NextSDS Logo
Safety Data Sheet DE

Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur

CAS 75-05-8

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur
Product Code
1.00030, 100030
Chemical Name
Acetonitril

Regulatory Identifiers

CAS Number
75-05-8 Check regulations →
REACH No.
01-2119471307-38-XXXX

Identified Uses

Chemische Analytik, Analytische und präparative Chromatographie

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

Frankfurter Str. 250, D-64271 DARMSTADT

+49 (0)6151 72-0

Emergency Contacts

Werkfeuerwehr

+49 (0)6151/722440

Vergiftungs-Informations-Zentrale Freiburg

49(0)76119240

CHEMTREC Deutschland

0800 181 7059

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H332
Acute Tox. Cat. 4 H312
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Flüssigkeit und Dampf leicht entzündbar.
H302 + H312 + H332 Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
H319 Verursacht schwere Augenreizung.

Precautionary Statements

P210 Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P280 Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz.
P301 + P312 BEI VERSCHLUCKEN: Bei Unwohlsein GIFTINFORMATIONSZENTRUM/ Arzt anrufen.
P303 + P361 + P353 BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen.
P305 + P351 + P338 BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen.
BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Bei Unwohlsein GIFTINFORMATIONSZENTRUM/ Arzt anrufen.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Acetonitril EC: 200-835-2 75-05-8 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Nach Einatmen: Frischluft. Bei Atemstillstand: Atemspende oder Gerätebeatmung. Ggf. Sauerstoffzufuhr. Sofort Arzt hinzuziehen.

Skin contact

Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen/ duschen. Arzt konsultieren.

Eye contact

Mit reichlich Wasser ausspülen. Augenarzt hinzuziehen. Kontaktlinsen entfernen.

Ingestion

Sofort Wasser trinken lassen (maximal 2 Trinkgläser). Arzt konsultieren.

Immediate Medical Attention

Sofort Arzt hinzuziehen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Wasser, Schaum, Kohlendioxid (CO2), Löschpulver

Unsuitable media

Für diesen Stoff/ dieses Gemisch existieren keine Löschmittel-Einschränkungen.

Specific hazards

Brennbar. Dämpfe sind schwerer als Luft und breiten sich über dem Boden aus. Im Brandfall Entstehung gefährlicher Brandgase oder Dämpfe möglich. Explosionsfähige Gemische mit Luft sind schon bei Normaltemperaturen möglich.

Instructions

Hautkontakt durch Einhalten eines Sicherheitsabstandes oder Tragen geeigneter Schutzkleidung vermeiden.

Firefighter Protection

Aufenthalt im Gefahrenbereich nur mit umluftunabhängigem Atemschutzgerät. Hautkontakt durch Einhalten eines Sicherheitsabstandes oder Tragen geeigneter Schutzkleidung vermeiden.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Gefahrenzone räumen, Vorgehen nach Notfallplan, Sachkundige hinzuziehen.

Environmental

Explosionsrisiko.

Cleanup methods

Mit flüssigkeitsbindendem Material, z.B. Chemizorb® aufnehmen. Der Entsorgung zuführen. Nachreinigen.

Materials: flüssigkeitsbindendem Material, z.B. Chemizorb®

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Arbeiten unter Abzug vornehmen. Stoff/Gemisch nicht einatmen. Entwicklung von Dämpfen/Aerosolen vermeiden.

Storage

Behälter dicht verschlossen an einem trockenen, gut belüfteten Ort aufbewahren. Empfohlene Lagertemperatur siehe Produktetikett.

Hygiene

Kontaminierte Kleidung sofort wechseln. Vorbeugender Hautschutz. Nach Arbeitsende Hände und Gesicht waschen.

Fire prevention

Von offenen Flammen, heißen Oberflächen und Zündquellen fernhalten. Maßnahmen gegen elektrostatische Entladungen treffen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Vollkontakt: Material: Butylkautschuk, Minimale Schichtdicke: 0,7 mm, Durchbruchzeit: 480 min, Material getestet: Butoject® (KCL 898). Spritzkontakt: Material: Chloropren, Minimale Schichtdicke: 0,65 mm, Durchbruchzeit: 10 min, Material getestet: KCL 720 Camapren®.

Eyes

Sicherheitsbrille. Verwenden Sie zum Augenschutz nur Equipment, dass nach behördlichen Standards, wie NIOSH (US) oder EN 166 (EU), getestet und zugelassen wurde.

Respiratory

Empfohlener Filtertyp: Filter A. Der Unternehmer hat dafür zu sorgen, dass Instandhaltung, Reinigung und Prüfung von Atemschutzgeräten nach den Benutzerinformationen des Herstellers ausgeführt und entsprechend dokumentiert werden.

Skin/Body

Flammenhemmende antistatische Schutzkleidung.

