NextSDS Logo
Safety Data Sheet DE

UNICUT-SAW-EP-HT (hochtemperaturfest) Hochl. Sägeschneidflüssigkeit

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UNICUT-SAW-EP-HT (hochtemperaturfest) Hochl. Sägeschneidflüssigkeit

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

U

UNICUT WAHL GmbH

manufacturer

Feld-Vorstmann Str. 14, D-56170 Bendorf

Emergency Contacts

Emergency Contact

02622/4266

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mischung aus pflanzlichen Fettsäureestern mit AW und EP Additiven und verdampfungsarmem Mineraloelerstraffinat

Kein gefhrlicher Arbeitsstoff n.d. Verordnung vom Nov. 93 ber gefhrliche Arbeitsstoffe und deren Zubereitungen und unterliegt nicht der Kennzeichnungspflicht.

Notes

Kein gefährlicher Arbeitsstoff n.d. Verordnung vom Nov. 93 über gefährliche Arbeitsstoffe und deren Zubereitungen und unterliegt nicht der Kennzeichnungspflicht.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

nicht zutreffend

Skin contact

Bei Berührung mit der Haut sofort abwaschen mit viel Wasser und Seife.

Eye contact

Bei Berührung mit den Augen gründlich mit Wasser abspülen.

Ingestion

Sofort ärztlichen Rat einholen.

Medical Treatment

Sicherheitsdatenblatt vorlegen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Schaum, Löschpulver, Kohlendioxid, Wassersprühstrahl

Specific hazards

Schwefeldioxid (S02)

Firefighter Protection

Unabhängiges Atemschutzgerät (Isoliergerät) verwenden.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Besondere Rutschgefahr durch ausgelaufenes/verschüttetes Produkt.

Environmental

Nicht in den Untergrund/Erdreich gelangen lassen. Nicht in die Kanalisation/Oberflächenwasser/Grundwasser.

Cleanup methods

Mit geeigneten flüssigkeitsbindenden Materialien aufnehmen.

Materials: geeignete flüssigkeitsbindende Materialien

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Bei sachgemäßer Verwendung keine besonderen Maßnahmen erforderlich.

Storage

Von +5°C bis +40°C lagern. Vor Frost und direkter Sonnenbestrahlung schützen. Unmittelbar vor Gebrauch möglichst bei Raumtemperatur lagern.

Fire prevention

Keine besonderen Maßnahmen erforderlich.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

entfällt

Hands

Handschuhe (ölbeständig)

Eyes

Schutzbrille (Beim Umfüllen)

Respiratory

nicht zutreffend

Skin/Body

Schürze aus Gummi

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour Intensity
---
Properties Status
---
Physical State
flüssig
Appearance
---
Flash Point
250 °C
Voc Content
---
Solidification Point
---
Solubility
---
Crystallisation Point
---
Evaporation Rate
---
Metal Corrosion
---
Partition Coefficient
---
Relative Density
---
Relative Evaporation Rate
---
Molecular Weight
---
Melting Point
---
Kinematic Viscosity
ca.312mm²/s
Upper Explosive Limit
---
Ph
n.b.
Odor
mild
State Under Standard Conditions
---
Boiling Point
---
Vapor Pressure
---
Vapor Density
---
Odor Threshold
---
Explosive Limits
---
Freezing Point
---
Solubility In Fat
---
Physical State Data
liquid
Density
ca. 970 kg/m³
Form
flüssig
Cloud Point
---
Lower Explosive Limit
---
Dynamic Viscosity
---
Solubility In Water
unlöslich
Decomposition Temperature
---
Colour
rot
Flammability
---
Auto Ignition Temperature
300 °C
Softening Point
---
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Keine Zersetzung bei bestimmungsgemäßer Verwendung.

Decomposition

Schwefeloxide (SOx), Schwefelwasserstoff (H2S) bei totaler Verbrennung

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Sonderabfallverbrennung

Disposal

Muß unter Beachtung der Sonderabfallvorschr. nach Vorbeh. einer zugelassenen Sonderabfallverbr. zugeführt werden.

Waste Codes

54109 Schneidoele national code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Das Produkt ist nach EG-Richtlinien/den jeweiligen nationalen Gesetzen nicht kennzeichnungspflichtig.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UNICUT-SAW-EP-HT (hochtemperaturfest) Hochl. Sägeschneidflüssigkeit?

The signal word is no signal word.

What is the physical form of UNICUT-SAW-EP-HT (hochtemperaturfest) Hochl. Sägeschneidflüssigkeit?

UNICUT-SAW-EP-HT (hochtemperaturfest) Hochl. Sägeschneidflüssigkeit is a flüssig with rot color. It has mild odor.