Aid Measures
Emergency procedures for chemical exposure incidents
Fr Frischluft sorgen und wenn ntig Arzt aufsuchen.
Verunreinigte Kleidung und Schuhe entfernen und grndlich mit viel Wasser und Seife aussplen.
Augen bei geffnetem Lidspalt wenigstens 10 Minuten lang grndlich mit reichlich Wasser aussplen. Kontaktlinsen entfernen, falls dies leicht mglich ist. Im Falle von Kontakt mit erhitzten Produkten zum Abkhlen mit viel Wasser splen. Sofort Arzt aufsuchen, um Augen zu untersuchen und eine entsprechende Behandlung durchfhren zu lassen.
Symptoms: Bei Auftreten von Schmerzen und Rtungen
Kein Erbrechen auslsen, um ein Eintreten in die Atemwege zu vermeiden. Mund grndlich mit Wasser aussplen. Sofort Arzt aufsuchen
Immediate Medical Attention
Bei Auftreten von Schmerzen und Rtungen medizinische Versorgung in Anspruch nehmen. Sofort Arzt aufsuchen, um Augen zu untersuchen und eine entsprechende Behandlung durchfhren zu lassen. Sofort Arzt aufsuchen (nach Verschlucken). Wenn ntig Arzt aufsuchen (nach Einatmen).
Medical Treatment
Siehe Abschnitt 4.1. Sofort Arzt aufsuchen, um Augen zu untersuchen und eine entsprechende Behandlung durchfhren zu lassen. Sofort Arzt aufsuchen (nach Verschlucken). Wenn ntig Arzt aufsuchen (nach Einatmen).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Bildung und Verbreitung von Nebel und Aerosol unter Verwendung der rtlichen Lftung/Abzug oder anderen erforderlichen Vorkehrungen vermeiden. Alle erforderlichen Vorkehrungen zur Vermeidung der Produktverteilung in der Umgebung treffen (z. B. Strahlsyste
Geeignete Schutzhandschuhe tragen (z.B. aus Neopren, Nitril). Abgenutzte Handschuhe ersetzen. Handschuhe und Nutzung werden vom Arbeitgeber unter Bercksichtigung der Arbeitsablufe, der Regelungen zur persnlichen Schutzausrstung und den Angaben des Herstellers der Handschuhe vorgegeben. Handschuhe nur mit sauberen Hnden verwenden.
Chemische Schutzbrille und Gesichtsschutz bei lspritzern.
Nicht erforderlich unter normalen Bedingungen. Zugelassene Atemschutzmaske mit organischem Dampffilter verwenden, wenn die empfohlenen Expositionsgrenzwerte berschritten werden.
Geeignete Schutzkleidung tragen (fr nhere Angaben siehe DIN EN 14605), bei starker Verschmutzung sofort entfernen und vor erneutem Gebrauch waschen.
Siehe hierzu die Gebrauchsbedingungen und auch die Abschnitte 6.2, 6.3, 7.2, 12 und 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DOOSAN HYDRAULIC POWER VG46?
The signal word is no signal word.
What is the physical form of DOOSAN HYDRAULIC POWER VG46?
DOOSAN HYDRAULIC POWER VG46 is a flssig/flssigkeit appearing as viskos bernsteinfarben with bernsteinfarben color. It has nicht relevant odor.
What is DOOSAN HYDRAULIC POWER VG46 used for?
Schmiermittel fr Hydrauliksysteme.
What is the melting point of DOOSAN HYDRAULIC POWER VG46?
The melting point is N.A. and the boiling point is >250 C (482 F) ( ASTM D2887 ).