Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- VARTA Primary Lithium Button Cell
- Product Form
- Button Cell
- Product Code
- CR1025, CR1216, CR1220, CR1225, CR1616, CR1620, CR1632, CR2016, CR2016-P, CR2025, CR2025-P, CR2032, CR2032-P, CR2320, CR2430, CR2430-P, CR2450, CR2450-P, CR2477, CR 1/3 N
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
VARTA Microbattery GmbH
manufacturer
VARTA-Platz 1, 73479 Ellwangen, Germany
Emergency Contacts
VAC
+49 7961 921 110
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Steel and nickel | --- | 33 - 74% | No |
| Manganese dioxide EC: 215-202-6 | 1313-13-9 | 13 - 40% | Yes |
| Plastic | --- | 3 - 10% | No |
| Propylene carbonate EC: 203-572-1 | 108-32-7 | 10% | Yes |
| 1,2-Dimethoxy ethane EC: 203-794-9 | 110-71-4 | 10% | Yes |
| 1,3-Dioxolane EC: 211-463-5 | 646-06-0 | 5% | Yes |
| Lithium perchlorate EC: 232-237-2 | 7791-03-9 | 5% | Yes |
| Lithium EC: 231-102-5 | 7439-93-2 | 1 - 3% | Yes |
Notes
For full text of hazard statements see section 16. For information to allow safe use: see section 7.
First Aid Measures
Emergency procedures for chemical exposure incidents
Seek for medical assistance.
Remove solid particles immediately. Flush affected areas with plenty of water (at least 15 min). Remove contaminated cloth immediately. Seek for medical assistance.
Flush the eye gently with plenty of water (at least 15 min). Seek for medical assistance.
Drink plenty of water. Avoid vomiting. Seek for medical assistance. Do not let the person who ingested the battery eat or drink until an X-ray can determine if a battery is present.
Symptoms: Swallowing may lead to burns, perforation of soft tissue, and death. Severe burns can occur within 2 h of ingestion.
Immediate Medical Attention
In the event of battery ingestion, seek immediate medical attention at a hospital emergency room.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Metal fire extinction powder, rock salt or dry sand shall be used. In case only water is available, it can be used in large amounts.
Carbon dioxide (CO₂) is not suitable. Water in small quantities may have adverse effects.
Cells may explode and release metal parts. At contact of electrolyte with water traces of hydrofluoric acid may be formed. In this case avoid contact and take care for good ventilation. At contact of charged anode material with water extremely flammable hydrogen gas is generated.
Firefighter Protection
Firefighting clothing and self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In the event of battery rupture, prevent skin contact and collect all released material in a plastic lined container. Bind released ingredients with powder (rock salt, sand).
If battery casing is dismantled, small amounts of electrolyte may leak. Package the battery tightly including ingredients together with lime, sand or rock salt. Then clean with water.
Avoid leached substances to penetrate into the earth, canalization or water.
Then clean with water.
Materials: water
Related Products
Similar products with comparable safety profiles
VARTA Primary Alkaline Manganese Button Cell
---
Lithium primary button cell
---
VARTA rechargeable nickel metal hydride button cells
---
VARTA Ultra Lithium
---
VARTA Rechargeable NiMH Cylindrical Cell
---
VARTA Rechargeable NiMH Batteries
---
Lithium primary cylindrical cell
---
Lithium primary cylindrical cell
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always follow the warning information on the batteries and in the manuals of devices. Only use the recommended battery types. Keep batteries away from children. Keep small cells and batteries which are considered swallowable out of the reach of children. For devices to be used by children, the battery casing should be protected against unauthorized access. Unpacked batteries shall not lie about in bulk. In case of battery change always replace all batteries by new ones of identical type and brand. Do not swallow batteries. Do not throw batteries into water. Do not throw batteries into fire. Avoid deep discharge. Do not short-circuit batteries. Do not recharge primary batteries. Do not open or disassemble batteries.
Keep batteries away from children.
Do not throw batteries into fire.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The data for this section has not been processed yet.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
The data for this section has not been processed yet.
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
When heated above 100 °C the risk of rupture occurs.
heated above 100 °C
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Storage of batteries in original packaging, Coverage of the terminals, Embedding in dry sand
In the European Union, manufacturing, handling and disposal of batteries is regulated on the basis of the Regulation (EU) 2023/1542. Importers and users outside EU should consider the local law and rules.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3090
- Shipping Name
- Lithium Metal Batteries
Regulatory Information
Chemical regulations, safety assessments, and compliance status
VARTA Lithium Button Cells conform to the requirements of the EU Battery Regulation (EU) 2023/1542 and are marked with the crossed bin according to Directive 2006/66/EC. In California, the product requires a Proposition 65 warning for nickel and a perchlorate marking.
International safety standards: UL 1642 (BBCV2.MH13654)
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for VARTA Primary Lithium Button Cell?
The signal word is no signal word.