Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ManVer® 2 Hardness Indicator
- Product Code
- 92899
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory reagent. Hardness determination.
Uses advised against
Consumer use.
Manufacturers & Suppliers
Hach Company
manufacturer
P.O.Box 389 Loveland, CO 80539 USA
+1(970) 669-3050
Emergency Contacts
Emergency Contact
+1(303) 623-5716
24 Hour Service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air.
Wash with soap and water. In the case of skin irritation or allergic reactions see a physician.
Symptoms: May cause an allergic skin reaction.
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a physician.
Clean mouth with water and drink afterwards plenty of water.
Medical Treatment
May cause sensitization in susceptible persons. Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Caution: Use of water spray when fighting fire may be inefficient.
Product is or contains a sensitizer. May cause sensitization by skin contact.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes or clothing. Keep people away from and upwind of spill/leak. Ensure adequate ventilation. Use personal protective equipment as required. Evacuate personnel to safe areas.
See Section 12 for additional ecological information.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
In case of insufficient ventilation, wear suitable respiratory equipment. Do not eat, drink or smoke when using this product. Take off contaminated clothing and wash before reuse. Avoid contact with skin, eyes or clothing. Handle in accordance with good industrial hygiene and safety practice.
Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up. Keep out of the reach of children.
Do not eat, drink or smoke when using this product. Take off contaminated clothing and wash before reuse. Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Showers, Eyewash stations, Ventilation systems.
Wear suitable gloves. Gloves must be inspected prior to use. The selected protective gloves have to satisfy the specifications of EU Directive 2016/425 and the standard EN 374 derived from it. Chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374-1:2016.
Wear safety glasses with side shields (or goggles).
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required. Wear breathing apparatus if exposed to vapors/dusts/aerosols.
Wear suitable protective clothing.
Local authorities should be advised if significant spillages cannot be contained. Do not allow into any sewer, on the ground or into any body of water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Not applicable.
None under normal processing. Hazardous polymerization: None under normal processing.
None known based on information supplied.
Strong oxidizing agents, strong acids, and strong bases.
Hydrogen chloride. Sodium monoxide. Nitrogen oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Work in an approved fume hood. Dilute material with excess water making a weaker than 5% solution. Adjust to a pH between 6 and 9 with an alkali, such as soda ash or sodium bicarbonate. If permitted by regulation. Open cold water tap completely, slowly pour the reacted material to the drain. Allow cold water to run for 5 minutes to completely flush the system. Check with local municipal and state authorities and waste contractors for pertinent local information regarding the proper disposal of chemicals.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ManVer® 2 Hardness Indicator?
The signal word is warning.
What is the physical form of ManVer® 2 Hardness Indicator?
ManVer® 2 Hardness Indicator is a solid appearing as powder with red color. It has odorless odor.
What is the solubility of ManVer® 2 Hardness Indicator?
No data available
What is ManVer® 2 Hardness Indicator used for?
Laboratory reagent. Hardness determination.
What are the hazard statements for ManVer® 2 Hardness Indicator?
This substance has 3 hazard statements:
- H317: May cause an allergic skin reaction
- H351: Suspected of causing cancer
- H373: May cause damage to organs through prolonged or repeated exposure
What is the melting point of ManVer® 2 Hardness Indicator?
The melting point is 151 °C / 303.8 °F and the boiling point is No data available.