NextSDS Logo
Safety Data Sheet DE

Acetonitril hypergrade für LC-MS LiChrosolv®

CAS 75-05-8

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Acetonitril hypergrade für LC-MS LiChrosolv®
Product Code
1.00029, 100029
Chemical Name
Acetonitril

Regulatory Identifiers

CAS Number
75-05-8 Check regulations →
REACH No.
01-2119471307-38-XXXX

Identified Uses

Chemische Analytik

Manufacturers & Suppliers

M

Merck KGaA

manufacturer

Frankfurter Str. 250, D-64271 DARMSTADT

+49 (0)6151 72-0

Emergency Contacts

Werkfeuerwehr

+49 (0)6151/722440

Vergiftungs-Informations-Zentrale Freiburg

49(0)76119240

CHEMTREC Deutschland

0800 181 7059

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H332
Acute Tox. Cat. 4 H312
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Flüssigkeit und Dampf leicht entzündbar.
H302 + H312 + H332 Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
H319 Verursacht schwere Augenreizung.

Precautionary Statements

P210 Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen.
P280 Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz.
P301 + P312 BEI VERSCHLUCKEN: Bei Unwohlsein GIFTINFORMATIONSZENTRUM/ Arzt anrufen.
P303 + P361 + P353 BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen.
P305 + P351 + P338 BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen.
BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Bei Unwohlsein GIFTINFORMATIONSZENTRUM/ Arzt anrufen.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Acetonitril EC: 200-835-2 75-05-8 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Nach Einatmen: Frischluft. Bei Atemstillstand: Atemspende oder Gerätebeatmung. Ggf. Sauerstoffzufuhr. Sofort Arzt hinzuziehen.

Skin contact

Nach Hautkontakt: Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen/ duschen. Arzt konsultieren.

Eye contact

Nach Augenkontakt: Mit reichlich Wasser ausspülen. Augenarzt hinzuziehen. Kontaktlinsen entfernen.

Ingestion

Nach Verschlucken: Sofort Wasser trinken lassen (maximal 2 Trinkgläser). Arzt konsultieren.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Wasser, Schaum, Kohlendioxid (CO2), Löschpulver

Unsuitable media

Für diesen Stoff/ dieses Gemisch existieren keine Löschmittel-Einschränkungen.

Specific hazards

Kohlenstoffoxide, Stickoxide (NOx), Brennbar. Im Brandfall kann Folgendes freigesetzt werden: Stickstoffoxide, Cyanwasserstoff (Blausäure). Dämpfe sind schwerer als Luft und breiten sich über dem Boden aus. Im Brandfall Entstehung gefährlicher Brandgase oder Dämpfe möglich. Explosionsfähige Gemische mit Luft sind schon bei Normaltemperaturen möglich.

Instructions

Aufenthalt im Gefahrenbereich nur mit umluftunabhängigem Atemschutzgerät. Hautkontakt durch Einhalten eines Sicherheitsabstandes oder Tragen geeigneter Schutzkleidung vermeiden.

Firefighter Protection

Aufenthalt im Gefahrenbereich nur mit umluftunabhängigem Atemschutzgerät. Hautkontakt durch Einhalten eines Sicherheitsabstandes oder Tragen geeigneter Schutzkleidung vermeiden.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Dampf/ Aerosol nicht einatmen. Substanzkontakt vermeiden. Gefahrenzone räumen, Vorgehen nach Notfallplan, Sachkundige hinzuziehen.

Environmental

Explosionsrisiko.

Cleanup methods

Mit flüssigkeitsbindendem Material, z.B. Chemizorb® aufnehmen. Nachreinigen.

Materials: flüssigkeitsbindendem Material, z.B. Chemizorb®

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Arbeiten unter Abzug vornehmen. Stoff/Gemisch nicht einatmen. Entwicklung von Dämpfen/Aerosolen vermeiden.

Storage

Behälter dicht verschlossen an einem trockenen, gut belüfteten Ort aufbewahren. Von Hitze- und Zündquellen fernhalten.

Hygiene

Kontaminierte Kleidung sofort wechseln. Vorbeugender Hautschutz. Nach Arbeitsende Hände und Gesicht waschen.