Environmental

Nicht in die Kanalisation gelangen lassen. Explosionsrisiko.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
farblos
Colour Intensity
---
Form
---
Odor
nach Ether
Odor Threshold
---
Ph
---
Melting Point
-45,7 °C
Boiling Point
81,0 - 82,0 °C bei 1.013,25 hPa
Flash Point
2,0 °C - geschlossener Tiegel
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
98,64 hPa bei 20 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,78 g/cm³ bei 20 °C
Flammability
---
Upper Explosive Limit
16 % (V)
Lower Explosive Limit
4,4 % (V)
Explosive Limits
---
Auto Ignition Temperature
524,0 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
log Pow: -0,54 bei 25 °C - Bioakkumulation ist nicht zu erwarten.
Solubility In Water
1.000 g/l bei 25 °C vollkommen löslich
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
0,350 Pa·s bei 20,00 °C
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Das Produkt ist unter normalen Umgebungsbedingungen (Raumtemperatur) chemisch stabil.

Reactivity

Dämpfe können mit Luft ein explosionsfähiges Gemisch bilden.

Hazardous reactions

Heftige Reaktionen möglich mit: Starke Basen, starke Reduktionsmittel. Explosionsgefahr mit: Nitrate, Perchlorate, Perchlorsäure, konz. Schwefelsäure (mit Hitze). Entzündungsgefahr bzw. Entstehung entzündlicher Gase oder Dämpfe mit: Oxidationsmittel, Salpetersäure, Stickstoffdioxid (mit Katalysator). Entwicklung gefährlicher Gase oder Dämpfe mit: Säuren.

Avoid

Erwärmung.

Incompatible

Gummi, verschiedene Kunststoffe, Starke Oxidationsmittel

Decomposition

Im Brandfall: siehe Kapitel 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Toxizität gegenüber Fischen Durchflusstest LC50 - Pimephales promelas (fettköpfige Elritze) - 1.640 mg/l - 96 h Anmerkungen: (ECHA)

12.1 Toxizität

Toxizität gegenüber Algen statischer Test NOEC - Phaeodactylum tricornutum - 400 mg/l - 72 h (ISO 10253) statischer Test ErC50 - Phaeodactylum tricornutum - 9.696 mg/l - 72 h (ISO 10253)

12.1 Toxizität

Toxizität gegenüber Fischen (Chronische Toxizität) Durchflusstest NOEC - Oryzias latipes - 102 mg/l - 21 d (OECD- Prüfrichtlinie 204)

12.2 Persistenz und Abbaubarkeit

Biologische Abbaubarkeit Ergebnis: 70 % - Leicht biologisch abbaubar. (OECD Prüfrichtlinie 310)

12.3 Bioakkumulationspotenzial

12.3 Bioakkumulationspotenzial

Eine Bioakkumulation ist nicht zu erwarten (log Pow <= 4).

Eine Bioakkumulation ist nicht zu erwarten.

12.4 Mobilität im Boden

Adsorption am Boden nicht zu erwarten.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Dieser Stoff/diese Mischung enthält keine Komponenten in Konzentrationen von 0,1 % oder höher, die entweder als persistent, bioakkumulierbar und toxisch (PBT) oder sehr persistent und sehr bioakkumulierbar (vPvB) eingestuft sind.

Der Stoff/die Mischung enthält keine PBT- oder vPvB-Komponenten in Konzentrationen von 0,1 % oder höher.

12.6 Endokrinschädliche Eigenschaften

Der Stoff/dieses Gemisch enthält keine Bestandteile, die gemäß REACH Artikel 57(f) oder der delegierten Verordnung (EU) 2017/2100 der Kommission oder der delegierten Verordnung (EU) 2018/605 der Kommission in Mengen von 0,1 % oder mehr endokrinschädliche Eigenschaften aufweisen.

Der Stoff/dieses Gemisch enthält keine Bestandteile mit endokrinschädlichen Eigenschaften in Mengen von 0,1 % oder mehr.

12.7 Andere schädliche Wirkungen

Biologische Effekte: Gefahr für Trinkwasser. Ein Eintrag in die Umwelt ist zu vermeiden. Freisetzung in die Umwelt vermeiden. Stabilität im Wasser DT50 - > 9.999 d pH-Wert 7 bei 25 °C Anmerkungen: (berechnet)Hydrolysiert langsam.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Produktreste sind unter Beachtung der nationalen und regionalen Vorschriften zu entsorgen. Chemikalien in Originalbehältern belassen. Nicht mit anderen Abfällen vermischen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1648
Shipping Name
ACETONITRIL
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Dieses Sicherheitsdatenblatt erfüllt die Anforderungen der Verordnung (EG) Nr. 1907/2006.

Chemical Safety Assessment Not performed

Beschäftigungsbeschränkungen nach Mutterschutzrichtlinie 92/85/EWG oder verschärfenden nationalen Bestimmungen beachten, soweit zutreffend. Beschäftigungsbeschränkungen nach den Jugendarbeitsschutzbestimmungen (94/33/EG) beachten.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur?

The signal word is danger.

What is the physical form of Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur?

Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur is a flüssig with farblos color. It has nach ether odor.

What is Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur used for?

Chemische Analytik, Analytische und präparative Chromatographie

What are the hazard statements for Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur?

This substance has 3 hazard statements:

  • H225: Flüssigkeit und Dampf leicht entzündbar.
  • H302 + H312 + H332: Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
  • H319: Verursacht schwere Augenreizung.

What is the melting point of Acetonitril gradient grade für die Flüssigkeitschromatographie LiChrosolv® Reag. Ph Eur?

The melting point is -45,7 °C and the boiling point is 81,0 - 82,0 °C bei 1.013,25 hPa.