NextSDS Logo
Safety Data Sheet EN

PureSperm® Wash

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PureSperm® Wash
Product Form
sterile isotonic salt solution
Product Code
PSW-100, PSW-020, PSSK-010 (PSW 10 x 6 mL)

Regulatory Identifiers

CAS Number
N/A

Identified Uses

washing the sperm pellet recovered from density gradient preparation, for use in swim-up procedures, extension of sperm prior to IUI or as a maintenance medium

Manufacturers & Suppliers

N

NidaCon International AB

manufacturer

Flöjelbergsgatan 16B, SE-431 37, Mölndal, Sweden

+46 - 31 - 703 06 30

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The product consists of a physiological salt solution containing human serum albumin.

Chemical Name CAS Number Concentration Hazardous
physiological salt solution --- --- No
human serum albumin --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from exposure. Transfer person to fresh air. If discomfort persists, obtain medical attention.

Skin contact

Wash off with an abundance of water and remove contaminated clothing.

Eye contact

After initial flushing with physiological saline, remove any contact lenses. Flush thoroughly with physiological saline for 15 minutes. If discomfort persists, obtain medical attention.

Ingestion

Rinse mouth with water and give water to drink. Never give water to unconscious person.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Unlikely to burn.

Specific hazards

Not applicable.

Firefighter Protection

Use correct equipment applicable to primary cause of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Always follow the community, state or federal regulations.

Cleanup methods

Wipe up using appropriate absorbent material and dispose with normal laboratory refuse, according to community, state or federal regulations.

Materials: appropriate absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid inhaling, ingestion, and contact with eyes and skin.

Storage

Store at room temperature or if opened at +2° to +8°C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Normal ventilation.

Hands

None known

Eyes

None known

Respiratory

None known

Skin/Body

None known

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Properties Status
---
Cloud Point
---
Relative Density
Approx. 1.0
Physical State
Transparent liquid (light yellow)
Metal Corrosion
---
Density
---
Physical State Data
liquid
Solubility
---
Lower Explosive Limit
Not applicable
Softening Point
---
Decomposition Temperature
---
Auto Ignition Temperature
Not applicable
Freezing Point
Approx. 0°C
Solubility In Water
Already water solution
Melting Point
Approx. 0°C
Relative Evaporation Rate
---
Vapor Pressure
Not applicable
Upper Explosive Limit
Not applicable
Molecular Weight
---
Flash Point
Not applicable
Ph
7.3-8.5
Kinematic Viscosity
---
Colour Intensity
---
Bulk Density
---
Boiling Point
Approx. 100°C
Evaporation Rate
---
Partition Coefficient
---
Solubility In Fat
---
Explosive Limits
---
Form
---
Odor
Odourless
Flammability
---
State Under Standard Conditions
---
Crystallisation Point
---
Appearance
Transparent liquid (light yellow)
Colour
light yellow
Voc Content
---
Dynamic Viscosity
---
Solidification Point
---
Vapor Density
---
Odor Threshold
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

None known

Hazardous reactions

Will not occur

Incompatible

None known

Decomposition

Not applicable

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

flush contents with tap water via a drain into the sewage system

Disposal

open container and flush contents with tap water via a drain into the sewage system according to local community, state or federal regulations

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

See hazards identification.

Chemical Safety Assessment Not performed

United States: 510 (k) K984172; EU: EC Certificate 241555-2017-CE-NOR-NA-PS

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PureSperm® Wash?

The signal word is no signal word.

What is the physical form of PureSperm® Wash?

PureSperm® Wash is a transparent liquid (light yellow) appearing as transparent liquid (light yellow) with light yellow color. It has odourless odor.

What is PureSperm® Wash used for?

washing the sperm pellet recovered from density gradient preparation, for use in swim-up procedures, extension of sperm prior to IUI or as a maintenance medium

What is the melting point of PureSperm® Wash?

The melting point is Approx. 0°C and the boiling point is Approx. 100°C.