Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Fluorescence Mounting Medium commonly used laboratory use container type: bottle gm304 // fluorescence mounting medium // cytology fish accessory kit // 1 x 8 ml k5499 // fluorescence mounting medium // cytology fish accessory kit // 1 x 300 l k5731 // fluorescence mounting medium // her2 fish pharmdx kit // 1 x 0,4 ml k5733 // fluorescence mounting medium // top2a iqfish pharmdx // 1 x 0,4 ml k5736 // fluorescence mounting medium // met iqfish // 1 x 0,4 ml k5799 // fluorescence mounting medium // histology fish accessory kit // 1 x 0,4 ml.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Dako Denmark A/S
undefined
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEMTREC
+(44)-870-8200418
GB
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixtureChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Glycerol EC: 200-289-5 | 56-81-5 | 50-75% | โ Non-hazardous |
Composition Notes
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. There are no ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.
๐๏ธ Skin Contact
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
๐๏ธ Eye Contact
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.
๐ฝ๏ธ Ingestion/Swallowing
Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.
๐จ Immediate Medical Attention Required
Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically. No specific treatment.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
๐งค Hand Protection
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.
๐๏ธ Eye Protection
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
๐ท Respiratory Protection
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.
๐ฆบ Skin/Body Protection
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
๐ Environmental Exposure Controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Fluorescence Mounting Medium?
The signal word for this substance is "no signal word".
What is the physical form of Fluorescence Mounting Medium?
Fluorescence Mounting Medium is a liquid. with not available. color. It has not available. odor.
What is the solubility of Fluorescence Mounting Medium?
Soluble in the following materials: cold water and hot water.
What is Fluorescence Mounting Medium used for?
Laboratory use Container type: Bottle GM304 // Fluorescence Mounting Medium // Cytology FISH Accessory Kit // 1 x 8 mL K5499 // Fluorescence Mounting Medium // Cytology FISH Accessory Kit // 1 x 300 L K5731 // Fluorescence Mounting Medium // HER2 FISH pharmDx Kit // 1 x 0,4 mL K5733 // Fluorescence Mounting Medium // TOP2A IQFISH pharmDx // 1 x 0,4 mL K5736 // Fluorescence Mounting Medium // MET IQFISH // 1 x 0,4 mL K5799 // Fluorescence Mounting Medium // Histology FISH Accessory Kit // 1 x 0,4 mL
What is the melting point of Fluorescence Mounting Medium?
The melting point is Not available. and the boiling point is Not available..