NextSDS Logo
Safety Data Sheet DE

KEW – VM V

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
KEW – VM V

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Verbundmörtel

Manufacturers & Suppliers

KEW® Kunststofferzeugnisse GmbH Wilthen logo

KEW® Kunststofferzeugnisse GmbH Wilthen

manufacturer

Dresdener Straße 19, 02681 Wilthen / DEUTSCHLAND

+49 (0)3592 3853-0

http://www.kew-werke.de

Emergency Contacts

Emergency Contact

+49 (0)361-730730

24h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ethyldimethacrylat EC: 202-617-2 97-90-5 10 - 25% No
Dibenzoylperoxid EC: 202-327-6 94-36-0 2.5% No
Methacrylsäure, Monoester mit Propan-1,2-diol EC: 248-666-3 27813-02-1 2.5 - 10% No

Notes

Der Wortlaut der angeführten R-Sätze ist dem Kapitel 16 zu entnehmen.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Für Frischluft sorgen. Bei Beschwerden ärztlicher Behandlung zuführen.

Skin contact

Bei Berührung mit der Haut sofort mit viel Wasser und Seife abwaschen. Bei andauernder Hautreizung Arzt aufsuchen.

Eye contact

Bei Berührung mit den Augen gründlich mit viel Wasser spülen und Arzt konsultieren.

Ingestion

Sofort Arzt hinzuziehen. Kein Erbrechen einleiten.

Medical Treatment

Symptomatisch behandeln.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Schaum, Löschpulver, Wassersprühstrahl.

Unsuitable media

Wasservollstrahl.

Specific hazards

Gefahr der Bildung toxischer Pyrolyseprodukte.

Firefighter Protection

Umluftunabhängiges Atemschutzgerät verwenden.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Nicht in die Kanalisation/Oberflächenwasser/Grundwasser gelangen lassen.

Cleanup methods

Mechanisch aufnehmen.

Materials: flüssigkeitsbindendes Material (z.B. Sand)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Bei sachgemäßer Verwendung keine besonderen Maßnahmen erforderlich.

Storage

Behälter dicht geschlossen halten. Kühl lagern. Behälter an einem gut gelüfteten Ort aufbewahren. Empfohlene Lagertemperatur: 20 °C.

Fire prevention

Keine besonderen Maßnahmen erforderlich.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Für ausreichende Be- und Entlüftung am Arbeitsplatz sorgen.

Hands

Butylkautschuk, >120 min (EN 374).

Eyes

Schutzbrille.

Respiratory

Atemschutz bei hohen Konzentrationen. Kurzzeitig Filtergerät, Kombinationsfilter A-P2.

Skin/Body

Leichte Schutzkleidung.

Environmental

nicht bestimmt

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Kinematic Viscosity
---
Explosive Limits
---
Relative Density
---
Appearance
---
Boiling Point
212 °C
Vapor Pressure
< 0,01 kPa (20°C)
Colour
verschieden
Form
pastös
Crystallisation Point
---
Odor
charakteristisch
Solubility In Water
praktisch unlöslich
Partition Coefficient
nicht bestimmt
Vapor Density
---
Cloud Point
---
Physical State Data
liquid
Odor Threshold
---
Flammability
nicht bestimmt
Upper Explosive Limit
nicht bestimmt
Colour Intensity
---
Molecular Weight
---
Softening Point
---
Physical State
pastös
Voc Content
---
Freezing Point
---
Dynamic Viscosity
---
Metal Corrosion
---
Flash Point
> 60 °C
Decomposition Temperature
nicht bestimmt
Properties Status
---
Relative Evaporation Rate
---
Ph
nicht anwendbar
Density
1,6-1,7 g/ml (20°C)
Solubility In Fat
---
Lower Explosive Limit
nicht bestimmt
Auto Ignition Temperature
nicht anwendbar
Bulk Density
nicht anwendbar
Solubility
---
Solidification Point
---
Evaporation Rate
nicht bestimmt
State Under Standard Conditions
---
Melting Point
nicht bestimmt
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Reaktionen mit Reduktionsmitteln, Schwermetallen. Reaktionen mit starken Säuren und Alkalien.

Decomposition

Keine gefährlichen Zersetzungsprodukte bekannt.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Fischtoxizität: nicht anwendbar; Daphnientoxizität: nicht anwendbar; Bakterientoxizität: nicht anwendbar

Die Fisch-, Daphnien- und Bakterientoxizität sind nicht anwendbar.

12.2 Persistence and degradability

Biologische Abbaubarkeit: nicht anwendbar; CSB: nicht anwendbar; BSB 5: nicht anwendbar

Biologische Abbaubarkeit, CSB und BSB 5 sind nicht anwendbar.

12.3 Bioaccumulative potential

Verhalten in Umweltkompartimenten: nicht anwendbar

12.4 Mobility in soil

Verhalten in Umweltkompartimenten: nicht anwendbar

12.5 Results of PBT and vPvB assessment

Nicht angegeben.

12.6 Endocrine disrupting properties

Nicht angegeben.

12.7 Other adverse effects

AOX-Hinweis: nicht bestimmt; 2006/11/EG: nicht anwendbar; Allgemeine Hinweise: Keine Einstufung nach Berechnungsverfahren der Zubereitungsrichtlinie.

Keine Einstufung nach Berechnungsverfahren der Zubereitungsrichtlinie.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Unter Beachtung der örtlichen behördlichen Vorschriften einer Verbrennungsanlage zuführen. Als gefährlichen Abfall entsorgen.

Waste Codes

080409* Klebstoff- und Dichtungsmassenabfälle, die organische Lösemittel oder andere gefährliche Stoffe enthalten. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Das Produkt ist nach EG-Richtlinien eingestuft und gekennzeichnet.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for KEW – VM V?

The signal word is na: r-phrases.

What is the physical form of KEW – VM V?

KEW – VM V is a pastös with verschieden color. It has charakteristisch odor.

What is KEW – VM V used for?

Verbundmörtel

What is the melting point of KEW – VM V?

The melting point is nicht bestimmt and the boiling point is 212 °C.