NextSDS Logo
Safety Data Sheet EN

Isopropanol 99%

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Isopropanol 99%

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Alcohol solvent.

Manufacturers & Suppliers

Nexeo Solutions LLC logo

Nexeo Solutions LLC

manufacturer

3 Waterway Square Place Suite 1000 Woodlands, Tx. 77380 United States of America

1-855-429-2661

www.nexeosolutions.com

Emergency Contacts

Emergency Contact

1-855-NEXEO4U (1-855-639-3648)

Emergency Contact

1-855-NEXEO4U (1-855-639-3648)

CHEMTREC

800.424.9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Eye Irrit. Cat. 2A H319
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapour.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
P264 Wash skin thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/ eye protection/ face protection.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
Isopropyl alcohol 67-63-0 90 - 100% Yes
Ethanol 64-17-5 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious place in recovery position.

Skin contact

If on skin, rinse well with water. If on clothes, remove clothes.

Eye contact

Immediately flush eye(s) with plenty of water. Keep eye wide open while rinsing.

Ingestion

Keep respiratory tract clear.

Immediate Medical Attention

Consult a physician after significant exposure. If eye irritation persists, consult a specialist. If symptoms persist, call a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical

Unsuitable media

High volume water jet

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Instructions

Use a water spray to cool fully closed containers.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).

Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid formation of aerosol. Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Open drum carefully as content may be under pressure. Dispose of rinse water in accordance with local and national regulations.

Storage

No smoking. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

No smoking. Take precautionary measures against static discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Tightly fitting safety goggles. Wear face-shield for abnormal processing problems. Eye wash bottle with pure water available.

Respiratory

No personal respiratory protective equipment normally required. In the case of vapor formation, use a respirator with an approved filter.

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the workplace. Wear protective suit for abnormal processing problems.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
liquid
Ph
No data available
Explosive Limits
---
Odor
alcohol-like
Evaporation Rate
1.2
Colour
colourless, clear
Relative Evaporation Rate
---
Odor Threshold
200 ppm
Bulk Density
No data available
State Under Standard Conditions
---
Physical State
liquid
Relative Density
0.79 @ 20 C (68 F)
Cloud Point
---
Physical State Data
liquid
Vapor Pressure
32 mmHg @ 20 C (68 F)
Dynamic Viscosity
2.4 mPa.s @ 20 C (68 F)
Properties Status
---
Auto Ignition Temperature
399 C
Partition Coefficient
log Pow: 0.05 @ 25 C (77 F)
Freezing Point
-88 C (-126 F)
Metal Corrosion
---
Melting Point
-88 C (-126 F)
Solubility
---
Solubility In Fat
---
Voc Content
---
Flammability
No data available
Solubility In Water
completely miscible
Crystallisation Point
---
Flash Point
12 C (54 F)
Lower Explosive Limit
2 %(V)
Density
0.79 g/cm3 @ 20 C (68 F)
Solidification Point
---
Vapor Density
---
Colour Intensity
---
Form
---
Molecular Weight
---
Boiling Point
82 C (180 F)
Kinematic Viscosity
2.6 mm2/s @ 25 C (77 F)
Softening Point
---
Upper Explosive Limit
12.7 %(V)
Decomposition Temperature
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

Vapours may form explosive mixture with air.

Avoid

Heat, flames and sparks.

Incompatible

Aldehydes Chlorine Ethylene oxide halogens isocyanates Strong acids strong oxidizing agents

Decomposition

Carbon monoxide, carbon dioxide and unburned hydrocarbons (smoke).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with all applicable local, state and federal regulations. For assistance with your waste management needs including disposal, recycling and waste stream reduction, contact NEXEO's Environmental Services Group at 800-637-7922.

Disposal

Dispose of in accordance with all applicable local, state and federal regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1219
Shipping Name
Isopropanol
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Isopropanol 99%?

The signal word is danger.

What is the physical form of Isopropanol 99%?

Isopropanol 99% is a liquid appearing as liquid with colourless, clear color. It has alcohol-like odor.

What is Isopropanol 99% used for?

Alcohol solvent.

What are the hazard statements for Isopropanol 99%?

This substance has 3 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Isopropanol 99%?

The melting point is -88 C (-126 F) and the boiling point is 82 C (180 F).

Compliance Scanner

Scan your compliance