Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Coolant BA15-eVo
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Coolant
Uses advised against
No information available.
Manufacturers & Suppliers
EWS GmbH
manufacturer
Siemensstrasse 89A, D-47574 - Goch
+49 (0) 2823 879960
Emergency Contacts
GIZ-Nord
+49(0) 551 - 1 92 40
24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of water, propyleneglycol and inhibitors.
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air.
Wash with plenty of water. Take off contaminated clothing and wash it before reuse.
Rinse immediately carefully and thoroughly with eye-bath or water.
Rinse mouth immediately and drink plenty of water.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Co-ordinate fire-fighting measures to the fire surroundings.
Non-flammable.
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter into surface water or drains.
Absorb with liquid-binding material
Materials: sand, diatomaceous earth, acid- or universal binding agents
Related Products
Similar products with comparable safety profiles
EG COOLANT
---
7794 - Coolant BS 6580
---
Kroon-Oil Coolant SP 12 EVO
UFI: HP60-79J0-G000-MWMC
7795 - Coolant LL G11 VW 774C
---
Antifreeze/Coolant HT-FVA
UFI: DEX5-QFEF-A100-06EK
B PG COOLANT
UFI: 878V-2566-C995-CP34
DEVELON EG COOLANT
UFI: CK8V-25XS-K995-01ED
Coolant VCS ready mixed mix 40/60
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures are necessary.
Keep container tightly closed.
No special fire protection measures are necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Breakthrough times and swelling properties of the material must be taken into consideration. Suitable material: NBR (Nitrile rubber). (DIN EN 374) Thickness of the glove material: >= 0,11 mm Breakthrough time (maximum wearing time): > 480 min
goggles
In case of inadequate ventilation wear respiratory protection. Generation/formation of aerosols: Combination filtering device (EN 14387), Filtering device (full mask or mouthpiece) with filter: A2 P2;Colour:brown, white
Wear suitable protective clothing.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under storage at normal ambient temperatures.
No hazardous reaction when handled and stored according to provisions.
No known hazardous reactions.
No information available.
No known hazardous decomposition products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Coolant BA15-eVo?
The signal word is no signal word.
What is the physical form of Coolant BA15-eVo?
Coolant BA15-eVo is a liquid with colourless color. It has characteristic odor.
What is Coolant BA15-eVo used for?
Coolant
What is the melting point of Coolant BA15-eVo?
The melting point is not determined DIN 53181 and the boiling point is not determined.