Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Q-Connect Surface & Whiteboard Cleaning Fluid
- Product Code
- KF04552, ZP
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning agent.
Uses advised against
No specific uses advised against are identified.
Manufacturers & Suppliers
Interaction-Connect SA
distributor
296-298 Route De Longwy, L-1940 Luxembourg
+32 93 80 82 48
http://www.opinfo.net
Emergency Contacts
Emergency Contact
+44 1865 407333
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Methoxy-2-propanol EC: 203-539-1 | 107-98-2 | 10 - 30% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
No specific recommendations. If throat irritation or coughing persists, proceed as follows. Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Loosen tight clothing such as collar, tie or belt. Get medical attention if any discomfort continues.
Symptoms: No specific symptoms known. Spray/mists may cause respiratory tract irritation.
No specific recommendations. Rinse with water. Get medical attention if any discomfort continues.
Symptoms: No specific symptoms known. May cause discomfort.
Rinse with water. Get medical attention if any discomfort continues.
Symptoms: No specific symptoms known. May be slightly irritating to eyes.
No specific recommendations. If throat irritation or coughing persists, proceed as follows. Rinse mouth. Get medical attention if any discomfort continues.
Symptoms: No specific symptoms known. May cause discomfort if swallowed.
Immediate Medical Attention
If in doubt, get medical attention promptly. Get medical attention if any discomfort continues (for inhalation, ingestion, skin, and eye contact).
Medical Treatment
Notes for the doctor: Treat symptomatically. Specific treatments: No special treatment required.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product is not flammable. Extinguish with alcohol-resistant foam, carbon dioxide, dry powder or water fog. Use fire-extinguishing media suitable for the surrounding fire.
Do not use water jet as an extinguisher, as this will spread the fire.
Containers can burst violently or explode when heated, due to excessive pressure build-up.
Avoid breathing fire gases or vapours. Evacuate area. Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk. Cool containers exposed to flames with water until well after the fire is out. If a leak or spill has not ignited, use water spray to disperse vapours and protect men stopping the leak.
Firefighter Protection
Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective clothing. Firefighter's clothing conforming to European standard EN469 (including helmets, protective boots and gloves) will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid discharge to the aquatic environment.
Reuse or recycle products wherever possible. Absorb spillage to prevent material damage. Flush contaminated area with plenty of water. Wash thoroughly after dealing with a spillage.
Related Products
Similar products with comparable safety profiles
Whiteboard Cleaner 250ml
---
Lyreco Whiteboard Cleaning Foam Multi Purpose Cleaner
---
Whiteboard Cleaner 250ml Pump Spray
---
Lyreco HFC Free Whiteboard Cleaning Foam Multi Purpose Cleaner
---
Cleaning Fluid
---
WHITEBOARD CLEANER
---
Clear-It Cleaning Solution
---
LYRECO WHITEBOARD FOAM CLEANER 400ML
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep out of the reach of children. Read and follow manufacturer's recommendations. Wear protective clothing as described in Section 8 of this safety data sheet. Keep away from food, drink and animal feeding stuffs. Handle all packages and containers carefully to minimise spills. Keep container tightly sealed when not in use. Avoid the formation of mists.
No specific recommendations.
Wash promptly if skin becomes contaminated. Take off contaminated clothing. Wash contaminated clothing before reuse.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No specific ventilation requirements.
No specific hand protection recommended.
No specific eye protection required during normal use. Large Spillages: Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible.
No specific recommendations. Provide adequate ventilation. Large Spillages: If ventilation is inadequate, suitable respiratory protection must be worn.
Appropriate footwear and additional protective clothing complying with an approved standard should be worn if a risk assessment indicates skin contamination is possible.
Not regarded as dangerous for the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal ambient temperatures and when used as recommended. Stable under the prescribed storage conditions.
There are no known reactivity hazards associated with this product.
No potentially hazardous reactions known.
There are no known conditions that are likely to result in a hazardous situation.
No specific material or group of materials is likely to react with the product to produce a hazardous situation.
Does not decompose when used and stored as recommended. Thermal decomposition or combustion products may include the following substances: Harmful gases or vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
Based on available data the classification criteria are not met for the mixture and its components.
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
1-Methoxy-2-propanol, 2-Methoxypropanol, and Ethanol are not classified as PBT or vPvB according to current EU criteria.
12.6. Other adverse effects
None known.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be minimised or avoided wherever possible. Reuse or recycle products wherever possible. This material and its container must be disposed of in a safe way.
Dispose of waste to licensed waste disposal site in accordance with the requirements of the local Waste Disposal Authority.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
National regulations: Health and Safety at Work etc. Act 1974, The Chemicals (Hazard Information and Packaging for Supply) Regulations 2009 (SI 2009 No. 716), The Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 (SI 2009 No. 1348), EH40/2005 Workplace exposure limits. EU legislation: REACH, CLP, Dangerous Preparations Directive 1999/45/EC, Dangerous Substances Directive 67/548/EEC.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Q-Connect Surface & Whiteboard Cleaning Fluid?
The signal word is no signal word.
What is the physical form of Q-Connect Surface & Whiteboard Cleaning Fluid?
Q-Connect Surface & Whiteboard Cleaning Fluid is a liquid. appearing as liquid. with colourless. color. It has characteristic. odor.
What is the solubility of Q-Connect Surface & Whiteboard Cleaning Fluid?
Not available.
What is Q-Connect Surface & Whiteboard Cleaning Fluid used for?
Cleaning agent.
What is the melting point of Q-Connect Surface & Whiteboard Cleaning Fluid?
The melting point is Not available. and the boiling point is Not available..