NextSDS Logo
Safety Data Sheet EN

Propionaldehyde

CAS 123-38-6
EC 204-623-0

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Propionaldehyde
Chemical Name
propanal propionaldehyde 605-018-00-8

Regulatory Identifiers

CAS Number
123-38-6 Check regulations →
EC Number
204-623-0 Check regulations →

Manufacturers & Suppliers

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

800-343-0660

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

866-928-0789

After normal business hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2A H319
STOT SE Cat. 3 H335

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapor.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P273 Avoid release to the environment.
P403 Store in a well-ventilated place.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
propanal propionaldehyde 605-018-00-8 EC: 204-623-0 123-38-6 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Symptoms: Causes skin irritation.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Symptoms: Causes serious eye irritation.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Butyl rubber, BR. Penetration time of glove material (in minutes) 343. Glove thickness: 0.3 mm

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
280 g/l Fully miscible
Cloud Point
---
Physical State
Liquid
Decomposition Temperature
Not determined.
Freezing Point
---
Properties Status
---
Colour Intensity
---
Molecular Weight
---
Dynamic Viscosity
0.375 mPas
Relative Density
Not determined.
Metal Corrosion
---
Auto Ignition Temperature
175 °C (347 ºF)
Ph
Not determined.
Vapor Density
Not determined.
Bulk Density
---
Lower Explosive Limit
2.3 Vol %
Physical State Data
liquid
Solubility In Fat
---
Crystallisation Point
---
Upper Explosive Limit
21 Vol %
Boiling Point
47-49 °C (117-120 °F)
State Under Standard Conditions
---
Solubility
280 g/l Fully miscible
Odor Threshold
Not determined.
Solidification Point
---
Explosive Limits
---
Appearance
Not determined.
Relative Evaporation Rate
---
Flash Point
-40 °C (-40 °F)
Form
Liquid
Partition Coefficient
Not determined.
Melting Point
-81 °C (-114 ºF)
Odor
Pungent
Evaporation Rate
Not determined.
Softening Point
---
Density
0.81 g/cm3 (6.759 lbs/gal)
Colour
---
Voc Content
---
Flammability
Not determined.
Vapor Pressure
343 hPa (257 mm Hg)
Kinematic Viscosity
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1275
Shipping Name
Propionaldehyde
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids

IMDG

Warning: Flammable liquids

IATA

Warning: Flammable liquids

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Propionaldehyde?

The signal word is danger.

What is the physical form of Propionaldehyde?

Propionaldehyde is a liquid appearing as not determined. . It has pungent odor.

What is the solubility of Propionaldehyde?

280 g/l Fully miscible

What are the hazard statements for Propionaldehyde?

This substance has 4 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.

What is the melting point of Propionaldehyde?

The melting point is -81 °C (-114 ºF) and the boiling point is 47-49 °C (117-120 °F).

Compliance Scanner