NextSDS Logo
Safety Data Sheet EN

Q8 Porta 145P

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Q8 Porta 145P

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Process oil

Manufacturers & Suppliers

K

Kuwait Petroleum Companies in the Benelux

distributor

Desguinlei 100 - 8, 2018 Antwerp, Belgium

+32 3 247 38 11

K

Kuwait Petroleum Belgium N.V./S.A.

manufacturer

Petroleumkaai 7, B-2020 Antwerp, Belgium

Q

Q8Oils Italia S.r.l.

manufacturer

Via Volpedo 2, 15050 Castellar Guidobono (AL), Italy

Emergency Contacts

CARECHEM24

+44 (0) 1235 239 670

CARECHEM24

+44 (0) 1865 407 333

EN

Poison Centre

+32 (0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Severely refined mineral oil (C15 -C50) * - Not classified.

Chemical Name CAS Number Concentration Hazardous
Severely refined mineral oil (C15 -C50) --- 90% No
N/A EC: 265-101-6 64742-01-4 --- No
N/A EC: 265-157-1 64742-54-7 --- No
N/A EC: 265-160-8 64742-57-0 --- No
N/A EC: 265-166-0 64742-62-7 --- No
N/A EC: 265-169-7 64742-65-0 --- No

Occupational exposure limits, if available, are listed in Section 8.

Notes

The mineral base oils contained in this product are severely refined and contain less than 3% DMSO extract according to IP 346 method, and are therefore not classified as carcinogen according to Regulation (EC) No 1272/2008, note L.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No specific data.

Skin contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Adverse symptoms may include the following: irritation dryness cracking.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No specific data.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Wear suitable gloves tested to EN374. Recommended: < 1 hour (breakthrough time): nitrile rubber 0.17 mm. Provide employee with skin care programmes.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: Boiling point > 65 ℃: A1; Boiling point < 65 ℃: AX1; Hot material: A1P2. Gas and combination filter cartridges should comply with the European standard EN14387.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
Not applicable.
Form
---
Melting Point
Not applicable.
Vapor Pressure
< 0.01 kPa (<0.075006 mm Hg)
Density
0.89 g/cm3 [15°C (59ºF)] [ASTM D 4052]
Cloud Point
---
Flash Point
Closed cup: >240°℃ (>464ºF) [ASTM D 93] Open cup: >260℃ (>500°F) [ASTM D 92]
Odor
Hydrocarbon. [Slight]
Lower Explosive Limit
Not available.
Softening Point
---
Relative Density
---
Appearance
Clear ☒
Properties Status
---
Solidification Point
---
Decomposition Temperature
>250°℃
Auto Ignition Temperature
>300°C (>572°F)
Voc Content
---
Crystallisation Point
---
Freezing Point
---
Ph
Not applicable.
Colour
Yellow [Dark]
Boiling Point
>250°C (>482°F)
Solubility In Water
Not available.
Evaporation Rate
---
Dynamic Viscosity
---
Molecular Weight
---
Solubility
Not soluble in cold water, Not soluble in hot water
Solubility In Fat
---
Relative Evaporation Rate
---
Kinematic Viscosity
Kinematic (40℃ (104ºF)): 145 mm2/s (145 cSt) [ASTM D 445] Kinematic (100℃ (212ºF)): 14.2 mm2/s (14.2 cSt) [ASTM D 445]
Physical State
Liquid. [Oily liquid.]
Partition Coefficient
Not applicable.
Vapor Density
---
Colour Intensity
---
Physical State Data
liquid
Bulk Density
---
Odor Threshold
Not available.
Metal Corrosion
---
Upper Explosive Limit
Not available.
State Under Standard Conditions
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Q8 Porta 145P?

The signal word is no signal word.

What is the physical form of Q8 Porta 145P?

Q8 Porta 145P is a liquid. [oily liquid.] appearing as clear ☒ with yellow [dark] color. It has hydrocarbon. [slight] odor.

What is the solubility of Q8 Porta 145P?

Not soluble in cold water, Not soluble in hot water

What is Q8 Porta 145P used for?

Process oil

What is the melting point of Q8 Porta 145P?

The melting point is Not applicable. and the boiling point is >250°C (>482°F).