NextSDS Logo
KE

KEW - VM V

NA: R-PHRASES SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
KEW - VM V

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

KEW - VM V .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

na: r-phrases

Hazard Classifications

STOT SE Category 3
Skin Sens. Category 1

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

KEW Kunststofferzeugnisse GmbH Wilthen company logo - Safety Data Sheet supplier organization

KEW Kunststofferzeugnisse GmbH Wilthen

manufacturer

πŸ“

Dresdener Strae 19 02681 Wilthen / DEUTSCHLAND

🌍

DE

πŸ“ž

+49 (0)3592 3853-0

πŸ“ 

+49 (0)3592 3853-51

🌐 www.kew-werke.de

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+49 (0)361-730730

🌍

DE

πŸ•’

24h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethylendimethacrylat
EC: 202-617-2
97-90-5 10-25% ⚠️ Hazardous
Dibenzoylperoxid
EC: 202-327-6
94-36-0 2.5% ⚠️ Hazardous
Methacrylsure, Monoester mit Propan-1,2-diol
EC: 248-666-3
27813-02-1 2.5-10% ⚠️ Hazardous

Composition Notes

Der Wortlaut der angefhrten R-Stze ist dem Kapitel 16 zu entnehmen.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

FΓΌr Frischluft sorgen. Bei Beschwerden Γ€rztlicher Behandlung zufΓΌhren.

πŸ–οΈ Skin Contact

Bei BerΓΌhrung mit der Haut sofort mit viel Wasser und Seife abwaschen. Bei andauernder Hautreizung Arzt aufsuchen.

πŸ‘οΈ Eye Contact

Bei BerΓΌhrung mit den Augen grΓΌndlich mit viel Wasser spΓΌlen und Arzt konsultieren.

🍽️ Ingestion/Swallowing

Sofort Arzt hinzuziehen. Kein Erbrechen einleiten.

🚨 Immediate Medical Attention Required

Sofort Arzt hinzuziehen.

Medical Treatment

Symptomatisch behandeln.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ’¨ Evaporation Rate
nicht bestimmt
πŸ“Š Odor Threshold
Not available
πŸ“Š Relative Density
Not available
πŸ“Š Auto Ignition Temperature
nicht anwendbar
πŸ“Š Decomposition Temperature
nicht bestimmt
🧊 Melting Point
nicht bestimmt
Critical Property
πŸ“Š Solidification Point
Not available
βš–οΈ Density
1,6-1,7 (20)
Critical Property
πŸ“Š Form
pasts
πŸ“Š Freezing Point
Not available
πŸ“Š Partition Coefficient
nicht bestimmt
πŸ“Š State Under Standard Conditions
Not available
πŸ‘ƒ Odor
charakteristisch
🎨 Colour
verschieden
πŸ“Š Voc Content
Not available
πŸ’¨ Boiling Point
212
Critical Property
πŸ“Š Vapor Density
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Lower Explosive Limit
nicht bestimmt
πŸ’¨ Vapor Pressure
< 0,01 (20)
πŸ’§ Solubility
Not available
πŸ“Š Solubility In Water
praktisch unlslich
πŸ”₯ Flash Point
> 60
Critical Property
πŸ“Š Colour Intensity
Not available
πŸ§ͺ Ph
nicht anwendbar
πŸ“Š Metal Corrosion
Not available
πŸ§ͺ Physical State
Not available
πŸ“Š Physical State Data
Not available
πŸ”₯ Flammability
nicht bestimmt
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Properties Status
Not available
πŸ“Š Upper Explosive Limit
nicht bestimmt
πŸ“Š Cloud Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Bulk Density
nicht anwendbar
πŸ“Š Solubility In Fat
Not available
πŸ‘οΈ Appearance
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Explosive Limits
Not available
πŸ“Š Kinematic Viscosity
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Fr ausreichende Be- und Entlftung am Arbeitsplatz sorgen.

🧀 Hand Protection

Butylkautschuk, >120 min (EN 374).

πŸ‘οΈ Eye Protection

Schutzbrille.

😷 Respiratory Protection

Atemschutz bei hohen Konzentrationen. Kurzzeitig Filtergert, Kombinationsfilter A-P2.

🦺 Skin/Body Protection

Leichte Schutzkleidung.

🌍 Environmental Exposure Controls

nicht bestimmt

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for KEW - VM V?

The signal word for this substance is "na: r-phrases".

What is the melting point of KEW - VM V?

The melting point is nicht bestimmt and the boiling point is 212.