Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Magnesium chloride
Product Code
M8266
Chemical Name
Magnesium chloride

Regulatory Identifiers

CAS Number
7786-30-3 Check regulations →

Identified Uses

Laboratory chemicals, Synthesis of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Inc.

manufacturer

3050 SPRUCE ST ST. LOUIS MO 63103 UNITED STATES

+1 314 771-5765

Emergency Contacts

CHEMTREC

800-424-9300

24 Hours/day; 7 Days/week

CHEMTREC

+1-703-527-3887

24 Hours/day; 7 Days/week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Store under inert gas. Hygroscopic.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Recommended Filter type: Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented. required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
crystalline
Odor
odorless
Odor Threshold
No data available
Ph
No data available
Melting Point
714 °C (1317 °F)
Boiling Point
1,412 °C 2,574 °F
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
No data available
Bulk Density
---
Density
2.32 g/mL at 25 °C (77 °F)
Flammability
The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
> 404 °C (> 759 °F) - Regulation (EC) No. 440/2008, Annex, A.16
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Not applicable for inorganic substances
Solubility In Water
468.7 g/l at 20 °C (68 °F) - soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Violent reactions possible with: acids

Avoid

When mixed with limited amount of water enough heat may be generated to cause frothing. Exposure to moisture.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Toxicity to fish static test LC50 - Pimephales promelas (fathead minnow) - 2,119.3 mg/l - 96 h (US-EPA) Toxicity to daphnia and other aquatic invertebrates static test LC50 - Daphnia magna (Water flea) - 548.4 mg/l - 48 h Remarks: (ECHA) Toxicity to algae Growth rate EC50 - Desmodesmus subspicatus (green algae) - > 100 mg/l - 72 h (OECD Test Guideline 201) Toxicity to bacteria static test EC50 - activated sludge - > 900 mg/l - 3 h (OECD Test Guideline 209) Toxicity to daphnia and other aquatic invertebrates (Chronic toxicity) semi-static test EC10 - Daphnia magna (Water flea) - 321 mg/l - 21 d Remarks: (ECHA)

12.2 Persistence and degradability

The methods for determining the biological degradability are not applicable to inorganic substances.

The methods for determining the biological degradability are not applicable to inorganic substances.

12.3 Bioaccumulative potential

No data available

No data available

12.4 Mobility in soil

No data available

No data available

12.5 Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

12.6 Endocrine disrupting properties

No data available

12.7 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste material must be disposed of in accordance with the national and local regulations.

Disposal

Leave chemicals in original containers. No mixing with other waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Magnesium chloride?

The signal word is no signal word.

What is the physical form of Magnesium chloride?

Magnesium chloride is a solid with white color. It has odorless odor.

What is Magnesium chloride used for?

Laboratory chemicals, Synthesis of substances

What is the melting point of Magnesium chloride?

The melting point is 714 °C (1317 °F) and the boiling point is 1,412 °C 2,574 °F.