Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lithium-Ion Rechargeable Battery Pack BL1840B
- Product Code
- BL1840B
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Makita U.S.A., Inc.
manufacturer
14930-C Northam Street, La Mirada, CA 90638
1-510-657-9881
Emergency Contacts
CHEMTREC
1-800-424-9300
Day or Night
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The battery pack contains various materials within the cell, including cathode, anode, electrolyte, and enclosure components.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lithium Nickel Cobalt Oxides Manganese Oxides | --- | --- | Yes |
| Polyvinylidene Fluoride | --- | --- | Yes |
| Graphite | --- | --- | Yes |
| Organic Solvent | --- | --- | Yes |
| Lithium Salt | --- | --- | Yes |
| Plastic (PC) | --- | --- | No |
UN number: UN3480. Watt-hour rating: 72Wh for battery pack.
Notes
The battery pack should not be opened or burned since the ingredients contained within the cell could be harmful under some circumstances if exposed or misused. The cell contains neither metallic lithium nor lithium alloy. Heavy metals such as Mercury, Cadmium, Lead, and Chromium are not used in the cell.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air immediately, and call a doctor.
Wash the contact areas off immediately with plenty of water and soap.
Symptoms: sores on the skin
Flush the eyes with plenty of clean water for at least 15 minutes immediately, without rubbing, and call a doctor.
Symptoms: eye irritation
Immediate Medical Attention
Call a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
gas, foam, powder
corrosive gas may be produced at the time of fire extinguishing
Use a large amount of water as a supportive measure in order to get cooling effect if needed. (Indoor/outdoor fire hydrant). Carry away flammable materials immediately in case of fire. Move batteries to a safer place immediately in case of fire.
Firefighter Protection
use an air inhalator when danger is predicted
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wipe off with dry cloth
Materials: dry cloth
Related Products
Similar products with comparable safety profiles
Lithium-Ion Rechargeable Battery Pack BL1840B
---
Lithium-Ion Rechargeable Battery Pack BL1840B
---
Lithium-Ion Rechargeable Battery Pack BL1830B
---
Lithium-Ion Rechargeable Battery Pack BL1850B
---
Lithium-Ion Rechargeable Battery Pack BL1850B
---
Lithium-Ion Rechargeable Battery Pack BL1830
---
Lithium-Ion Rechargeable Battery Pack BL1830
---
Lithium-Ion Rechargeable Battery Pack BL1820B
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not disassemble, alter, or solder. Do not short + and – terminals with metal. Do not open the battery pack. Do not impact, pierce or crush the battery. Use specified charger only.
Store within the recommended limit of -30°C to 45°C (-22°F to 113°F), well-ventilated area. Do not expose to high temperature (60°C/140°F). Since short circuit can cause bum hazard or safety vent to open, do not store with metal jewelry, metal covered tables, or metal belt.
Do not incinerate. Do not short circuit.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate ventilation such as local ventilation system in the storage.
safety glove
safety goggle
Gas mask for organic gases
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
External short-circuit, deformation by crush, high temperature (over 100°C) exposure of the battery may cause generation of heat and ignition.
External short-circuit, deformation by crush, high temperature (over 100°C)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose in accordance with applicable federal, state and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3480, 3481
- Shipping Name
- Lithium-ion batteries
- Transport Class
- 9
- Packing Group
- II
avoid high temperature and dew condensation, Avoid transportation which may cause damage of package
avoid high temperature and dew condensation, Avoid transportation which may cause damage of package
avoid high temperature and dew condensation, Avoid transportation which may cause damage of package
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lithium-Ion Rechargeable Battery Pack BL1840B?
The signal word is no signal word.
What is the physical form of Lithium-Ion Rechargeable Battery Pack BL1840B?
Lithium-Ion Rechargeable Battery Pack BL1840B is a solid appearing as lithium-ion rechargeable cells are set in a resin case. .