NextSDS Logo
Ta

Tangit Reiniger PVC-U/C ABS

NA: R-PHRASES Flssigkeit SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Tangit Reiniger PVC-U/C ABS

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reiniger fr Rohrverklebungen

Overview

Tangit Reiniger PVC-U/C ABS is a flssigkeit niedrig viskos, farblos, klar substance commonly used reiniger fr rohrverklebungen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

na: r-phrases

Hazard Classifications

Flam. Liq.
Eye Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel & Cie AG

manufacturer

πŸ“

Salinenstrae 61 4133 Pratteln Schweiz

🌍

CH

πŸ“ž

+41 (61) 825 70 00

πŸ“ 

+41 (61) 825 74 46

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Henkel-Werkfeuerwehr

πŸ“ž

++49-(0)211-797-3350

🌍

DE

πŸ•’

Tag und Nacht

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Reiniger; Mischung organischer Lsemittel.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aceton
EC: 200-662-2
67-64-1 50-55% ⚠️ Hazardous
Butanon
EC: 201-159-0
78-93-3 45-50% ⚠️ Hazardous

Composition Notes

Vollstndiger Wortlaut der R-Stze, die als Krzel aufgefhrt werden, siehe Kapitel 16 'Sonstige Angaben'. Fr Stoffe ohne Einstufung knnen lnderspezifische Arbeitsplatzgrenzwerte vorhanden sein.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Bei Einatmen von Dmpfen: frische Luft.

πŸ–οΈ Skin Contact

Splung mit flieendem Wasser und Seife. Hautpflege. Beschmutzte, getrnkte Kleidung sofort ausziehen.

πŸ‘οΈ Eye Contact

Sofortige Splung mit Wasser, Verband mit steriler Gaze anlegen, Facharzt aufsuchen.

🍽️ Ingestion/Swallowing

Splung der Mundhhle, trinken von 1-2 Glsern Wasser, kein Erbrechen auslsen, Arzt konsultieren.

🚨 Immediate Medical Attention Required

Bei Beschwerden Arzt aufsuchen. Facharzt aufsuchen. Arzt konsultieren.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Flssigkeit
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Flssigkeit niedrig viskos, farblos, klar
🎨 Colour
farblos
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
niedrig viskos
πŸ‘ƒ Odor
nach Methylethylketon
πŸ“Š Odor Threshold
Not available
πŸ§ͺ Ph
Not available
🧊 Melting Point
Not available
πŸ’¨ Boiling Point
56 (132.8 F)
Critical Property
πŸ”₯ Flash Point
-16 (3.2 F)
Critical Property
πŸ“Š Freezing Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ’¨ Vapor Pressure
Not available
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
Not available
πŸ“Š Bulk Density
Not available
βš–οΈ Density
0,792 - 0,802 g/cm3
Critical Property
πŸ”₯ Flammability
Not available
πŸ“Š Upper Explosive Limit
14,3 %(V)
πŸ“Š Lower Explosive Limit
1,5 %(V)
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Not available
πŸ“Š Decomposition Temperature
Not available
πŸ’§ Solubility
mischbar
πŸ“Š Partition Coefficient
Not available
πŸ“Š Solubility In Water
mischbar
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Fr gute Be- und Entlftung sorgen. Dmpfe direkt an der Entstehungs- und Austrittstelle absaugen. Bei regelmigen Arbeiten Tischabsauganlage vorsehen.

🧀 Hand Protection

Fr den Kurzzeitkontakt (1-5 Minuten) werden Schutzhandschuhe nach EN 374 aus Spezial-Nitril empfohlen (Hersteller z.B. deutsche Firma KCL, Typ Dermatril P). Bei Vollkontakt werden Schutzhandschuhe aus Butylkautschuk nach EN 374 empfohlen. Hersteller z.B. deutsche Firma KCL, Typ Butoject 898. Materialstrke > 0,7 mm Durchbruchzeit > 240 Minuten Fr den lngeren und wiederholten Kontakt ist zu beachten, dass die oben genannten Durchdringungszeiten in der Praxis deutlich krzer sein knnen, als die nach der EN 374 ermittelten. Der Schutzhandschuh sollte in jedem Falle auf seine arbeitsplatzspezifische Eignung (z.B. mechanische und thermische Bestndigkeit, Produktvertrglichkeit, Antistatik etc.) geprft werden. Bei ersten Abnutzungserscheinungen ist der Schutzhandschuh sofort zu ersetzen. Die Angaben des Handschuhherstellers sowie die jeweiligen BG Regeln sind in jedem Falle zu beachten. Wir empfehlen, einen auf die betrieblichen Belange abgestimmten Handpflegeplan in Zusammenarbeit mit einem Handschuhhersteller sowie der Berufsgenossenschaft zu erstellen.

πŸ‘οΈ Eye Protection

Dicht schlieende Schutzbrille.

😷 Respiratory Protection

Bei kurzfristiger oder geringer Exposition Atemfiltergert, bei intensiver bzw. lngerer Exposition umluftunabhngiges Atemschutzgert verwenden. Filter: A1 - A3 (braun)

🦺 Skin/Body Protection

Geeignete Schutzkleidung

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1224

πŸ“¦ Proper Shipping Name

KETONE, FLSSIG, N.A.G.

⚠️ Transport Hazard Class

3

πŸ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Tangit Reiniger PVC-U/C ABS?

The signal word for this substance is "na: r-phrases".

What is the physical form of Tangit Reiniger PVC-U/C ABS?

Tangit Reiniger PVC-U/C ABS is a flssigkeit appearing as flssigkeit niedrig viskos, farblos, klar with farblos color. It has nach methylethylketon odor.

What is the solubility of Tangit Reiniger PVC-U/C ABS?

mischbar

What is Tangit Reiniger PVC-U/C ABS used for?

Reiniger fr Rohrverklebungen