NextSDS Logo
Safety Data Sheet EN

PUREQUANT AMMONIUM BISULFITE

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PUREQUANT AMMONIUM BISULFITE
Product Code
100082607

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

L

Life Technologies Corporation

manufacturer

5781 Van Allen Way, PO Box 6482, Carlsbad, CA 92008

+1 760 603 7200

L

Life Technologies

distributor

5250 Mainway Drive, Burlington, ONT, CANADA L7L 6A4

800/263-6236

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

+1 703-527-3887

CHEMTREC

+1 703-741-5970

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation

Precautionary Statements

P264 Wash hands thoroughly after handling
P280 Wear protective gloves/protective clothing/eye protection/face protection
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
P337 + P313 If eye irritation persists: Get medical advice/attention

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Ammonium hydrogensulphite EC: 233-469-7 10192-30-0 98 - 100% No

Notes

We recommend handling all chemicals with caution.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If symptoms persist, call a physician.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Immediate medical attention is required.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.

Symptoms: Causes serious eye irritation.

Ingestion

Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. Get medical attention if symptoms occur.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Wear suitable gloves. Glove material: Compatible chemical-resistant gloves.

Eyes

Tight sealing safety goggles.

Respiratory

In case of insufficient ventilation wear respirators and components tested and approved under appropriate government standards.

Skin/Body

Wear laboratory coat for body protection.

Environmental

No special environmental precautions required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Density
No data
Bulk Density
---
Upper Explosive Limit
No data
Solubility In Water
---
Decomposition Temperature
℃ No data ºF No data
Cloud Point
---
Melting Point
℃ No data ºF No data
Physical State Data
liquid
Relative Evaporation Rate
---
Odor Threshold
Mixture has not been tested
Evaporation Rate
No data
Flash Point
℃ No data ºF No data
Explosive Limits
---
Freezing Point
---
Vapor Pressure
No data
Crystallisation Point
---
Physical State
liquid
Voc Content
---
Ph
Mixture has not been tested
Vapor Density
No data
Colour Intensity
---
Form
---
Kinematic Viscosity
---
Colour
---
Flammability
Not Applicable
Metal Corrosion
---
Solubility
Mixture has not been tested
Solubility In Fat
---
Dynamic Viscosity
---
Softening Point
---
Solidification Point
---
State Under Standard Conditions
---
Lower Explosive Limit
No data
Properties Status
---
Auto Ignition Temperature
℃ No data ºF No data
Partition Coefficient
No data
Appearance
liquid
Odor
Mixture has not been tested
Molecular Weight
Not Applicable
Density
No data
Boiling Point
℃ No data ºF No data
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PUREQUANT AMMONIUM BISULFITE?

The signal word is warning.

What is the physical form of PUREQUANT AMMONIUM BISULFITE?

PUREQUANT AMMONIUM BISULFITE is a liquid appearing as liquid . It has mixture has not been tested odor.

What is the solubility of PUREQUANT AMMONIUM BISULFITE?

Mixture has not been tested

What are the hazard statements for PUREQUANT AMMONIUM BISULFITE?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation

What is the melting point of PUREQUANT AMMONIUM BISULFITE?

The melting point is ℃ No data ºF No data and the boiling point is ℃ No data ºF No data.

Compliance Scan

Free compliance check