NextSDS Logo
PO

POWER CLEAN PRO

DANGER Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
POWER CLEAN PRO
Product Code
BDS001838AE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaners - Heavy duty

Overview

POWER CLEAN PRO commonly used cleaners - heavy duty.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Skin Irr. Category 2 H315
Eye Irrit. Category 2 H319
STOT SE Category 3 H336
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurized container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P102: Keep out of reach of children.
  • P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Pressurised container: Do not pierce or burn, even after use.
  • P261: Avoid breathing mist/vapours.
  • P271: Use only outdoors or in a well-ventilated area.
  • Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.
  • P501: Dispose of contents/container (in accordance with related regulations).

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe bvba company logo - Safety Data Sheet supplier organization

CRC Industries Europe bvba

undefined

๐Ÿ“

Touwslagerstraat 1 9240 Zele Belgium

๐ŸŒ

BE

๐Ÿ“ 

+32(0)52/45.00.34

๐ŸŒ www.crcind.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32(0)52/45.60.11

๐ŸŒ

BE

๐Ÿ•’

office hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes,isoalkanes,cyclics,< 5% n-hexane
EC: EC921-024-6
N/A 25-50% โš ๏ธ Hazardous
Hydrocarbons, C7, n-alkanes,isoalkanes, cyclic
EC: EC927-510-4
N/A 25-50% โš ๏ธ Hazardous
acetone
EC: 200-662-2
67-64-1 5-10% โš ๏ธ Hazardous
Carbon dioxide
EC: 204-696-9
124-38-9 5-10% โš ๏ธ Hazardous
Propan-2-ol
EC: 200-661-7
67-63-0 5-10% โš ๏ธ Hazardous

Composition Notes

The full text for all H-statements is displayed in section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison centre or doctor/physician if you feel unwell.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing. Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Wash contaminated clothing before reuse.

Symptoms:

Skin irritation. May cause redness and pain.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.

Symptoms:

Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.

๐Ÿฝ๏ธ Ingestion/Swallowing

In the unlikely event of swallowing contact a physician or poison control centre. Rinse mouth.

Symptoms:

Nausea, vomiting.

๐Ÿšจ Immediate Medical Attention Required

Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.

Medical Treatment

Provide general supportive measures and treat symptomatically. Keep victim under observation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Solvent.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
-94.7 C (-138.5 F) estimated
Critical Property
๐Ÿ’จ Boiling Point
56 - 99 C (132.8 - 210.2 F)
Critical Property
๐Ÿ”ฅ Flash Point
-26.0 C (-14.8 F)
Critical Property
๐Ÿ“Š Freezing Point
-94.7 C (-138.5 F) estimated
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
2.8 (Ether=1)
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
3
๐Ÿ“Š Relative Density
0.71 g/cm3
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
12.8 % estimated
๐Ÿ“Š Lower Explosive Limit
2.5 % estimated
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 200 C (> 392 F)
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
BLANK
๐Ÿ“Š Solubility In Water
Insoluble in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
685 g/l
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Provide eyewash station and safety shower.

๐Ÿงค Hand Protection

When handling the product wear chemical-resistant gloves (standard EN 374). The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. For prolonged or repeated skin contact use suitable protective gloves. Suitable gloves can be recommended by the glove supplier. Full contact: Glove material: Neoprene. Use gloves with breakthrough time of 480 minutes. Minimum glove thickness 0.38 mm.

๐Ÿ‘๏ธ Eye Protection

Use eye protection conforming to EN 166.

๐Ÿ˜ท Respiratory Protection

Chemical respirator with organic vapour cartridge and full facepiece. (Filter type AX)

๐Ÿฆบ Skin/Body Protection

Wear appropriate chemical resistant clothing.

๐ŸŒ Environmental Exposure Controls

Inform appropriate managerial or supervisory personnel of all environmental releases. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS

โš ๏ธ Transport Hazard Class

2.1

๐Ÿ“‹ Packing Group

Not applicable

๐Ÿš› ADR Transport Precautions

Read safety instructions, SDS and emergency procedures before handling.

๐Ÿšข IMDG Maritime Transport Precautions

Read safety instructions, SDS and emergency procedures before handling.

โœˆ๏ธ IATA Air Transport Precautions

Read safety instructions, SDS and emergency procedures before handling.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for POWER CLEAN PRO?

The signal word for this substance is "danger".

What is the physical form of POWER CLEAN PRO?

POWER CLEAN PRO is a liquid. with colourless. color. It has solvent. odor.

What is POWER CLEAN PRO used for?

Cleaners - Heavy duty

What are the hazard statements for POWER CLEAN PRO?

This substance has 6 hazard statements: H222: Extremely flammable aerosol. H229: Pressurized container: May burst if heated. H315: Causes skin irritation. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of POWER CLEAN PRO?

The melting point is -94.7 C (-138.5 F) estimated and the boiling point is 56 - 99 C (132.8 - 210.2 F).