Fire prevention

Von offenen Flammen, heißen Oberflächen und Zündquellen fernhalten.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Vollkontakt: Material: Butylkautschuk, Minimale Schichtdicke: 0,7 mm, Durchbruchzeit: 480 min, Material getestet: Butoject® (KCL 898). Spritzkontakt: Material: Chloropren, Minimale Schichtdicke: 0,65 mm, Durchbruchzeit: 10 min, Material getestet: KCL 720 Camapren®. Diese Empfehlung gilt nur für das im Sicherheitsdatenblatt genannte Produkt, das von uns geliefert wird und den von uns angegebenen Verwendungszweck. Bei der Lösung in oder bei der Vermischung mit anderen Substanzen und bei von der EN374 abweichenden Bedingungen müssen Sie sich an den Lieferanten von CE-genehmigten Handschuhen wenden (z.B. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Verwenden Sie zum Augenschutz nur Equipment, dass nach behördlichen Standards, wie NIOSH (US) oder EN 166 (EU), getestet und zugelassen wurde. Sicherheitsbrille

Respiratory

Empfohlener Filtertyp: Filter A. Der Unternehmer hat dafür zu sorgen, dass Instandhaltung, Reinigung und Prüfung von Atemschutzgeräten nach den Benutzerinformationen des Herstellers ausgeführt und entsprechend dokumentiert werden

Skin/Body

Flammenhemmende antistatische Schutzkleidung.

Environmental

Nicht in die Kanalisation gelangen lassen. Explosionsrisiko.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
farblos
Colour Intensity
---
Form
---
Odor
nach Ether
Odor Threshold
---
Ph
Keine Daten verfügbar
Melting Point
Schmelzpunkt/Schmelzbereich: -45,7 °C bei 1.013 hPa
Boiling Point
81,0 - 82,0 °C bei 1.013,25 hPa
Flash Point
2,0 °C - geschlossener Tiegel
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
98,64 hPa bei 20 °C
Vapor Density
---
Relative Density
Keine Daten verfügbar
Bulk Density
---
Density
0,78 g/cm³ bei 20 °C
Flammability
Keine Daten verfügbar
Upper Explosive Limit
16 % (V)
Lower Explosive Limit
4,4 % (V)
Explosive Limits
---
Auto Ignition Temperature
524,0 °C
Decomposition Temperature
Keine Daten verfügbar
Solubility
---
Partition Coefficient
log Pow: -0,54 bei 25 °C - Bioakkumulation ist nicht zu erwarten.
Solubility In Water
1.000 g/l bei 25 °C vollkommen löslich
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
0,350 Pa.s bei 20,00 °C
Kinematic Viscosity
Keine Daten verfügbar
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Das Produkt ist unter normalen Umgebungsbedingungen (Raumtemperatur) chemisch stabil.

Reactivity

Dämpfe können mit Luft ein explosionsfähiges Gemisch bilden.

Hazardous reactions

Heftige Reaktionen möglich mit: Starke Basen, starke Reduktionsmittel. Explosionsgefahr mit: Nitrate, Perchlorate, Perchlorsäure, konz. Schwefelsäure, Hitze. Entzündungsgefahr bzw. Entstehung entzündlicher Gase oder Dämpfe mit: Oxidationsmittel, Salpetersäure, Stickstoffdioxid, Katalysator. Entwicklung gefährlicher Gase oder Dämpfe mit: Säuren

Avoid

Hitze

Incompatible

Starke Basen, starke Reduktionsmittel, Nitrate, Perchlorate, Perchlorsäure, konz. Schwefelsäure, Oxidationsmittel, Salpetersäure, Stickstoffdioxid, Katalysator, Säuren

Decomposition

Im Brandfall: siehe Kapitel 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Toxizität gegenüber Fischen Durchflusstest LC50 - Pimephales promelas (fettköpfige Elritze) - 1.640 mg/l - 96 h Anmerkungen: (ECHA) Toxizität gegenüber Algen statischer Test NOEC - Phaeodactylum tricornutum - 400 mg/l - 72 h (ISO 10253) statischer Test ErC50 - Phaeodactylum tricornutum - 9.696 mg/l - 72 h (ISO 10253) Toxizität gegenüber Bakterien Toxizität gegenüber Fischen (Chronische Toxizität) Durchflusstest NOEC - Oryzias latipes - 102 mg/l - 21 d (OECD- Prüfrichtlinie 204)

