Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Cleaning Fluid
- Product Code
- 9972100 / 9972101 / 9972103
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning fluid for safety spectacles
Manufacturers & Suppliers
UVEX ARBEITSSCHUTZ GMBH
manufacturer
Würzburger Strasse 181 - 189, 90766 Fürth, Germany
+49 911 97360
Emergency Contacts
Emergency Contact
+49 911 97360
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propan-2-ol EC: 200-661-7 | 67-63-0 | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Mouth to mouth resuscitation should be avoided. Use alternative methods, preferably with oxygen or compressed air driven apparatus.
Wash with plenty of soap and water.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Do not induce vomiting. Get medical advice/attention if you feel unwell.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. If breathing is irregular or stopped, immediately seek medical assistance. Get medical advice/attention if you feel unwell.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, alcohol resistant foam, fire extinguishing powder, carbon dioxide (CO₂), co-ordinate firefighting measures to the fire surroundings
water jet
Refer to Section 10
Keep containers cool with water spray. Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Wear self-contained breathing apparatus
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate affected area.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Collect spillage.
Materials: Absorbent material (e.g. sand, diatomaceous earth, acid binder, universal binder, sawdust, etc.).
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes.
Keep container tightly closed and in a well-ventilated place. Keep cool. Protect against heat, frost.
Do not eat, drink and smoke in work areas. Wash hands after use.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local and general ventilation.
short-term (single instance): not required fill and mix: wear suitable gloves Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-tightness/impermeability prior to use. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.
short-term (single instance): not required fill and mix: Wear eye glasses with side protection according to EN 166.
In case of inadequate ventilation wear respiratory protection. Type: A-P2 (combined filters against particles and organic gases and vapours, colour code: Brown/White). (EN 136, EN 140, EN 14387, EN 143, EN 149).
fill and mix: Protective clothing against liquid chemicals. (EN 13832, EN 340, EN 14605).
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Needs not be classified as flammable: flash point of more than 35 °C and negative results have been obtained in the sustained combustibility test.
In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
oxidiser
Reasonably anticipated hazardous decomposition products produced as a result of use, storage, spill and heating are not known. Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Cleaning Fluid?
The signal word is no signal word.
What is the physical form of Cleaning Fluid?
Cleaning Fluid is a liquid with colourless color. It has alcohol-like odor.
What is Cleaning Fluid used for?
Cleaning fluid for safety spectacles
What is the melting point of Cleaning Fluid?
The melting point is not determined and the boiling point is 94 °C.