NextSDS Logo
Safety Data Sheet EN

CAT EXTREME APPLICATION GREASE 2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CAT EXTREME APPLICATION GREASE 2
Product Code
2020A0109040, 531525-60

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Grease

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

ExxonMobil Petroleum & Chemical BVBA logo

ExxonMobil Petroleum & Chemical BVBA

POLDERDIJKWEG, B-2030 Antwerpen, Belgium

+32 3 543 3111

www.msds.exxonmobil.com

Emergency Contacts

Emergency Contact

(+44) 870 8200418

Emergency Contact

(+353) 19014670

CHEMTREC

111

National Poison Control Centre

(+353)1 809 2166

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This material is defined as a mixture.

Chemical Name CAS Number Concentration Hazardous
9-OCTADECENOIC ACID (Z)-, REACTION PRODUCTS WITH DIHYDRO-3- (DODECENYL)-2,5-FURANDIONE AND TRIETHYLENETETRAMINE EC: 270-840-2 68478-81-9 0.1 - 1% Yes
BENZENE SULFONIC ACIDS, C10-16 ALKYL DERIVS., CA SALTS EC: 271-529-4 68584-23-6 1 - 5% Yes
BENZENESULFONIC ACID, MONO-C16-24- ALKYL DERIVS. CALCIUM SALTS EC: 274-263-7 70024-69-0 1 - 5% Yes
CALCIUM DODECYLBENZENE SULFONATE EC: 247-557-8 26264-06-2 5 - 10% Yes
CALCIUM HYDROXIDE EC: 215-137-3 1305-62-0 1 - 5% Yes
CARBONIC ACID, CALCIUM SALT (1:1) EC: 207-439-9 471-34-1 10 - 20% No
MOLYBDENUM (IV) SULPHIDE EC: 215-263-9 1317-33-5 5 - 10% No
SULFONIC ACIDS, PETROLEUM, CALCIUM SALTS EC: 263-093-9 61789-86-4 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.

Symptoms: Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance.

Symptoms: Irritation.

Ingestion

Seek medical attention.

Immediate Medical Attention

The need to have special means for providing specific and immediate medical treatment available in the workplace is not expected.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Chemical resistant gloves are recommended. Nitrile, minimum 0.38 mm thickness or comparable protective barrier material with a high performance level for continuous contact use conditions, permeation breakthrough minimum 480 minutes in accordance with CEN standards EN 420 and EN 374. CEN standards EN 420 and EN 374 provide general requirements and lists of glove types. Inspect and replace worn or damaged gloves.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable.

Skin/Body

Chemical/oil resistant clothing is recommended.

Environmental

Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Colour Intensity
---
Vapor Pressure
< 0.013 kPa
Relative Evaporation Rate
---
Flash Point
>200°C
Bulk Density
---
Flammability
Not technically feasible
Evaporation Rate
No data available
Cloud Point
---
Solubility
water Negligible
Partition Coefficient
> 3.5
Odor Threshold
No data available
Vapor Density
No data available
Physical State
Solid
Solidification Point
---
Solubility In Fat
---
Freezing Point
No data available
Density
---
Ph
Not technically feasible
Boiling Point
> 316°C
Auto Ignition Temperature
No data available
Metal Corrosion
---
Explosive Limits
---
Softening Point
---
Appearance
---
Lower Explosive Limit
No data available
Crystallisation Point
---
Physical State Data
liquid
Solubility In Water
Negligible
Decomposition Temperature
No data available
Relative Density
1.042
Odor
Characteristic
Colour
Dark Gray
State Under Standard Conditions
---
Melting Point
No data available
Voc Content
---
Form
Semi-fluid
Upper Explosive Limit
No data available
Kinematic Viscosity
150 cSt
Properties Status
---
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CAT EXTREME APPLICATION GREASE 2?

The signal word is no signal word.

What is the physical form of CAT EXTREME APPLICATION GREASE 2?

CAT EXTREME APPLICATION GREASE 2 is a solid with dark gray color. It has characteristic odor.

What is the solubility of CAT EXTREME APPLICATION GREASE 2?

water Negligible

What is CAT EXTREME APPLICATION GREASE 2 used for?

Grease

What is the melting point of CAT EXTREME APPLICATION GREASE 2?

The melting point is No data available and the boiling point is > 316°C.