NextSDS Logo
4,

4,4'-Diaminodiphenylmethane

DANGER Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
4,4'-Diaminodiphenylmethane
Product Code
A15645
Chemical Name
4,4'-Diaminodiphenylmethane

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

4,4'-Diaminodiphenylmethane (CAS: 101-77-9 ) is a not determined substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Muta. Category 2 H341
Carc. Category 1A H350
STOT SE Category 1 H370
STOT RE Category 2 H373
Acute Tox. Category 4 H302
Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H317: May cause an allergic skin reaction.
  • H341: Suspected of causing genetic defects.
  • H350: May cause cancer.
  • H370: Causes damage to the kidneys, the liver and the digestive system. Route of exposure: Oral, Inhalative and Dermal.
  • H373: May cause damage to the blood through prolonged or repeated exposure. Route of exposure: Oral, Inhalative, Dermal.

Precautionary Statements

  • P260: Do not breathe dust/fume/gas/mist/vapours/spray.
  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P307+P311: IF exposed: Call a POISON CENTER or doctor/physician.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

📍

30 Bond Street, Ward Hill, MA 01835-8099

🌍

US

📞

800-343-0660

📠

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

(800) 343-0660

🕒

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

📞

(866) 928-0789

🕒

After normal business hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Chemical characterization: Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
4,4'-Diaminodiphenylmethane
EC: 202-974-4
101-77-9 Not specified ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

🖐️ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

👁️ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

🍽️ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

💧 Solubility
Not available
📊 Freezing Point
Not available
🎨 Colour
Brown
💨 Evaporation Rate
Not applicable.
👃 Odor
Not determined
📊 Form
Solid
🧊 Melting Point
92-93 ℃ (198-199 ºF)
Critical Property
🔥 Flammability
Not determined.
📊 Solidification Point
Not available
📊 Decomposition Temperature
Not determined
📊 Explosive Limits
Not available
📊 Kinematic Viscosity
Not applicable.
📊 Solubility In Water
Not determined
📊 Cloud Point
Not available
👁️ Appearance
Not determined
🧪 Physical State
Solid
Critical Property
🧪 Ph
Not applicable.
📊 Lower Explosive Limit
Not determined
📊 Voc Content
Not available
🔥 Flash Point
221 °C (430 °F)
Critical Property
💨 Boiling Point
398-399 ℃ (748-750'°F)
Critical Property
📊 Relative Evaporation Rate
Not available
📊 Properties Status
Not available
💨 Vapor Pressure
Not applicable.
📊 Colour Intensity
Not available
📊 Relative Density
Not determined.
📊 State Under Standard Conditions
Not available
📊 Bulk Density
Not available
📊 Partition Coefficient
Not determined.
📊 Metal Corrosion
Not available
📊 Softening Point
Not available
⚖️ Density
1.15 g/cm3 (9.597 lbs/gal)
Critical Property
📊 Dynamic Viscosity
Not applicable.
📊 Molecular Weight
Not available
📊 Vapor Density
Not applicable.
📊 Auto Ignition Temperature
Not determined.
📊 Upper Explosive Limit
Not determined
📊 Crystallisation Point
Not available
📊 Solubility In Fat
Not available
📊 Odor Threshold
Not determined.
📊 Physical State Data
solid

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

🧤 Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) 480. Glove thickness 0.4 mm.

👁️ Eye Protection

Safety glasses.

😷 Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type P100 (USA) or P3 (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.

🦺 Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN2651

📦 Proper Shipping Name

4,4'-Diaminodiphenyl methane

⚠️ Transport Hazard Class

6.1

📋 Packing Group

III

🚛 ADR Transport Precautions

Warning: Toxic substances

🚢 IMDG Maritime Transport Precautions

Special marking with the symbol (fish and tree).

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 4,4'-Diaminodiphenylmethane?

The signal word for this substance is "danger".

What is the physical form of 4,4'-Diaminodiphenylmethane?

4,4'-Diaminodiphenylmethane is a solid appearing as not determined with brown color. It has not determined odor.

What is 4,4'-Diaminodiphenylmethane used for?

SU24 Scientific research and development

What are the hazard statements for 4,4'-Diaminodiphenylmethane?

This substance has 6 hazard statements: H302: Harmful if swallowed. H317: May cause an allergic skin reaction. H341: Suspected of causing genetic defects. H350: May cause cancer. H370: Causes damage to the kidneys, the liver and the digestive system. Route of exposure: Oral, Inhalative and Dermal. H373: May cause damage to the blood through prolonged or repeated exposure. Route of exposure: Oral, Inhalative, Dermal.

What is the melting point of 4,4'-Diaminodiphenylmethane?

The melting point is 92-93 ℃ (198-199 ºF) and the boiling point is 398-399 ℃ (748-750'°F).