Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EG COOLANT
Product Code
307D

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Ready to use coolant.

Uses advised against

This product should not be used for other purposes than those specified without the advice of an expert.

Manufacturers & Suppliers

P

PETRONAS LUBRICANTS BELGIUM NV

manufacturer

Ingberthoeveweg 4, B-2630 Aartselaar

+32 (0)3 - 458 12 30

Emergency Contacts

Poisons Centre

+32 (0)70 - 245 245

Nationaal Vergiftigingen Informatie Centrum

+31 (0)30 - 274 88 88

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Acute Tox.

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Inhibitor additives, water.

Chemical Name CAS Number Concentration Hazardous
Ethylene glycol EC: 203-473-3 107-21-1 45 - 55% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Expose affected person to fresh air and obtain medical attention.

Skin contact

Remove contaminated clothes and shoes and rinse thoroughly with plenty of water and soap.

Eye contact

Rinse thoroughly with plenty of water for at least 10 minutes keeping eyelids open.

Symptoms: any pain or redness develops or persists.

Ingestion

Do not induce absolutely vomiting to avoid aspiration into the respiratory tracts.

Immediate Medical Attention

Obtain IMMEDIATE MEDICAL ATTENTION if the product has been swallowed and show label or package.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Avoid production and diffusion of mist and aereosol with utilization of localized ventilation/aspiration or other required precautions. If necessary, adopt all required precaution to avoid product immission in environment (e.g., blasting systems, catch basins, ...).

Hands

Wear suitable gloves in organic substance-proof material (i.e. neoprene, nitrile). Gloves should be changed when they show wear. The kind of gloves and the term of use must be decided from employer with regard to processing and to allow for legislation on personal protection equipment and glove producer's indications. Wear gloves only with clean hands.

Eyes

Chemical goggles and face shield in case of oil splashes.

Respiratory

None required under normal conditions of use. Use approved full face respirator with organic vapour filter cartridge if the recommended exposure limits are exceeded.

Skin/Body

Wear suitable protective clothing (for further information, refer to CEN- EN 14605); change it immediately in case of large contamination and wash it before subsequent use.

Environmental

Refer to technical precautions and also to sections 6.2, 6.3, 7.2, 12 and 13.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Relative Density
---
Colour
FLUORESCENT RED
Evaporation Rate
NOT DETERMINED
Vapor Density
NOT DETERMINED
Appearance
FLUORESCENT RED CLEAR LIQUID
State Under Standard Conditions
---
Solubility
---
Colour Intensity
---
Kinematic Viscosity
---
Odor
NOT DETERMINED
Crystallisation Point
---
Physical State
LIQUID
Lower Explosive Limit
NOT DETERMINED
Partition Coefficient
NOT DETERMINED
Physical State Data
liquid
Voc Content
---
Auto Ignition Temperature
NOT DETERMINED
Cloud Point
---
Form
CLEAR LIQUID
Odor Threshold
NOT DETERMINED
Decomposition Temperature
NOT DETERMINED
Flammability
NOT APPLICABLE
Metal Corrosion
---
Relative Evaporation Rate
---
Boiling Point
109C
Softening Point
---
Molecular Weight
---
Upper Explosive Limit
NOT DETERMINED
Freezing Point
-37C
Bulk Density
---
Vapor Pressure
NOT DETERMINED
Melting Point
NOT DETERMINED
Properties Status
---
Solubility In Fat
---
Flash Point
NOT DETERMINED
Solubility In Water
COMPLETELY SOLUBLE
Solidification Point
---
Density
1.070 G/CM
Ph
7.9
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EG COOLANT?

The signal word is na: r-phrases.

What is the physical form of EG COOLANT?

EG COOLANT is a liquid appearing as fluorescent red clear liquid with fluorescent red color. It has not determined odor.

What is EG COOLANT used for?

Ready to use coolant.

What is the melting point of EG COOLANT?

The melting point is NOT DETERMINED and the boiling point is 109C.