Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CAT EXTREME APPLICATION GREASE 2
- Product Code
- 2020A0109040, 531525-60
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Grease
Uses advised against
None unless specified elsewhere in this SDS.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BVBA
POLDERDIJKWEG, B-2030 Antwerpen, Belgium
+32 3 543 3111
www.msds.exxonmobil.com
Emergency Contacts
Emergency Contact
(+44) 870 8200418
Emergency Contact
(+353) 19014670
CHEMTREC
111
National Poison Control Centre
(+353)1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This material is defined as a mixture.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 9-OCTADECENOIC ACID (Z)-, REACTION PRODUCTS WITH DIHYDRO-3-(DODECENYL)-2,5-FURANDIONE AND TRIETHYLENETETRAMINE EC: 270-840-2 | 68478-81-9 | 0.1 - 1% | Yes |
| BENZENE SULFONIC ACIDS, C10-16 ALKYL DERIVS., CA SALTS EC: 271-529-4 | 68584-23-6 | 1 - 5% | Yes |
| BENZENESULFONIC ACID, MONO-C16-24-ALKYL DERIVS. CALCIUM SALTS EC: 274-263-7 | 70024-69-0 | 1 - 5% | Yes |
| CALCIUM DODECYLBENZENE SULFONATE EC: 247-557-8 | 26264-06-2 | 5 - 10% | Yes |
| CALCIUM HYDROXIDE EC: 215-137-3 | 1305-62-0 | 1 - 5% | Yes |
| CARBONIC ACID, CALCIUM SALT (1:1) EC: 207-439-9 | 471-34-1 | 10 - 20% | No |
| MOLYBDENUM (IV) SULPHIDE EC: 215-263-9 | 1317-33-5 | 5 - 10% | No |
| SULFONIC ACIDS, PETROLEUM, CALCIUM SALTS EC: 263-093-9 | 61789-86-4 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Symptoms: Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.
Flush thoroughly with water. If irritation occurs, get medical assistance.
Symptoms: Irritation.
Seek medical attention.
Immediate Medical Attention
The need to have special means for providing specific and immediate medical treatment available in the workplace is not expected.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Hazardous Combustion Products: Aldehydes, Incomplete combustion products, Oxides of carbon, Smoke, Fume, Sulphur oxides
Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind areas if required, due to toxicity or flammability of the material.
Normal antistatic work clothes are usually adequate.
Full body suit of chemical resistant, antistatic material is recommended.
Prevent entry into waterways, sewers, basements or confined areas.
Scrape up spilled material with shovels into a suitable container for recycle or disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid all personal contact. Prevent small spills and leakage to avoid slip hazard.
Do not store in open or unlabelled containers.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Chemical resistant gloves are recommended. Nitrile, minimum 0.38 mm thickness or comparable protective barrier material with a high performance level for continuous contact use conditions, permeation breakthrough minimum 480 minutes in accordance with CEN standards EN 420 and EN 374. CEN standards EN 420 and EN 374 provide general requirements and lists of glove types. Inspect and replace worn or damaged gloves.
If contact is likely, safety glasses with side shields are recommended.
No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable.
Chemical/oil resistant clothing is recommended.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.6. OTHER ADVERSE EFFECTS
No adverse effects are expected.
12.1. TOXICITY
Material is expected to be harmful to aquatic organisms.
12.2. PERSISTENCE AND DEGRADABILITY
Base oil component is expected to be inherently biodegradable.
12.3. BIOACCUMULATIVE POTENTIAL
Base oil component has the potential to bioaccumulate, but metabolism or physical properties may reduce bioconcentration or limit bioavailability.
12.4. MOBILITY IN SOIL
The base oil component has low solubility, floats, and is expected to migrate from water to land, partitioning to sediment and wastewater solids.
12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)
The material does not meet the criteria for PBT or vPvB.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Applicable EU Directives and Regulations: 1907/2006 and 1272/2008
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CAT EXTREME APPLICATION GREASE 2?
The signal word is no signal word.
What is the physical form of CAT EXTREME APPLICATION GREASE 2?
CAT EXTREME APPLICATION GREASE 2 is a solid with dark gray color. It has characteristic odor.
What is the solubility of CAT EXTREME APPLICATION GREASE 2?
water Negligible
What is CAT EXTREME APPLICATION GREASE 2 used for?
Grease
What is the melting point of CAT EXTREME APPLICATION GREASE 2?
The melting point is No data available and the boiling point is > 316°C.