NextSDS Logo
Safety Data Sheet EN

Acetic acid, ammonium salt

CAS 631-61-8

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Acetic acid, ammonium salt
Product Code
423270000; 423270020; 423270250; 423275000
Chemical Name
Acetic acid, ammonium salt
Synonyms
Ammonium acetate

Regulatory Identifiers

CAS Number
631-61-8 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

This product does not contain any substance(s) on the Illicit Drug Precursors/Reagents list. This product does not contain any substance(s) subject to Prohibition, Authorization or Restriction. This product does not contain any substance(s) listed on the voluntary National Code of Practice for Chemicals of Security Concern.

Manufacturers & Suppliers

T

ThermoFisher Scientific Australia Pty Ltd

distributor

5 Caribbean Drive, Scoresby VICTORIA 3179, Australia

1300 735 292

Emergency Contacts

CHEMTREC

03 9757 4559

CHEMTREC

+613 9757 4559

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
N/A --- 95% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Get medical attention immediately if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention immediately if symptoms occur for inhalation and skin contact. Get medical attention if symptoms occur for ingestion and eye contact.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

None under normal use conditions.

Hands

Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC, Butyl rubber. Breakthrough time: See manufacturers recommendations. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Eyes

Wear safety glasses with side shields (or goggles) (Australian/New Zealand Standard AS/NZS 1337 - Eye protectors for Industrial applications)

Respiratory

Use an AS/NZS 1716 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained in line with AS/NZS 1715 on the use and maintenance of repiratory devices. Recommended Filter type: Particle filter (or AUS/NZ equivalent). Recommended half mask:- Valve filtering: EN405 or Half mask: EN140 plus filter, EN 141 (or AUS/NZ equivalent)

Skin/Body

Long sleeved clothing

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
State Under Standard Conditions
---
Bulk Density
No data available
Flash Point
136 C / 276.8 F
Explosive Limits
---
Vapor Density
Not applicable Solid
Vapor Pressure
No data available
Decomposition Temperature
No data available
Relative Evaporation Rate
---
Ph
7.0 5 % solution (20C)
Solidification Point
---
Flammability
No information available
Upper Explosive Limit
---
Form
---
Freezing Point
---
Solubility In Water
1480 g/L (20C)
Dynamic Viscosity
---
Lower Explosive Limit
---
Solubility
No information available
Physical State Data
solid
Auto Ignition Temperature
No data available
Density
No data available
Boiling Point
No information available
Metal Corrosion
---
Appearance
White
Colour
White
Odor
Ammonia-like
Evaporation Rate
Not applicable Solid
Relative Density
---
Odor Threshold
No data available
Kinematic Viscosity
---
Colour Intensity
---
Voc Content
---
Solubility In Fat
---
Molecular Weight
77.08
Partition Coefficient
Ammonium acetate -2.79
Softening Point
No data available
Cloud Point
---
Properties Status
---
Physical State
Solid
Melting Point
114 C / 237.2 F
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Acetic acid, ammonium salt known by?

Acetic acid, ammonium salt is also known as: Ammonium acetate

What is the hazard signal word for Acetic acid, ammonium salt?

The signal word is no signal word.

What is the physical form of Acetic acid, ammonium salt?

Acetic acid, ammonium salt is a solid appearing as white with white color. It has ammonia-like odor.

What is the solubility of Acetic acid, ammonium salt?

No information available

What is Acetic acid, ammonium salt used for?

Laboratory chemicals.

What is the melting point of Acetic acid, ammonium salt?

The melting point is 114 C / 237.2 F and the boiling point is No information available.

Compliance Scanner

Scan your compliance