Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Endo Cold Spray Mint / Orange

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Auxiliary for manufacture of dental prothesis

Manufacturers & Suppliers

H

Henry Schein Inc

manufacturer

135 Duryea Road Melville, NY 11747 USA

H

Henry Schein UK Holdings Ltd

distributor

Medcare House, Centurion Close Gillingham Business Park Gillingham, ME8 0SB U.K.

+44 (0) 1634878750

Emergency Contacts

Chemtrec US

(800) 424-9300

Mo-Fr 0-24 h

Chemtrec

001 703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Pressurized container: Do not pierce or burn, even after use.
P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50 C/122 F.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixtures

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Ethanol anhydrous, denatured with 3% Diethyl Ether EC: 200-578-6 64-17-5 2.5 - 10% Yes
propaan vloeibar gemaakt EC: 200-827-9 74-98-6 50 - 100% Yes
Butane (containing < 0.1 % butadiene (203-450-8)) EC: 203-448-7 106-97-8 25 - 50% Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. As protection from splashes gloves made of the following materials are suitable: Butyl rubber, BR; Nitrile rubber, NBR; Natural rubber, NR.

Eyes

Tightly sealed goggles

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour Intensity
---
Vapor Pressure
5 bar
Softening Point
---
Lower Explosive Limit
1.5 Vol % (Propan/Butan)
Form
Aerosol
Freezing Point
---
Upper Explosive Limit
10.9 Vol % (Propan/Butan)
Decomposition Temperature
---
Partition Coefficient
---
Physical State Data
aerosol
Cloud Point
---
Voc Content
11 %
Metal Corrosion
---
Flammability
Product is not selfigniting.
Molecular Weight
---
Properties Status
---
Flash Point
-97 C
Appearance
---
Explosive Limits
---
Solubility In Water
Not miscible or difficult to mix.
Boiling Point
Not applicable, as aerosol.
Relative Evaporation Rate
---
Density
0.57 g/cm
Auto Ignition Temperature
365 C
Ph
---
Vapor Density
---
Dynamic Viscosity
---
Relative Density
---
Evaporation Rate
---
Odor Threshold
---
Colour
Transparent
Physical State
---
State Under Standard Conditions
---
Crystallisation Point
---
Odor
Characteristic
Solubility
Not miscible or difficult to mix.
Melting Point
Undetermined.
Solidification Point
---
Bulk Density
---
Solubility In Fat
---
Kinematic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Endo Cold Spray Mint / Orange?

The signal word is danger.

What is the solubility of Endo Cold Spray Mint / Orange?

Not miscible or difficult to mix.

What is Endo Cold Spray Mint / Orange used for?

Auxiliary for manufacture of dental prothesis

What are the hazard statements for Endo Cold Spray Mint / Orange?

This substance has 2 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.

What is the melting point of Endo Cold Spray Mint / Orange?

The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..