n-Butyl formate
Product Code
L14247
Chemical Name
Butylformiaat
Synonyms
Butyl methanoate; Formic acid butyl ester

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

n-Butyl formate (CAS: 592-84-7 ) is a colorless substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2A H319
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapor.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P210: Keep away from heat/sparks/open flames/hot surfaces. No smoking.
  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P303 + P361 + P353: If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar company logo - Safety Data Sheet supplier organization

Alfa Aesar

manufacturer

๐Ÿ“

30 Bond Street Ward Hill, MA 01835-8099

๐ŸŒ

US

๐Ÿ“ 

800-322-4757

๐ŸŒ www.alfa.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

๐Ÿ“ž

(800) 343-0660

๐ŸŒ

US

๐Ÿ•’

Monday-Friday, 8am-7pm EST

๐Ÿ’ก

During normal business hours

Carechem 24

๐Ÿ“ž

(866) 928-0789

๐ŸŒ

US

๐Ÿ’ก

After normal business hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Butylformiaat
EC: 209-772-5
592-84-7 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Colorless
๐ŸŽจ Colour
Colorless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
Not determined
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
-92 C (-134 F)
Critical Property
๐Ÿ’จ Boiling Point
105-107 C (221-225 F)
Critical Property
๐Ÿ”ฅ Flash Point
18 C (64 F)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.893 g/cm (7.452 lbs/gal)
Critical Property
๐Ÿ”ฅ Flammability
Not determined.
๐Ÿ“Š Upper Explosive Limit
Not determined
๐Ÿ“Š Lower Explosive Limit
Not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Decomposition Temperature
Not determined
๐Ÿ’ง Solubility
Not determined
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Not determined
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

๐Ÿงค Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Use suitable respirator when high concentrations are present.

๐Ÿฆบ Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1128

๐Ÿ“ฆ Proper Shipping Name

N-Butyl formate

โš ๏ธ Transport Hazard Class

3 Flammable liquids.

๐Ÿ“‹ Packing Group

II

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Flammable liquids

โœˆ๏ธ IATA Air Transport Precautions

Warning: Flammable liquids

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is n-Butyl formate known by?

n-Butyl formate is also known as: Butyl methanoate; Formic acid butyl ester

What is the hazard signal word for n-Butyl formate?

The signal word for this substance is "danger".

What is the physical form of n-Butyl formate?

n-Butyl formate is a liquid appearing as colorless with colorless color. It has not determined odor.

What is the solubility of n-Butyl formate?

Not determined

What is n-Butyl formate used for?

SU24 Scientific research and development

What are the hazard statements for n-Butyl formate?

This substance has 3 hazard statements: H225: Highly flammable liquid and vapor. H319: Causes serious eye irritation. H335: May cause respiratory irritation.

What is the melting point of n-Butyl formate?

The melting point is -92 C (-134 F) and the boiling point is 105-107 C (221-225 F).