12.2 Persistenz und Abbaubarkeit

Biologische Abbaubarkeit Ergebnis: 70 % - Leicht biologisch abbaubar. (OECD Prüfrichtlinie 310)

12.3 Bioakkumulationspotenzial

Eine Bioakkumulation ist nicht zu erwarten (log Pow <= 4).

12.4 Mobilität im Boden

Adsorption am Boden nicht zu erwarten.

Adsorption am Boden nicht zu erwarten.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Dieser Stoff/diese Mischung enthält keine Komponenten in Konzentrationen von 0,1 % oder höher, die entweder als persistent, bioakkumulierbar und toxisch (PBT) oder sehr persistent und sehr bioakkumulierbar (vPvB) eingestuft sind.

Der Stoff/die Mischung enthält keine Komponenten in Konzentrationen von 0,1 % oder höher, die als PBT oder vPvB eingestuft sind.

12.6 Endokrinschädliche Eigenschaften

Produkt: Bewertung : Der Stoff/dieses Gemisch enthält keine Bestandteile, die gemäß REACH Artikel 57(f) oder der delegierten Verordnung (EU) 2017/2100 der Kommission oder der delegierten Verordnung (EU) 2018/605 der Kommission in Mengen von 0,1 % oder mehr endokrinschädliche Eigenschaften aufweisen.

Der Stoff/dieses Gemisch enthält keine Bestandteile, die gemäß REACH Artikel 57(f) oder der delegierten Verordnung (EU) 2017/2100 der Kommission oder der delegierten Verordnung (EU) 2018/605 der Kommission in Mengen von 0,1 % oder mehr endokrinschädliche Eigenschaften aufweisen.

12.7 Andere schädliche Wirkungen

Biologische Effekte: Gefahr für Trinkwasser. Ein Eintrag in die Umwelt ist zu vermeiden. Freisetzung in die Umwelt vermeiden. Stabilität im Wasser DT50 - > 9.999 d pH-Wert 7 bei 25 °C Anmerkungen: (berechnet)Hydrolysiert langsam.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Produktreste sind unter Beachtung der nationalen und regionalen Vorschriften zu entsorgen.

Disposal

Produktreste sind unter Beachtung der nationalen und regionalen Vorschriften zu entsorgen. Chemikalien in Originalbehältern belassen. Nicht mit anderen Abfällen vermischen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1648
Shipping Name
ACETONITRIL
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Dieses Sicherheitsdatenblatt erfüllt die Anforderungen der Verordnung (EG) Nr. 1907/2006.

Chemical Safety Assessment Not performed

Beschäftigungsbeschränkungen nach Mutterschutzrichtlinie 92/85/EWG oder verschärfenden nationalen Bestimmungen beachten, soweit zutreffend. Beschäftigungsbeschränkungen nach den Jugendarbeitsschutzbestimmungen (94/33/EG) beachten.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Acetonitril hypergrade für LC-MS LiChrosolv®?

The signal word is danger.

What is the physical form of Acetonitril hypergrade für LC-MS LiChrosolv®?

Acetonitril hypergrade für LC-MS LiChrosolv® is a flüssig with farblos color. It has nach ether odor.

What is Acetonitril hypergrade für LC-MS LiChrosolv® used for?

Chemische Analytik

What are the hazard statements for Acetonitril hypergrade für LC-MS LiChrosolv®?

This substance has 3 hazard statements:

  • H225: Flüssigkeit und Dampf leicht entzündbar.
  • H302 + H312 + H332: Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
  • H319: Verursacht schwere Augenreizung.

What is the melting point of Acetonitril hypergrade für LC-MS LiChrosolv®?

The melting point is Schmelzpunkt/Schmelzbereich: -45,7 °C bei 1.013 hPa and the boiling point is 81,0 - 82,0 °C bei 1.013,25 hPa.