NextSDS Logo
Safety Data Sheet EN

Magnesium oxide

CAS 1309-48-4
EC 215-171-9

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Magnesium oxide
Product Code
10800
Chemical Name
Magnesium oxide

Regulatory Identifiers

CAS Number
1309-48-4 Check regulations →
EC Number
215-171-9 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

800-343-0660

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

866-928-0789

After normal business hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
Magnesium oxide EC: 215-171-9 1309-48-4 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) Not determined.

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU).

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type N95 (USA) or PE (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
3600 ℃ (6512 ºF)
Odor Threshold
Not determined.
Explosive Limits
---
Upper Explosive Limit
Not determined
Density
3.58 g/cm3 (29.875 lbs/gal)
Freezing Point
---
Ph
Not applicable.
Solidification Point
---
Solubility
---
Kinematic Viscosity
Not applicable.
Bulk Density
---
Melting Point
2852 ℃ (5166 °F)
Odor
Odorless
Voc Content
---
Evaporation Rate
Not applicable.
Lower Explosive Limit
Not determined
Vapor Pressure
Not applicable.
Solubility In Fat
---
Relative Density
Not determined.
Physical State Data
solid
Flash Point
---
Form
Various forms (powder/flake/crystalline/beads, etc.)
Properties Status
---
Colour Intensity
---
Molecular Weight
---
Colour
---
Partition Coefficient
Not determined.
Dynamic Viscosity
Not applicable.
Auto Ignition Temperature
Not determined.
Crystallisation Point
---
Decomposition Temperature
Not determined
Flammability
Not determined.
Appearance
Various forms (powder/flake/crystalline/beads, etc.)
Softening Point
---
Physical State
Various forms (powder/flake/crystalline/beads, etc.)
Metal Corrosion
---
Solubility In Water
Slightly soluble
State Under Standard Conditions
---
Relative Evaporation Rate
---
Vapor Density
Not applicable.
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Magnesium oxide?

The signal word is no signal word.

What is the physical form of Magnesium oxide?

Magnesium oxide is a various forms (powder/flake/crystalline/beads, etc.) appearing as various forms (powder/flake/crystalline/beads, etc.) . It has odorless odor.

What is Magnesium oxide used for?

SU24 Scientific research and development

What is the melting point of Magnesium oxide?

The melting point is 2852 ℃ (5166 °F) and the boiling point is 3600 ℃ (6512 ºF).

Compliance Scanner

Scan your compliance