NextSDS Logo
Safety Data Sheet EN

HistoPot - 10% Buffered Formalin

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HistoPot - 10% Buffered Formalin
Product Code
(S) 10-B-FOR-

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fixative for Histology

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

S

Serosep Ltd.

manufacturer

Annacotty Business Park, Annacotty, Co. Limerick, Ireland

+353 61 358190

Emergency Contacts

National Poisons Information Centre, Beaumont Hospital, Dublin 9

01 8092566

8am-10pm (seven days)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Carc. Cat. 1B H350
Skin Sens. Cat. 1 H317
Muta. Cat. 2 H341

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H317 May cause an allergic skin reaction.
H341 Suspected of causing genetic defects.
H350 May cause cancer.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P321 Specific treatment (see on this label).
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
formaldehyde EC: 200-001-8 50-00-0 4% Yes
methanol EC: 200-659-6 67-56-1 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Open and handle receptacle with care.

Storage

No special requirements. Keep container tightly sealed.

Fire prevention

Keep respiratory protective device available.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Nitrile chemical gloves should be used when handling formaldehyde solutions. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles. suitable eye protection, for example, chemical rated safety glasses, goggles or face shield, should be used.

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. If engineering controls cannot provide adequate protection then a certified respirator, fitted with an appropriate chemical vapour cartridge such as an A2B2E2K2P3 rated filter should be used. Users must be trained in the care, use, and replacement of respirators and filters.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Fluid
Colour
According to product specification
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
100 °C
Flash Point
Not applicable.
Freezing Point
Undetermined.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
23 hPa
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
5.00 %
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HistoPot - 10% Buffered Formalin?

The signal word is danger.

What is the physical form of HistoPot - 10% Buffered Formalin?

HistoPot - 10% Buffered Formalin is a fluid appearing as fluid with according to product specification color. It has characteristic odor.

What is HistoPot - 10% Buffered Formalin used for?

Fixative for Histology

What are the hazard statements for HistoPot - 10% Buffered Formalin?

This substance has 3 hazard statements:

  • H317: May cause an allergic skin reaction.
  • H341: Suspected of causing genetic defects.
  • H350: May cause cancer.

What is the melting point of HistoPot - 10% Buffered Formalin?

The melting point is Undetermined. and the boiling point is 100 °C.