NextSDS Logo
LE

LECTRA CLEAN II

DANGER CO2 propelled liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LECTRA CLEAN II
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaners - Heavy duty

Overview

LECTRA CLEAN II commonly used cleaners - heavy duty.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.

Precautionary Statements

  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe bvba

manufacturer

๐Ÿ“

Touwslagerstraat 1 9240 Zele Belgium

๐ŸŒ

BE

๐Ÿ“ 

+32(0)52/45.00.34

CRC Industries Finland Oy

national supplier

๐Ÿ“

Smedsgatan 3-5 LT4, PL62, 08101 LOJO

๐ŸŒ

FI

๐Ÿ“ž

+358/(19)32.921

CRC Industries France

national supplier

๐Ÿ“

6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex

๐ŸŒ

FR

๐Ÿ“ž

01.34.11.20.00

๐Ÿ“ 

01.34.11.09.96

CRC Industries Deutschland GmbH

national supplier

๐Ÿ“

Sdring 9, D-76473 Iffezheim

๐ŸŒ

DE

๐Ÿ“ž

(07229) 303 0

๐Ÿ“ 

(07229)30 32 66

CRC INDUSTRIES IBERIA S.L.U.

national supplier

๐Ÿ“

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

๐ŸŒ

ES

๐Ÿ“ž

0034/921.427.546

๐Ÿ“ 

0034/921.436.270

CRC Industries Sweden

national supplier

๐Ÿ“

Laxfiskevgen 16, 433 38 Partille

๐ŸŒ

SE

๐Ÿ“ž

0046/31 27 39 91

๐Ÿ“ 

0046/31 706 84 80

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CRC Industries Europe

๐Ÿ“ž

+32(0)52/45.60.11

๐ŸŒ

BE

๐Ÿ•’

(office hours)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C11-13, n-alkanes, isoalkanes, cyclics, < 2% aromatics
EC: 920-901-0
N/A 50-75% โš ๏ธ Hazardous
(2-methoxymethylethoxy)propanol
EC: 252-104-2
34590-94-8 25-50% โš ๏ธ Hazardous
carbon dioxide
EC: 204-696-9
124-38-9 1-5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell.

Symptoms:

Excessive inhalation of solvent vapours may give rise to nausea, headaches and dizziness.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention.

Symptoms:

May cause irritation. Symptoms: redness and pain.

๐Ÿ‘๏ธ Eye Contact

If substance has got into eyes, immediately wash out with plenty of water. If eye irritation persists: Get medical advice/attention.

Symptoms:

May cause irritation. Symptoms: redness and pain.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed do not induce vomiting because of risk of aspiration into the lungs. If aspiration is suspected obtain immediate medical attention.

Symptoms:

After vomiting of swallowed product aspiration into lungs is likely. Solvents may induce chemical pneumonia. Symptoms: sore throat, abdominal pain, nausea, vomiting.

๐Ÿšจ Immediate Medical Attention Required

If eye irritation persists: Get medical advice/attention. If skin irritation occurs: Get medical advice/attention. Call a POISON CENTER or doctor/physician if you feel unwell. If aspiration is suspected obtain immediate medical attention. If you feel unwell, seek medical advice (show the label where possible). If symptoms persist always call a doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
CO2 propelled liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colorless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Solvent.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
180-220 C
Critical Property
๐Ÿ”ฅ Flash Point
61 C (Closed Cup)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
150 (Ether 1)
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0.825 g/cm3 (@ 20C).
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 200 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Insoluble in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1.85 mPa.s (@ 20C).
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation Keep away from heat and sources of ignition Take precautionary measures against static discharges

๐Ÿงค Hand Protection

Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time. Recommended gloves: Nitrile

๐Ÿ‘๏ธ Eye Protection

Wear safety eyewear according to EN 166.

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. recommended respiratory protection: Air purifying respirator equiped with organic gas/vapor cartridge (type A)

๐ŸŒ Environmental Exposure Controls

Avoid release to the environment. Collect spillage.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS

โš ๏ธ Transport Hazard Class

2.1

๐Ÿ“‹ Packing Group

Not applicable.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LECTRA CLEAN II?

The signal word for this substance is "danger".

What is the physical form of LECTRA CLEAN II?

LECTRA CLEAN II is a co2 propelled liquid. with colorless. color. It has solvent. odor.

What is LECTRA CLEAN II used for?

Cleaners - Heavy duty

What are the hazard statements for LECTRA CLEAN II?

This substance has 2 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated.