Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SUMA REVOFLOW PERFECT A17
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Rinse aid
Uses advised against
Uses other than those identified are not recommended
Manufacturers & Suppliers
Diversey Australia Pty. Limited
undefined
29 Chifley St, Smithfield, NSW, 2164, Australia
1800 647 779
http://www.sealedair.com/
Emergency Contacts
Emergency Contact
1800 033 111
24hrs
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Non-hazardous ingredients are the remainder and add up to 100%.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alcohols, C13-15-branched and linear, butoxylated ethoxylated (monomethyl- and monoethyl-branching/BuO=2,EO=5) EC: 601-137-4 | 111905-53-4 | 3 - 10% | Yes |
| Alcohols, C13-15-branched and linear, butoxylated ethoxylated (monomethyl- and monoethyl-branching/BuO=2,EO=5) EC: 601-137-4 | 111905-53-4 | --- | Yes |
| GLUTARALDEHYDE EC: 203-856-5 | 111-30-8 | --- | Yes |
Notes
For the full text of the H phrases mentioned in this Section, see Section 16. Workplace exposure limit(s), if available, are listed in subsection 8.1.
First Aid Measures
Emergency procedures for chemical exposure incidents
Get medical attention or advice if you feel unwell.
Symptoms: No known effects or symptoms in normal use.
Wash skin with plenty of lukewarm, gently flowing water. If skin irritation occurs: Get medical advice or attention.
Symptoms: Causes irritation.
Immediately rinse eyes cautiously with lukewarm water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention.
Symptoms: Causes severe irritation.
Rinse mouth. Immediately drink 1 glass of water. Get medical attention or advice if you feel unwell.
Symptoms: No known effects or symptoms in normal use.
Immediate Medical Attention
Call Poison Information Center: 13 11 26 (Australia Wide). Get medical attention or advice if you feel unwell or if irritation persists.
Medical Treatment
No information available on clinical testing and medical monitoring. Specific toxicological information on substances, if available, can be found in section 11.
Related Substances
Similar chemicals with comparable safety profiles
Suma Revoflow Pristine Pur-Eco A18
UFI: P4K0-K06T-700A-8EED
Suma Crystal Free A8
UFI: 270H-E1RX-600J-4M2T
Remyflo S 200
---
Hiperflo Turbo Ultimate Dev 2
---
Suma Special Pur-Eco L4
UFI: 1D9A-M06S-Y00V-EA6S
FLUX 19
---
Suma Inox Classic D7
UFI: W784-70HD-9001-D3V4
DOLAFLUX SP 11
UFI: 4CD2-G0H1-D00R-P0Q7
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If the product is diluted by using specific dosing systems with no risk of splashes or direct skin contact, the personal protection equipment as described in this section is not required.
Chemical-resistant protective gloves (EN 374). Verify instructions regarding permeability and breakthrough time, as provided by the gloves supplier. Consider specific local use conditions, such as risk of splashes, cuts, contact time and temperature. Suggested gloves for prolonged contact: Material: butyl rubber Penetration time: >= 480 min Material thickness: >= 0.7 mm Suggested gloves for protection against splashes: Material: nitrile rubber Penetration time: >= 30 min Material thickness: >= 0.4 mm In consultation with the supplier of protective gloves a different type providing similar protection may be chosen.
Safety glasses are not normally required. However, their use is recommended in those cases where splashes may occur when handling the product.
No special requirements under normal use conditions.
No special requirements under normal use conditions.
No special requirements under normal use conditions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SUMA REVOFLOW PERFECT A17?
The signal word is warning.
What is the physical form of SUMA REVOFLOW PERFECT A17?
SUMA REVOFLOW PERFECT A17 is a liquid with clear, blue color. It has product specific odor.
What is SUMA REVOFLOW PERFECT A17 used for?
Rinse aid
What are the hazard statements for SUMA REVOFLOW PERFECT A17?
This substance has 2 hazard statements:
- H315: Causes skin and serious eye irritation.
- H319: Causes skin and serious eye irritation.
What is the melting point of SUMA REVOFLOW PERFECT A17?
The melting point is Not determined and the boiling point is Not determined.