NextSDS Logo
Q-

Q-Connect Surface & Whiteboard Cleaning Fluid

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Q-Connect Surface & Whiteboard Cleaning Fluid
Product Code
KF04552, ZP

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaning agent.
Uses Advised Against
No specific uses advised against are identified.

Overview

Q-Connect Surface & Whiteboard Cleaning Fluid is a liquid. substance commonly used cleaning agent..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P102: Keep out of reach of children.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Interaction-Connect SA company logo - Safety Data Sheet supplier organization

Interaction-Connect SA

undefined

๐Ÿ“

296-298 Route De Longwy L-1940 Luxembourg

๐ŸŒ

LU

๐Ÿ“ž

+32 93 80 82 48

๐ŸŒ www.opinfo.net

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 1865 407333

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
1-Methoxy-2-propanol
EC: 203-539-1
107-98-2 10-30% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

No specific recommendations. If throat irritation or coughing persists, proceed as follows. Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Loosen tight clothing such as collar, tie or belt. Get medical attention if any discomfort continues.

Symptoms:

No specific symptoms known. Spray/mists may cause respiratory tract irritation.

๐Ÿ–๏ธ Skin Contact

No specific recommendations. Rinse with water. Get medical attention if any discomfort continues.

Symptoms:

No specific symptoms known. May cause discomfort.

๐Ÿ‘๏ธ Eye Contact

Rinse with water. Get medical attention if any discomfort continues.

Symptoms:

No specific symptoms known. May be slightly irritating to eyes.

๐Ÿฝ๏ธ Ingestion/Swallowing

No specific recommendations. If throat irritation or coughing persists, proceed as follows. Rinse mouth. Get medical attention if any discomfort continues.

Symptoms:

No specific symptoms known. May cause discomfort if swallowed.

๐Ÿšจ Immediate Medical Attention Required

If in doubt, get medical attention promptly. Get medical attention if any discomfort continues (for inhalation, ingestion, skin, and eye contact).

Medical Treatment

Notes for the doctor: Treat symptomatically. Specific treatments: No special treatment required.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Liquid.
๐ŸŽจ Colour
Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
pH (concentrated solution): 6.5-9
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
Not available.
Critical Property
๐Ÿ”ฅ Flash Point
Not available.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
Not available.
๐Ÿ“Š Bulk Density
Not available.
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available.
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available.
๐Ÿ“Š Partition Coefficient
Not available.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available.
๐Ÿ“Š Kinematic Viscosity
Not available.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No specific ventilation requirements.

๐Ÿงค Hand Protection

No specific hand protection recommended.

๐Ÿ‘๏ธ Eye Protection

No specific eye protection required during normal use. Large Spillages: Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible.

๐Ÿ˜ท Respiratory Protection

No specific recommendations. Provide adequate ventilation. Large Spillages: If ventilation is inadequate, suitable respiratory protection must be worn.

๐Ÿฆบ Skin/Body Protection

Appropriate footwear and additional protective clothing complying with an approved standard should be worn if a risk assessment indicates skin contamination is possible.

๐ŸŒ Environmental Exposure Controls

Not regarded as dangerous for the environment.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Q-Connect Surface & Whiteboard Cleaning Fluid?

The signal word for this substance is "no signal word".

What is the physical form of Q-Connect Surface & Whiteboard Cleaning Fluid?

Q-Connect Surface & Whiteboard Cleaning Fluid is a liquid. appearing as liquid. with colourless. color. It has characteristic. odor.

What is the solubility of Q-Connect Surface & Whiteboard Cleaning Fluid?

Not available.

What is Q-Connect Surface & Whiteboard Cleaning Fluid used for?

Cleaning agent.

What is the melting point of Q-Connect Surface & Whiteboard Cleaning Fluid?

The melting point is Not available. and the boiling point is Not available..