Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MasterEmaco P 5000AP
- Synonyms
- EMACO NANOCRETE AP
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Product for construction chemicals
Manufacturers & Suppliers
BASF Australia Limited
manufacturer
Level 12, 28 Freshwater Place Southbank, Victoria 3006, AUSTRALIA
+61 3 8855-6600
Emergency Contacts
BASF Emergency Advice Number
1800 803 440
24h
BASF Emergency Advice Number
+61 3 8855 6666
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
modified cement mortar
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cement, portland, chemicals | 65997-15-1 | 50 - 75% | Yes |
| sodium nitrite | 7632-00-0 | 1 - 5% | Yes |
| Quartz (SiO2) | 14808-60-7 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation of dust. Keep patient calm, remove to fresh air. If difficulties occur: Obtain medical attention.
After contact with skin, wash immediately with plenty of water and soap. Under no circumstances should organic solvent be used. If irritation develops, seek medical attention.
Wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist.
Rinse mouth immediately and then drink plenty of water, seek medical attention. Do not induce vomiting unless told to by a poison control center or doctor.
Medical Treatment
Treat according to symptoms (decontamination, vital functions)
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The extinguishing agents normally used are sufficient.
Product is not combustible or explosive. No particular hazards known.
fire extinguishing method of surrounding areas must be considered.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not discharge into drains/surface waters/groundwater.
Sweep/shovel up.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid dust formation. The Cement contained in this product reacts alkaline when in contact with water or humidity. This may cause severe irritation of skin or mucous membranes. The humidity of the skin or mucous membranes is enough for this reaction. Prolonged direct contact to the dry product should be avoided therefore. Avoid inhalation of dusts. Avoid skin contact. Pour downwind and allow as little free fall as possible while emptying bags into equipment. Breathing must be protected when large quantities are decanted without local exhaust ventilation.
Containers should be stored tightly sealed in a dry place.
Avoid skin contact.
No special precautions necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
nitrile coated cotton gloves (e.g. EN 388, 374)
Tightly fitting safety goggles (splash goggles) (e.g. EN 166)
Breathing protection if dusts are formed.
Body protection must be chosen based on level of activity and exposure., light protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable if stored and handled as prescribed/indicated.
The product is stable if stored and handled as prescribed/indicated.
See MSDS section 7 - Handling and storage.
strong bases, strong acids
No hazardous decomposition products if stored and handled as prescribed/indicated.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Residues should be disposed of in the same manner as the substance/product.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is MasterEmaco P 5000AP known by?
MasterEmaco P 5000AP is also known as: EMACO NANOCRETE AP
What is the hazard signal word for MasterEmaco P 5000AP?
The signal word is danger.
What is the physical form of MasterEmaco P 5000AP?
MasterEmaco P 5000AP is a powder with unspecified color. It has characteristic odor.
What is the solubility of MasterEmaco P 5000AP?
not soluble
What is MasterEmaco P 5000AP used for?
Product for construction chemicals
What are the hazard statements for MasterEmaco P 5000AP?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
What is the melting point of MasterEmaco P 5000AP?
The melting point is > 1,000 °C and the boiling point is not applicable.