NextSDS Logo
Ma

MasterEmaco P 5000AP

DANGER solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MasterEmaco P 5000AP

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Product for construction chemicals

Overview

MasterEmaco P 5000AP commonly used product for construction chemicals.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4
Skin Irr. Category 2
Eye Dam. Category 1
STOT SE Category 3

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • Dispose of contents/container to hazardous or special waste collection point.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BASF Australia Limited

manufacturer

๐Ÿ“

Level 12, 28 Freshwater Place Southbank Victoria 3006, AUSTRALIA

๐ŸŒ

AU

๐Ÿ“ž

+61 3 8855-6600

๐Ÿ“ 

+61 3 8855-6511

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

BASF

๐Ÿ“ž

1800 803 440

๐ŸŒ

AU

๐Ÿ•’

24h

๐Ÿ’ก

within Australia

BASF

๐Ÿ“ž

+ 61 3 8855 6666

๐ŸŒ

AU

๐Ÿ’ก

outside Australia

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

modified cement mortar

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Cement, portland, chemicals 65997-15-1 50-75% โš ๏ธ Hazardous
sodium nitrite 7632-00-0 1-5% โš ๏ธ Hazardous
Quartz (SiO2) 14808-60-7 0.1-1% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Keep patient calm, remove to fresh air.

Symptoms:

difficulties

๐Ÿ–๏ธ Skin Contact

wash immediately with plenty of water and soap.

Symptoms:

irritation

๐Ÿ‘๏ธ Eye Contact

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth immediately and then drink plenty of water.

๐Ÿšจ Immediate Medical Attention Required

Obtain medical attention if difficulties occur (inhalation), if irritation develops (skin), consult an eye specialist (eyes), or seek medical attention (ingestion).

Medical Treatment

Treat according to symptoms (decontamination, vital functions).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
unspecified
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
powder
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
Not determined due to potential health hazard by inhalation.
๐Ÿงช Ph
approx. 11
๐ŸงŠ Melting Point
- 1,000 C
Critical Property
๐Ÿ’จ Boiling Point
not applicable
Critical Property
๐Ÿ”ฅ Flash Point
not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
The product is a non-volatile solid.
๐Ÿ’จ Vapor Pressure
The product has not been tested.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
1,800 kg/m3
โš–๏ธ Density
not available
Critical Property
๐Ÿ”ฅ Flammability
not flammable
๐Ÿ“Š Upper Explosive Limit
As a result of our experience with this product and our knowledge of its composition we do not expect any hazard as long as the product is used appropriately and in accordance with the intended use.
๐Ÿ“Š Lower Explosive Limit
As a result of our experience with this product and our knowledge of its composition we do not expect any hazard as long as the product is used appropriately and in accordance with the intended use.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not applicable
๐Ÿ“Š Decomposition Temperature
No decomposition if stored and handled as prescribed/indicated.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
dispersible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
not applicable, the product is a solid
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

nitrile coated cotton gloves (e.g. EN 388, 374)

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles (splash goggles) (e.g. EN 166)

๐Ÿ˜ท Respiratory Protection

Breathing protection if dusts are formed.

๐Ÿฆบ Skin/Body Protection

Body protection must be chosen based on level of activity and exposure., light protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MasterEmaco P 5000AP?

The signal word for this substance is "danger".

What is the physical form of MasterEmaco P 5000AP?

MasterEmaco P 5000AP is a solid with unspecified color. It has characteristic odor.

What is MasterEmaco P 5000AP used for?

Product for construction chemicals

What is the melting point of MasterEmaco P 5000AP?

The melting point is - 1,000 C and the boiling point is not applicable.