Product Information

Product Name
Di-n-propyl ether
Product Code
B21423

Regulatory Identifiers

CAS Number
111-43-3 Check regulations →
EC Number
203-869-6 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapor.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
Di-n-propyl ether EC: 203-869-6 111-43-3 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

Immediate Medical Attention

Seek immediate medical advice.

Medical Treatment

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

If this product is involved in a fire, the following can be released: Carbon monoxide and carbon dioxide

Firefighter Protection

Wear self-contained respirator. Wear fully protective impervious suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow product to reach sewage system or any water course.

Cleanup methods

Absorb with liquid-binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly sealed. Open and handle container with care.

Storage

Store in cool, dry place in tightly closed containers. Store in a cool location.

Fire prevention

Protect against electrostatic charges. Keep ignition sources away.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer.

Eyes

Safety glasses

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Flash Point
-28 °C (-18 °F)
Solubility In Water
Not determined
Vapor Density
Not determined.
Solubility
Not determined
Boiling Point
90-91 °C (194-196 °F)
Explosive Limits
---
Molecular Weight
---
Voc Content
---
Density
0.747 g/cm³ (6.234 lbs/gal)
Kinematic Viscosity
Not determined.
Properties Status
---
Dynamic Viscosity
Not determined.
Crystallisation Point
---
Colour
---
Physical State Data
liquid
Relative Evaporation Rate
---
Lower Explosive Limit
Not determined
Softening Point
---
Colour Intensity
---
Metal Corrosion
---
State Under Standard Conditions
---
Ph
Not determined.
Melting Point
-122 °C (-188 °F)
Odor
Not determined
Solidification Point
---
Partition Coefficient
Not determined.
Odor Threshold
Not determined.
Appearance
Not determined
Freezing Point
---
Form
Liquid
Flammability
Not determined.
Physical State
Liquid
Decomposition Temperature
Not determined
Auto Ignition Temperature
Not determined
Vapor Pressure
Not determined
Bulk Density
---
Cloud Point
---
Relative Density
Not determined.
Evaporation Rate
Not determined.
Upper Explosive Limit
Not determined
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

May form explosive peroxides.

Hazardous reactions

Reacts with strong oxidizing agents. May form explosive peroxides.

Avoid

No further relevant information available.

Incompatible

Oxidizing agents

Decomposition

Carbon monoxide and carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consult state, local or national regulations to ensure proper disposal.

Disposal

Consult state, local or national regulations to ensure proper disposal.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN2384
Shipping Name
Di-n-propyl ether
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids

IMDG

Warning: Flammable liquids

IATA

Warning: Flammable liquids

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

For use only by technically qualified individuals.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Di-n-propyl ether?

The signal word is danger.

What is the physical form of Di-n-propyl ether?

Di-n-propyl ether is a liquid appearing as not determined . It has not determined odor.

What is the solubility of Di-n-propyl ether?

Not determined

What is Di-n-propyl ether used for?

SU24 Scientific research and development

What are the hazard statements for Di-n-propyl ether?

This substance has 2 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Di-n-propyl ether?