NextSDS Logo
Safety Data Sheet EN

Lithium-Ion Rechargeable Battery Pack

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lithium-Ion Rechargeable Battery Pack
Product Code
BL1021B

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

M

Makita U.S.A., Inc.

manufacturer

14930-C Northam Street La Mirada, CA 90638

1-510-657-9881

Emergency Contacts

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Battery Cell; Circuit Module; Plastic Parts and Paints

Chemical Name CAS Number Concentration Hazardous
Aluminum Foil 7429-90-5 2 - 10% Yes
Metal Oxide (proprietary) --- 20 - 50% Yes
Polyvinylidene Fluoride (PVDF) 24937-79-9 5% Yes
Copper Foil 7440-50-8 2 - 10% Yes
Carbon (proprietary) 7440-44-0 10 - 30% Yes
Electrolyte (proprietary) --- 10 - 20% Yes
Stainless steel, Nickel and inert materials Remainder N/A --- --- Yes
Lead 7439-92-1 0.001% Yes
Mercury 7439-97-6 --- Yes
Chromium 7440-47-3 --- Yes
Cadmium 7440-43-9 --- Yes
Plastic case and Si2O --- --- Yes
Lead 7439-92-1 0.1% Yes
Nickle 7440-02-0 0.01% Yes
CFCs 75-69-4 --- Yes
Polyclorinated Biphenyls 1336-36-3 --- Yes

Watt-hour rating: Under 100 WH

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Leave area immediately and seek medical attention.

Skin contact

Wash area thoroughly with soap and water and seek medical attention.

Eye contact

Rinse eyes with water for 15 minutes and seek medical attention.

Ingestion

If swallowed, obtain medical attention immediately. Drink milk/water and induce vomiting; seek medical attention.

Immediate Medical Attention

Seek medical attention immediately for all exposure routes.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing media suitable for the materials that are burning.

Specific hazards

Cell is not flammable but internal organic material will burn if the cell is incinerated. If heated above 125°C, cell(s) can explode/vent.

Instructions

If possible, remove cell(s) from firefighting area.

Firefighter Protection

Use NIOSH/MSHA approved full-face self-contained breathing apparatus (SCBA) with full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special protective clothing required for handling individual cells.

Storage

Store in a cool, dry place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Not required for handling of cells.

Eyes

Not required beyond safety practices of employer.

Respiratory

Not required during normal operations. SCBA required in the event of a fire.

Skin/Body

Steel toed shoes recommended for large container handling.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

heat, open flame

Incompatible

corrosives

Decomposition

None during normal operating conditions. If cells are opened, hydrogen fluoride and carbon monoxide may be released.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.2 Persistence and degradability

12.3 Bioaccumulative potential

Some materials within the cell are bio-accumulative.

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

Under normal conditions, these materials are contained and pose no risk to persons or the surrounding environment.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of according to all federal, state, and local regulations.

Waste Codes

Non-regulated RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3480, 3481
Shipping Name
Lithium-ion batteries
Transport Class
9
Packing Group
II
ADR

When a number of batteries are transported by ship, vehicle and railroad avoid high temperature and dew condensation. Avoid transportation which may cause damage of package.

IMDG

When a number of batteries are transported by ship, vehicle and railroad avoid high temperature and dew condensation. Avoid transportation which may cause damage of package.

IATA

Lithium ion cells and batteries must be offered for transport at a state of charge not exceeding 30 per cent of their rated capacity. UN 3480, PI 965, Section IA and IB and II will be restricted to carriage on cargo aircraft. All packages must bear the Cargo Aircraft Only label in addition to the other marks and labels required by the Regulations.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

OSHA hazard communication standard (29 CFR 1910.1200): Non-hazardous

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lithium-Ion Rechargeable Battery Pack?

The signal word is no signal word.

What is the physical form of Lithium-Ion Rechargeable Battery Pack?

Lithium-Ion Rechargeable Battery Pack is a solid .