Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Suma Bac D10
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For professional and industrial use only. AISE-P314 - Surface disinfectant. Manual process AISE-P315 - Surface disinfectant. Spray and rinse manual process AISE-P301 - General purpose cleaner. Manual process AISE-P302 - General purpose cleaner. Spray and wipe manual process Disinfectant for closed systems or equipment (AISE_CSP02 & AISE_CSP05)
Uses advised against
Uses other than those identified are not recommended
Manufacturers & Suppliers
Diversey Europe Operations BV
global supplier
Maarssenbroeksedijk 2, 3542DN Utrecht, The Netherlands
Diversey Ltd
national supplier
Weston Favell Centre, Northampton NN3 8PD, United Kingdom
01604 405311
Emergency Contacts
Emergency Contact
0800 052 0185
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS05
GHS09
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 3 - 10% | Yes |
| N/A | --- | 3 - 10% | Yes |
| N/A | --- | 1 - 3% | Yes |
For the full text of the H and EUH phrases mentioned in this Section, see Section 16.
Notes
Workplace exposure limit(s), if available, are listed in subsection 8.1. [1] Exempted: ionic mixture. See Regulation (EC) No 1907/2006, Annex V, paragraph 3 and 4. This salt is potentially present, based on calculation, and included for classification and labelling purposes only. Each starting material of the ionic mixture is registered, as required. [2] Exempted: included in Annex IV of Regulation (EC) No 1907/2006. [3] Exempted: Annex V of Regulation (EC) No 1907/2006.
First Aid Measures
Emergency procedures for chemical exposure incidents
Get medical attention or advice if you feel unwell.
Symptoms: No known effects or symptoms in normal use.
Wash skin with plenty of lukewarm, gently flowing water. Take off immediately all contaminated clothing and wash it before re-use. If skin irritation occurs: Get medical advice or attention.
Symptoms: Causes irritation.
Hold eyelids apart and flush eyes with plenty of lukewarm water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTRE, doctor or physician.
Symptoms: Causes severe or permanent damage.
Rinse mouth. Immediately drink 1 glass of water. Never give anything by mouth to an unconscious person. Get medical attention or advice if you feel unwell.
Symptoms: No known effects or symptoms in normal use.
Immediate Medical Attention
Immediately call a POISON CENTRE, doctor or physician for eye contact. Get medical attention or advice if you feel unwell for inhalation or ingestion. Get medical advice or attention if skin irritation occurs.
Related Substances
Similar chemicals with comparable safety profiles
Suma Bac D10
UFI: 68D4-00Y1-P009-G585
Suma Bac Conc D10 Conc
---
Suma Dip K1
UFI: PV8J-81NA-Q006-RA9M
Suma Star-plus D1 plus
UFI: PUC4-G0H2-400T-5FAU
Suma Inox Classic D7
UFI: W784-70HD-9001-D3V4
Suma Calc D5 Descaler
---
Suma Special Pur-Eco L4
UFI: 1D9A-M06S-Y00V-EA6S
Suma Auto Oven Clean D9.10
UFI: U1FJ-N125-200V-ET8G
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If the product is diluted by using specific dosing systems with no risk of splashes or direct skin contact, the personal protection equipment as described in this section is not required.
Chemical-resistant protective gloves (EN 374). Verify instructions regarding permeability and breakthrough time, as provided by the gloves supplier. Consider specific local use conditions, such as risk of splashes, cuts, contact time and temperature. Suggested gloves for prolonged contact: Material: butyl rubber Penetration time: >= 480 min Material thickness: >= 0.7 mm Suggested gloves for protection against splashes: Material: nitrile rubber Penetration time: >= 30 min Material thickness: >= 0.4 mm In consultation with the supplier of protective gloves a different type providing similar protection may be chosen.
Safety glasses or goggles (EN 166).
No special requirements under normal use conditions.
No special requirements under normal use conditions.
Should not reach sewage water or drainage ditch undiluted or unneutralised.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3267
- Shipping Name
- Corrosive liquid, basic, organic, n.o.s. ( trisodium citrate, alkyldimethylbenzylammoniumchloride )
- Transport Class
- 8
- Packing Group
- III
None known.
None known.
None known.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Suma Bac D10?
The signal word is danger.
What is the physical form of Suma Bac D10?
Suma Bac D10 is a liquid with clear, purple color. It has product specific odor.
What is the solubility of Suma Bac D10?
Fully miscible
What is Suma Bac D10 used for?
For professional and industrial use only. AISE-P314 - Surface disinfectant. Manual process AISE-P315 - Surface disinfectant. Spray and rinse manual process AISE-P301 - General purpose cleaner. Manual process AISE-P302 - General purpose cleaner. Spray and wipe manual process Disinfectant for closed systems or equipment (AISE_CSP02 & AISE_CSP05)
What are the hazard statements for Suma Bac D10?
This substance has 4 hazard statements:
- H290: May be corrosive to metals.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Suma Bac D10?
The melting point is Not determined and the boiling point is Not determined.