NextSDS Logo
Safety Data Sheet EN

Antimony lump

CAS 7440-36-0
EC 231-146-5

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Antimony lump
Product Form
lump
Product Code
00016

Regulatory Identifiers

CAS Number
7440-36-0 Check regulations →
EC Number
231-146-5 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

After normal business hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
Antimony EC: 231-146-5 7440-36-0 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer.

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

Respiratory

Use suitable respirator when high concentrations are present.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
Not applicable.
Molecular Weight
---
Vapor Pressure
Not applicable.
Flammability
Not determined.
Colour Intensity
---
Colour
---
Physical State Data
solid
Odor
Odorless
Evaporation Rate
Not applicable.
Dynamic Viscosity
Not applicable.
Metal Corrosion
---
Solidification Point
---
Cloud Point
---
Solubility In Water
Insoluble
Physical State
solid
Explosive Limits
---
Density
6.68 g/cm³ (55.745 lbs/gal)
Solubility In Fat
---
State Under Standard Conditions
---
Solubility
Insoluble
Flash Point
---
Freezing Point
---
Boiling Point
1587 °C (2889 °F)
Softening Point
---
Relative Density
Not determined.
Odor Threshold
Not determined.
Properties Status
---
Appearance
Solid in various forms
Melting Point
630.7 °C (1167 °F)
Crystallisation Point
---
Auto Ignition Temperature
Not determined
Voc Content
---
Bulk Density
---
Lower Explosive Limit
Not determined
Partition Coefficient
Not determined.
Ph
Not applicable.
Upper Explosive Limit
Not determined
Kinematic Viscosity
Not applicable.
Decomposition Temperature
Not determined
Form
Solid in various forms
Relative Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Antimony lump?

The signal word is no signal word.

What is the physical form of Antimony lump?

Antimony lump is a solid appearing as solid in various forms . It has odorless odor.

What is the solubility of Antimony lump?

Insoluble

What is Antimony lump used for?

SU24 Scientific research and development

What is the melting point of Antimony lump?

The melting point is 630.7 °C (1167 °F) and the boiling point is 1587 °C (2889 °F).