NextSDS Logo
Safety Data Sheet DE

KEW – VM V

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
KEW – VM V

Regulatory Identifiers

CAS Number
N/A
REACH No.
nicht anwendbar

Identified Uses

Verbundmörtel

Uses advised against

keine

Manufacturers & Suppliers

KEW® Kunststofferzeugnisse GmbH Wilthen logo

KEW® Kunststofferzeugnisse GmbH Wilthen

manufacturer

Dresdener Straße 19, 02681 Wilthen / DEUTSCHLAND

+49 (0)3592 3853-0

www.kew-werke.de

Emergency Contacts

Emergency Contact

+49 (0)361-730730

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

STOT SE Cat. 3
Skin Sens. Cat. 1

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Ethylendimethacrylat EC: 202-617-2 97-90-5 10 - 25% Yes
Dibenzoylperoxid EC: 202-327-6 94-36-0 2.5% Yes
Methacrylsure, Monoester mit Propan-1,2-diol EC: 248-666-3 27813-02-1 2.5 - 10% Yes

Notes

Der Wortlaut der angefhrten R-Stze ist dem Kapitel 16 zu entnehmen.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Für Frischluft sorgen. Bei Beschwerden ärztlicher Behandlung zuführen.

Skin contact

Bei Berührung mit der Haut sofort mit viel Wasser und Seife abwaschen. Bei andauernder Hautreizung Arzt aufsuchen.

Eye contact

Bei Berührung mit den Augen gründlich mit viel Wasser spülen und Arzt konsultieren.

Ingestion

Sofort Arzt hinzuziehen. Kein Erbrechen einleiten.

Immediate Medical Attention

Sofort Arzt hinzuziehen.

Medical Treatment

Symptomatisch behandeln.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Fr ausreichende Be- und Entlftung am Arbeitsplatz sorgen.

Hands

Butylkautschuk, >120 min (EN 374).

Eyes

Schutzbrille.

Respiratory

Atemschutz bei hohen Konzentrationen. Kurzzeitig Filtergert, Kombinationsfilter A-P2.

Skin/Body

Leichte Schutzkleidung.

Environmental

nicht bestimmt

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour Intensity
---
Freezing Point
---
Physical State Data
---
Flammability
nicht bestimmt
Auto Ignition Temperature
nicht anwendbar
Kinematic Viscosity
---
Metal Corrosion
---
Solubility In Water
praktisch unlslich
Vapor Pressure
< 0,01 (20)
Odor Threshold
---
Lower Explosive Limit
nicht bestimmt
Colour
verschieden
Form
pasts
State Under Standard Conditions
---
Physical State
---
Relative Density
---
Softening Point
---
Solidification Point
---
Relative Evaporation Rate
---
Density
1,6-1,7 (20)
Odor
charakteristisch
Cloud Point
---
Appearance
---
Boiling Point
212
Flash Point
> 60
Properties Status
---
Voc Content
---
Bulk Density
nicht anwendbar
Decomposition Temperature
nicht bestimmt
Dynamic Viscosity
---
Explosive Limits
---
Molecular Weight
---
Vapor Density
---
Ph
nicht anwendbar
Solubility
---
Evaporation Rate
nicht bestimmt
Partition Coefficient
nicht bestimmt
Melting Point
nicht bestimmt
Crystallisation Point
---
Solubility In Fat
---
Upper Explosive Limit
nicht bestimmt
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for KEW – VM V?

The signal word is na: r-phrases.

What is KEW – VM V used for?

Verbundmörtel

What is the melting point of KEW – VM V?