NextSDS Logo
Safety Data Sheet DE

Fruchtfliegenfalle Profi

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Fruchtfliegenfalle Profi

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Falle zur Befallsermittlung (Monitoring) von Fruchtfliegen (Drosophila melanogaster) in Wohnhäusern oder industriellen Gebäuden.

Manufacturers & Suppliers

K

Kwizda Agro GmbH

manufacturer

Universitätsring 6, A-1010 Wien

+43 (0) 59977 10

K

Kwizda Werk Leobendorf

manufacturer

+43 (0) 59977 40

Emergency Contacts

VergiftungsInformationsZentrale, Wien

+43 (0)1 406 43 43

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Wässrige Lösung mit Nahrungsmittelaromen und oberflächenaktiven Substanzen.

Notes

Gefährliche Inhaltsstoffe: entfällt

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frischluftzufuhr, bei Beschwerden Arzt aufsuchen.

Skin contact

Verunreinigte Kleidungsstücke entfernen. Mit viel Wasser und Seife gründlich abspülen. Bei auftretender Reizung Arzt aufsuchen.

Eye contact

Augen bei geöffnetem Lidspalt mehrere Minuten mit fließendem Wasser spülen.

Ingestion

Mund mit viel Wasser ausspülen. Bei anhaltendem Unwohlsein ärztlichen Rat einholen.

Medical Treatment

Behandlung symptomatisch.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Das Produkt selbst ist nicht brennbar. Löschmaßnahmen auf die Umgebung abstimmen.

Specific hazards

Keine weiteren relevanten Informationen verfügbar.

Firefighter Protection

Hinsichtlich des Produktes ist keine besondere Schutzausrüstung notwendig. Schutzausrüstung auf den jeweiligen Brandfall abstimmen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Berührung mit den Augen und der Haut vermeiden.

Environmental

Keine besonderen Maßnahmen erforderlich.

Cleanup methods

Kontaminierte Flächen und Gegenstände mit viel Wasser säubern.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Augen- und Hautkontakt mit dem Produkt vermeiden.

Storage

Den Behälter fest verschlossen halten. Für Kinder und Haustiere unzugänglich lagern.

Fire prevention

Keine besonderen Maßnahmen erforderlich.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Nicht erforderlich.

Eyes

Beim Umfüllen Schutzbrille empfehlenswert.

Respiratory

Nicht erforderlich.

Skin/Body

Nicht erforderlich.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Flüssig
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Flüssig
Colour
Rot
Colour Intensity
---
Form
Flüssig
Odor
Nach Essig
Odor Threshold
Keine Daten verfügbar
Ph
3,5
Melting Point
---
Boiling Point
> 100 °C
Flash Point
Das Produkt ist nicht entzündbar.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,03 kg/dm³
Flammability
Nicht relevant.
Upper Explosive Limit
Keine Daten verfügbar.
Lower Explosive Limit
Keine Daten verfügbar.
Explosive Limits
---
Auto Ignition Temperature
Das Produkt ist nicht selbstentzündlich.
Decomposition Temperature
Keine Daten verfügbar.
Solubility
---
Partition Coefficient
Keine Daten verfügbar
Solubility In Water
Mischbar
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Keine Daten verfügbar.
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabil unter angegebenen Lagerungsbedingungen.

Reactivity

Keine weiteren relevanten Informationen verfügbar.

Hazardous reactions

Keine gefährlichen Reaktionen bei bestimmungsgemäßer Verwendung bekannt.

Avoid

Extreme Temperaturen

Incompatible

Keine weiteren relevanten Informationen verfügbar.

Decomposition

Keine gefährlichen Zersetzungsprodukte bekannt.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Kleine Mengen können mit reichlich Wasser verdünnt und weggespült werden. Größere Mengen sind gemäß örtlicher behördlicher Vorschriften zu entsorgen.

Disposal

Kleine Mengen können mit reichlich Wasser verdünnt und weggespült werden. Größere Mengen sind gemäß örtlicher behördlicher Vorschriften zu entsorgen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Fruchtfliegenfalle Profi?

The signal word is no signal word.

What is the physical form of Fruchtfliegenfalle Profi?

Fruchtfliegenfalle Profi is a flüssig appearing as flüssig with rot color. It has nach essig odor.

What is Fruchtfliegenfalle Profi used for?

Falle zur Befallsermittlung (Monitoring) von Fruchtfliegen (Drosophila melanogaster) in Wohnhäusern oder industriellen Gebäuden.