Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lithium-Ion Rechargeable Battery Pack
- Product Code
- BL1021B
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Makita U.S.A., Inc.
manufacturer
14930-C Northam Street La Mirada, CA 90638
1-510-657-9881
Emergency Contacts
CHEMTREC
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Battery Cell; Circuit Module; Plastic Parts and Paints
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Aluminum Foil | 7429-90-5 | 2 - 10% | Yes |
| Metal Oxide (proprietary) | --- | 20 - 50% | Yes |
| Polyvinylidene Fluoride (PVDF) | 24937-79-9 | 5% | Yes |
| Copper Foil | 7440-50-8 | 2 - 10% | Yes |
| Carbon (proprietary) | 7440-44-0 | 10 - 30% | Yes |
| Electrolyte (proprietary) | --- | 10 - 20% | Yes |
| Stainless steel, Nickel and inert materials Remainder N/A | --- | --- | Yes |
| Lead | 7439-92-1 | 0.001% | Yes |
| Mercury | 7439-97-6 | --- | Yes |
| Chromium | 7440-47-3 | --- | Yes |
| Cadmium | 7440-43-9 | --- | Yes |
| Plastic case and Si2O | --- | --- | Yes |
| Lead | 7439-92-1 | 0.1% | Yes |
| Nickle | 7440-02-0 | 0.01% | Yes |
| CFCs | 75-69-4 | --- | Yes |
| Polyclorinated Biphenyls | 1336-36-3 | --- | Yes |
Watt-hour rating: Under 100 WH
First Aid Measures
Emergency procedures for chemical exposure incidents
Leave area immediately and seek medical attention.
Wash area thoroughly with soap and water and seek medical attention.
Rinse eyes with water for 15 minutes and seek medical attention.
If swallowed, obtain medical attention immediately. Drink milk/water and induce vomiting; seek medical attention.
Immediate Medical Attention
Seek medical attention immediately for all exposure routes.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing media suitable for the materials that are burning.
Cell is not flammable but internal organic material will burn if the cell is incinerated. If heated above 125°C, cell(s) can explode/vent.
If possible, remove cell(s) from firefighting area.
Firefighter Protection
Use NIOSH/MSHA approved full-face self-contained breathing apparatus (SCBA) with full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Related Products
Similar products with comparable safety profiles
Lithium-Ion Rechargeable Battery Pack
---
Lithium-Ion Rechargeable Battery Pack
---
Lithium ion Rechargeable Battery Pack
---
Lithium ion Rechargeable Battery
---
Lithium-Ion battery pack
---
Lithium-Ion Rechargeable Battery Pack BL1820B
---
Lithium-Ion Rechargeable Battery Pack BL1820B
---
Lithium-Ion Rechargeable Battery Pack BL1041B
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special protective clothing required for handling individual cells.
Store in a cool, dry place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not required for handling of cells.
Not required beyond safety practices of employer.
Not required during normal operations. SCBA required in the event of a fire.
Steel toed shoes recommended for large container handling.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
heat, open flame
corrosives
None during normal operating conditions. If cells are opened, hydrogen fluoride and carbon monoxide may be released.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of according to all federal, state, and local regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3480, 3481
- Shipping Name
- Lithium-ion batteries
- Transport Class
- 9
- Packing Group
- II
When a number of batteries are transported by ship, vehicle and railroad avoid high temperature and dew condensation. Avoid transportation which may cause damage of package.
When a number of batteries are transported by ship, vehicle and railroad avoid high temperature and dew condensation. Avoid transportation which may cause damage of package.
Lithium ion cells and batteries must be offered for transport at a state of charge not exceeding 30 per cent of their rated capacity. UN 3480, PI 965, Section IA and IB and II will be restricted to carriage on cargo aircraft. All packages must bear the Cargo Aircraft Only label in addition to the other marks and labels required by the Regulations.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
OSHA hazard communication standard (29 CFR 1910.1200): Non-hazardous
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lithium-Ion Rechargeable Battery Pack?
The signal word is no signal word.
What is the physical form of Lithium-Ion Rechargeable Battery Pack?
Lithium-Ion Rechargeable Battery Pack is a solid .